SPECIFICATIONSAND GENERAL NOTES
0 CONTRACT CONDITIONS
0.1 THE GENERAL CONDITIONS SHALL BEAIA DOCUMENTA201-1997 EDITION,
ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
THEARCHITECT INCLUDED IN THE GENERAL CONDITIONSARE
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
AS FOLLOWS:
3.2 STUDYTHE CONTRACT DOCUMENTS, VERIFY DIMENSIONSAND
FIELD CONDITIONSAND REPORT DISCREPANCIES BEFORE
PROCEEDING WITH CONSTRUCTION.
3.3 SUPERVISE, DIRECTAND COORDINATE THE WORK, WITH SOLE
RESPONSIBILITYAND CONTROL OVER CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCESAND PROCEDURES.
3.7 OBTAINAND PAY FOR THE BUILDING PERMITAND NECESSARY
GOVERNMENTAL FEES, LICENSESAND INSPECTIONS.
3.14 CUTAND PATCH EXISTING SURFACES TO MATCH EXISTING
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALSAND
WORKMANSHIP
10.1 INITIATE, MAINTAINAND SUPERVISE PROJECT SAFETY
PRECAUTIONSAND PROGRAMS, WHICHARE SOLELYTHE
CONTRACTOR'S RESPONSIBILITY
0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
RULESAND REGULATIONS.
0.3 ALL MATERIALSAND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
QUALITY WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
INACCORDANCE WITH THE INTENTIONAND OBJECTIVE OF THE FINISHED
PROJECT
0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
SIZING OF INTERCONNECTING FACILITIES, SUCHAS PIPING, DUCTSAND
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE
SPECIFIED CAPACITIES OF THE EQUIPMENT
0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
ESTABLISHED BYTHE RECOGNIZEDTRADEASSOCIATION HAVING
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
GOVERN THE WORK.
0.6 NOTALL ITEMS INDICATED ON THE DRAWINGSARE INCLUDED IN THESE
SPECIFICATIONS. IN THE CASE OFAN INCONSISTENCY BETWEEN
DRAWINGSAND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
CLARIFIED BYADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY
OF WORK SHALL BE PROVIDED INACCORDANCE WITH THEARCHITECT'S
INTERPRETATION.
0.7 INSTALL EQUIPMENTAND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
O.A ALTERNATES
1 ALTERNATE 1A: PROVIDEALTERNATE COSTTO REPLACE SEALED CONCRETE
SC1 WITH INTEGRAL COLORED CONCRETE TO BE: SCOFIELD, CHROMIX.
2 ALTERNATE 1 B: PROVIDE ALTERNATE COST TO REPLACE SEALED CONCRETE
SC1 WITH ACID STAINED CONCRETE TO BE: SCOFIELD, LITHOCHROME
CHEMSTAIN CLASSIC.
3 ALTERNATE 2: PROVIDE COST FOR CUSTOM BUILT RECEPTION DESK.
4 ALTERNATE 3: PROVIDE COST TO REPLACE SOLID SURFACE SS2 WITH
STARON TEMPEST, FD187 DAPPLE.
1 GENERAL REQUIREMENTS
1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON-REGULAR
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT
1.2 THE CONTRACTOR SHALL COORDINATEAND SCHEDULE WORK BY OTHERS
INCLUDING BUT NOT LIMITED TO TELEPHONEIDATA, SECURITY FURNITURE
AND "FURNISHEDANDIOR INSTALLED" ITEMS. CONTRACTOR SHALL
COORDINATE EXACT LOCATIONSAND SHALL DO THE CUTTING, FITTING,
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
WORK WHICH WILL RECEIVE THE WORK OF OTHERSAS SHOWN OR
REASONABLY IMPLIED BYTHE DRAWINGSAND SPECIFICATIONS.
1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALSAND
WORKMANSHIP
1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THEARCHITECT FOR THE
FOLLOWING ITEMS:
.1 METAL FABRICATIONS.
.2 ARCHITECTURALWOODWORK, INCLUDING TRIMAND CABINETS.
.3 DOORS, FRAMESAND HARDWARE.
.4 SUSPENDEDACOUSTICAL CEILING SYSTEMS ( 6" X 6" ACOUSTICAL
PANEL ).
.5 FLOORINGAND BASE ( COLOR SAMPLES ).
.6 COLD FORMED METAL FRAMING.
.7 PLUMBING FIXTURES (CATELOG CUTS).
.8 PAINT (8" X 1" DRAW DOWN).
.9 WALL FINISHES (COLOR SAMPLES).
.10 HVAC DIFFUSERS, THERMOSTATSAND GRILLES (CATALOG CUTS).
.11 LIGHT FIXTURES ( CATALOG CUTS ).
,12 FIRE EXTINGUISHERS (CATALOG CUTS).
.13 FIRE PROTECTION PLAN.
.14 AWNING (PLAN & CATALOG CUTS).
1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
ELEVATORS, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEATAND
POWER WILL BE PROVIDED BY THE OWNER, SUBJECTTO THE OWNER OR
THE OWNER'SAGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S
AGENT
1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISESAND
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
SHALL PROVIDEAND MAINTAIN NECESSARY COVERINGS, BOARDS,
TEMPORARY PARTITIONS, AND DOORSAS REQUIRED TO PROTECT
EXISTING WORK, MATERIALS,AND FINISHES TO REMAINATTHE JOB SITE.
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES
ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
ADDITIONAL CHARGE TO THE PARTYAFFECTED.
1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICESANDALARMS
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BEALLOWED WITHOUT
PRIORAPPROVALOFTHEARCHITECT IFASUBSTITUTIONISPROPOSED,
SUBMITTHE FOLLOWING INFORMATION:
1.9
1.10
1.11
1.12
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
5
5.1
6
6.1
6.2
6.3
6.4
.1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGSAND DESCRIPTIONS OF
PRODUCTS,AND FABRICATIONAND INSTALLATION PROCEDURES.
.2 PROVIDE SAMPLES WHEREAPPLICABLE OR REQUESTED.
.3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDINGALL
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
ACCOMMODATE THE SUBSTITUTION.
.4 PROVIDEASTATEMENT INDICATING HOWTHE SUBSTITUTION WILL
AFFECTTHE CONTRACT SUMAND CONTRACTTIME.
STORE MATERIALS ON SITE PRIOR TO INSTALLATION,ANDALLOWTIME
FORTHEIRADJUSTMENTTOAVOID SHRINKAGE OR SWELLING.
THE CONTRACTOR SHALL INCLUDE IN HIS BIDAND SHALLARRANGE FOR
HOISTING, CARTING, ELEVATOR SERVICE, STANDARDAND OVERTIME
SERVICES BYTHE BUILDING MANAGEMENTAND OVERTIME CHARGESAND
EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT
REQUIREMENTS.
PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
EXPECTED FROMACOMMERCIAL BUILDING CLEANINGAND MAINTENANCE
PROGRAM INACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
PROVIDE OPERATINGAND MAINTENANCE MANUALS WITH INFORMATION
NECESSARY FOR THE SAFEAND EFFICIENT OPERATION AND
MAINTENANCE OF EQUIPMENTAND OPERATING SYSTEMS CALLED FOR IN
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
INSPECTION, CAREAND MAINTENANCE OR REPAIR OFARCHITECTURAL
PRODUCTSAND FINISHES WHICHARE OTHER THAN BUILDING STANDARD.
DEMOLITION
COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE
EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
BONDINGIPATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW
WORK.
WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
EQUIPMENT, OR REMOVALAND PATCHING, REMOVALAND REPLACEMENT,
OR REMOVALAND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
TO SUCH WORK SHALL HAVEANY EXCESS MATERIALS REMOVED, AND
SURFACES SHALL BE PREPPEDAND FINISHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALSAND
WORKMANSHIP ADJACENT ITEMS SHALL BE REMOVEDAND RELOCATED
TOALLOWSUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
WHERE WORK INCLUDES REMOVALAND RELOCATION, RELATED
MECHANICALAND ELECTRICAL CONNECTIONSAND TERMINATIONS SHALL
BE INCLUDED.
REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
DRAWINGS.
ON EXISTING-CONSTRUCTION-TO-REMAIN, THOROUGHLY REMOVE
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACEAPPLIED
FINISHES, INCLUDING VINYL BASE, CARPETTILES, ETC. CHEMICALSAND
METHODS TO REMOVE THEADHESIVE SHALL BE COMPATIBLE WITH NEW
FINISHES.
EXISTINGACOUSTICAL CEILING GRID, SUPPORT SYSTEMAND TILES SHALL
REMAIN, EXCEPT IN THOSEAREAS DAMAGED DURIING CONSTRUCTION OR
NOTED TO BE REPAIRED.
SAL�AGEAND TURN OVER TO THE OWNERALL REMOVED ITEMS.
REPAIRAND RESTORE DESIGNATED REUSED EXISTING PRODUCTSAS
REQUIRED TO MEET IN FINISHED FORM THE TYPEAND QUALITY OF WORK
IN SCOPE OF CONTRACT
PROVIDEAND MAINTAIN CARPET MATS IN FRONT OFALL BUILDING
DOORWAYS USED BY CONSTRUCTION WORKERS FORACCESS SUCHAS
ELE�ATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
SHALL BE LARGE ENOUGH TO PREVENTTHE HAULINGISPREADING OF DIRT
THROUGH THE BASE BUILDING PREMISESAND ELE�ATOR CABS.
CONTRACTOR SHALL INSPECT, TESTAND DISCONNECT UTILITY SERVICES
AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAPANDIOR �ALVE-
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINEDAS
PLUMBING, H�AC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS.
CONTRACTOR SHALL INDICATE PERMANENTLYABANDONED UTILITIES ONA
RECORD SEPIATO SERVEAS PART OF THE "AS-BUILT" SET
PROVIDE SHORINGAND BRACING, OR SUPPORTTO PREVENTMOVEMENT,
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENTTO BE
DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN.
METAL FABRICATIONS
PROVIDE STEEL FRAMINGAND SUPPORTS FORAPPLICATIONS INDICATED
OR WHICH ARE NOTA PART OF STRUCTURAL STEEL FRAMEWORK, AS
REQUIRED TO COMPLETE WORK.
WOODAND PLASTIC
CONCEALED ROUGH FRAMINGAND BLOCKING: PROVIDE "CONSTRUCTION
GRADE" LUMBER OFANY SPECIES WITH MAXIMUM 19% MOISTURE
CONTENT
PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
EQUIPMENT, PROVIDE FIRE-RETARDANTTREATED PLYWOOD PANELS,APA
C-D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15132".
FIRE-RETARDANTTREATMENT PRESSURE IMPREGNATE LUMBERAND
PLYWOOD WITH FIRE-RETARDANT CHEMICALS TO COMPLY WITH AWPA
C20AND C27, RESPECTIVELYAND IDENTIFY LUMBER WITH
CLASSIFICATION MARKINGACCEPTABLE TOAUTHORITIES HAVING
JURISDICTION.
FINISH CARPENTRYAND MILLWORK: COMPLYWITH "PREMIUM GRADE"AWI
STANDARDS.
.1 PROVIDE SHOP DRAWINGS FOR OWNER;SAPPRO�AL PRIOR
TO FABRICATION.
6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
NEMALD 3AND GP-50 (0.050" NOMINALTHICKNESS).
.1 EDGE TREATMENT SAMEAS LAMINATE CLADDING ON HORIZONTAL
SURFACES.
.2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOPABOVE
ELECTRICAL OR DATA OUTLET LOCATIONS.
6.6
6.7
6.8
6.9
6.10
6.11
7
7.1
7.2
8
8.1
8.2
8.3
8.4
9
9.1
CABINETS: COMPLYWITHAWI SECTION 400AND ITS DIVISION 400B FOR
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
.1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS:
GP-50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP-28
(0.028" NOMINALTHICKNESS); EDGES: GP-28 (0.028" NOMINAL
THICKNESS).
.2 SEMI-EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP-28.
.3 CABINET HARDWARE SCHEDULE:
.1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES"
BY GRASS OR EQUAL.
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER,
#4483 OR EQUALAS MANUFACTURED BY STANLEY
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH
MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUALAS
MANUFACTURED BY STANLEY
.4 DRAWER GLIDES: SIDEAND BOTTOM MOUNTED SLIDES
WITH POSITIVE STOPAND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; #1429 OR EQUALAS
MANUFACTURED BY KNAPE & VOGT
.5 SHELF SUPPORTSAND STANDARDS: ADJUSTABLE SHELF
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION
MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED
SHELVING STANDARDSAS PRODUCED BY KNAPE & VOGT
OR EQUAL.
MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH
PROVISIONS FOR SCRIBINGAS REQUIRED TO MEET BUILT IN CONDITIONS.
DO NOT DELIVER CASEWORKAND FINISH CARPENTRY UNTIL PAINTING,
WET WORKAND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
WORK HAS BEEN COMPLETEDAND HVAC SYSTEMS HAVE BEEN PROPERLY
OPERATING FOR TEN DAYS.
INSTALL CASEWORKAND FINISH CARPENTRY PLUMB, LEVEL, TRUEAND
STRAIGHT WITH NO DISTORTIONS.
JOINTS BEWTEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
WIDTH NOTTO EXCEED 118 U.O.N.
GROMMETSARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
OUTLETS.
JOINT SEALERS
ONE-PART MILDEW RESISTANT SILICONE SEALANT -AT COUNTERS,
FIXTURESAND JOINTS IN TOILET ROOMS:
.1 "DOWCORNING 786"; DOWCORNING CORP
.2 "SCS 1702 SANITARY"; GENERAL ELECTRIC C0.
.3 "863 #345 WHITE"; PECORACORP
.4 "PROGLAZE WHITE"; TREMCO CORP
.5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS
ACRYLIC-EMULSION SEALANT-AT INTERIOR UNLIKEADJOINING
SURFACES:
.1 "CHEM-CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV
.2 "AC-20"; PECORA CORP
.3 "SONOLAC"; SONNEBORN BUILDING PRODUCTS
.4 "TREMCOACRYLIC LATEX 834"; TREMCO, INC.
DOORSAND WINDOWS
INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD SNAP-ON TYPE
STEEL- (ALUMINUM) FRAMES UNLESS NOTED OTHERWISE. COLOR TO BE
SELECTED BY INTERIOR DESIGNER FROM STANDARD COLORS.
INTERIOR DOORS: AWI SECTION 1300 PREMIUM GRADE PRE-MACHINED 5-
PLY PC-5 PARTICLE BOARD SOLID CORE. WOOD VENEER FACES: XXX
.1 MANUFACTURER STANDARD FACTORY PRE-FINISHED
WITH PERFORMANCE EQUALTOAWI STANDARDS SECTION
1500 CONVERSION VARNISH SYSTEM; ATWO-PART CATALYZED
SYSTEM FOR PREMIUM GRADE PERAWI 1500-T-14.
COLOR TO BE SELECTED BYTHEARCHITECT
.2 WARRANTY: LIFETIME WARRANTY ON ALLARCHITECTURAL FLUSH
WOOD DOORS, INCLUDING THOSE DOORS WITH VIEW PANELSAND
LOUVERS. PROVIDE DRAFT COPY OF WARRANTY WITH SUBMITTALS.
DOOR HARDWARE: BUILDING STANDARD WITHADALEVER HANDLE LATCH
AND LOCKSETS.
GLASS: MEETASTM C1036 REQUIREMENTS FOR GLASSANDASTM C1048
REQUIREMENTS FOR HEAT STRENGTHENED GLASS.
FINISHES
GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
9.2 GYPSUM BOARD: PROVIDE 518" THICK REGULARAND TYPE "X" TAPERED
EDGE GYPSUM BOARD WITH GALVANIZED STEELTRIMACCESSORIESAND
JOINT COMPOUND COMPLYING WITHASTM C475. FINISH INACCORDANCE
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
9.3
9.4
9.5
9.6
9.7
9.11
DRYWALL FINISHING:
.1 COMPLY WITH ASTM C 840 STANDARD SPECIFICATION FOR
APPLICATIONAND FINISHING OF GYPSUM BOARD; GA214
RECOMMENDED LEVELS OF GYPSUM BOARD FINISH;AND
GA216-2000APPLICATIONAND FINISHING OF GYPSUM BOARD.
.2 PROVIDE GYPSUM WALLBOARD MINIMUM FINISH LEVELS
MEETING THE CRITERIA ESTABLISHED IN GA214AS FOLLOWS:
LEVEL 1- GYPSUM WALLBOARD PERMANENTLY CONCEALED FROM VIEW
LEVEL 2- GYPSUM WALLBOARD BEHINDAN APPLIED WALLCOVERING, AND
WALLSAND CEILINGS IN MECHANICALAND EQUIPMENT ROOMS.
LEVEL 4- GYPSUM WALLBOARD ON INTERIOR WALLS FORALL TENANT SPACES.
LEVEL 5- GYPSUM WALLBOARD ONALL FINISHED CEILINGSANDALL COMMON
ARE WALLS.
PORCELAIN TILE: INSTALL TILE IN ACCORDANCE WITH TILE COUNCIL OF
AMERICAGUIDELINES.
.1 PROVIDE FACTORYMADE CORNERANDTRIM SHAPES. MAKE
INSIDE CORNERS SQUARE WITH FULL OR CUT FIELD TILES;
OUTSIDE CORNERS WITH CORNER SHAPES; WALL-TO-FLOOR
CORNERS WITH COVE SHAPES, JOINTS TO MATCH UP
CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUEAND FREE FROM
DAMAGED OR SOILED TILES.
.1 COORDINATE PLACEMENT OF MECHANICALAND ELECTRICAL ITEMS
IN CEILING. WHERE CONFLICTS OCCUR, THEARCHITECTURAL
REFLECTED CEILING PLAN SHALL GOVERN.
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADSAND EXIT SIGNS
UNLESS NOTED OTHERWISE.
INSTALL FLOOR FINISH TRANSITION STRIPAT CENTERLINE OF DOOR OR
CASED OPENING UNLESS NOTED OTHERWISE.
.1 INSTALL JOHNSONITE TRIM STRIPSAT DOOR WHERE CARPET
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
CARPET
RESILIENT FLOORING:
.1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILEAT
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
AVOID USE OF CUT WIDTHS LESS THAN 3"AT ROOM PERIMETER.
.2 BASE: FIT JOINTS TIGHTAND VERTICAL ON CONTINUOUS SOLID
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
USEAN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL
HOLESAND LEVELING. ENSURE THAT FLOORSARE LEVEL WITH MAXIMUM
SURFACE VARIATION OF'/" IN 10 FEET, NON-CUMULATIVE.
PAINT USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
PROTECT HARDWARE, PLATESAND SIMILAR TRIM. AFTER PAINT IS DRY
REINSTALL SUCH ITEMS.
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
1. FERROUS METAL:
A. ACRYLIC SEMI-GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #41702 METALCLADACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLAC-WBACRYLIC
SEMI-GLOSS ENAMEL.
2. NON-FERROUS METAL:
A. ACYRLIC SEMI-GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #41702 METALCLADACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WBACRYLIC
SEMI-GLOSS FINISH
3. FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI-GRIP-WB WATER
REDUCIBLEACRYLIC DRY FOG COATING
4. NON-FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI-GRIP-WB WATER
REDUCIBLEACRYLIC DRY FOG COATING.
6. CONCRETE MASONRY UNIT
A. ACYRLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER:1 COAT#52901 BLOXFILACRYLIC LATEX
BLOCK FILLER
2. FINISH: 2 COATS #35XX WONDER TONESACRYLIC
LATEX SATIN ENAMEL.
7. CONCRETE:
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER: 1 COAT#51801 KILSTAIN-WBALL-
PURPOSE PRIMER-SEALER.
2. FINISH: 2 COATS #35XX WONDER TONESACRYLIC
LATEX SATIN ENAMEL.
8. WOOD:
A. ACRYLIC LATEX SEMI-GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT#51701 WONDER-PRIME LATEX
PRIMER-SEALER.
2. FINISH: 2 COATS #83XX MIRROLAC-WBARCYLIC
SEMI-GLOSS ENAMEL.
B. STAIN-�ARNISH RUBBED FINISH:
1. FILLER: 1 COAT #4800 WONDER WOODSTAIN
PASTE WOOD FILLER (OPEN GRAIN WOODS).
2. STAIN: 1 COAT #96XX WONDER WOODSTAIN
ALKYD STAIN.
3. SEALER: 1 COAT #4900 WONDER WOODSEALER
QUICKDRYSEALER.
4. FINISH: 2 COATS #4600 WONDER WOODSTAIN
ALKYD SATIN �ARNISH.
10. GYPSUM WALLBOARD:
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER: 1 COAT#50801 WONDERTONESLATEX
PRIMER-SEALER.
2. FINISH: 2 COATS #35XX WONDER TONEACYRLIC
LATEX SATIN ENAMEL.
11. CONCRETE FLOORS:
A. ACRYLIC LATEX ENAMEL SATIN FINISH:
1. PRIMER: 1 COAT#78XX LATEX PORCHAND FLOOR
ENAMELTHINNED 20%.
2. FINISH: 2 COATS #78XX LATEX PORCH AND
FLOOR ENAMEL.
12. WOOD FLOORS:
A, ACRYLIC LATEX ENAMEL SATIN FINISH:
1. PRIMER: 1 COAT#51701 WONDER-PRIME LATEX
PRIMER-SEALER.
13. PRECAST CONCRETE:
A, LATEX TEXTURE COATING-SAND FINISH (WETAREAS)
1. PRIMER: 1 COAT#1502WONDER-SHIELDACRYLIC
LATEX HOUSE PAINT PRIMER.
2. FINISH: 1 COAT#44101 DEVVO-TEXLATEX
TEXTURE COATING.
10 SPECIALTIES
10.1 FIRE EXTINGUISHERSAND CABINETS: BUILDING STANDARD, OR IF NO
BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES,
SEMI RECESSED, DUO-PANEL, FIELD PAINTED.
12 FURNISHINGS
12.1 CASEWORK:
.1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
FOLLOWING:
.1 IMPERIAL CABINET CO., INC.
.2 MERILLAT INDUSTRIES, INC.
.3 YORKTOWNE CABINETS
15116
15116.0
15116.3
15116.4
15116.6
15116.7
15116.8
15116.9
15116.10
15116.11
15116.12
15116.13
GN
GN.1
GN.2
GN.3
GN.4
GN.5
GN.6
GN.7
GN.8
GN.9
GN.10
MECHANICALAND ELECTRICAL
MEP SHELL SPECIFICATIONS: IN ADDITION TO THE NOTES BELOW
,
THE PREVIOUSLY ISSUED SPECIFICATION FOR DIVISION 15AND 16
SHALL BEAPPLICABLE TOALL WORK UNDER THESE CONTRACT DOCUMENTS.
COPIES OF THE SPECIFICATIONAREAVAILABLE FROM THEARCHITECT (PEDCOR
DESIGN GROUP)AND THE GENERAL CONTRACTOR (SIGNATURE CONSTRUCTION).
IN CASE OF CONFLICT BETWEENARCHITECT'SAND ENGINEER'S
DRAWINGS IN LOCATION OF TERMINAL MATERIALSIEQUIPMENT, SUCHAS
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
AND SURFACE MOUNTED ELECTRICAL DEVICES, THEARCHITECTURAL
DRAWINGS SHALL GOVERN. NOTIFYARCHITECT OF DISCREPANCIESAND
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATIONIAPPROVAL BYTHE
OWNER OR THE OWNER'SAGENT PATTERN OF SPRINKLER LAYOUT
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUTAND SHALL
COORDINATE WITH OTHER CEILING COMPONENTS.
OUTLETIJUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED
WITH THE EQUIPMENTIAPPLIANCE FOR WHICH IT WAS DESIGNATED.
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
EQUIPMENT
SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
DATAAND COMMUNICATION CABLESARE PROVIDED BY OTHERSAND
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATEATTHE BEGINNING OF THE PROJECT WITH THE TENANTAND
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
INSTALLATION SHALL OCCUR.
DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
OUTLETS, UNLESS OTHERWISE NOTED.
ALL SWITCHESAND SWITCHPLATES SHALL BE BUILDING STANDARD
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
WHITE.
WHERE FLOOR MONUMENTSARE SHOWN NEXT TO EACH OTHER, THEY
SHALL BE LOCATEDAS CLOSE TOGETHERAS POSSIBLE, WHILE STILL
PROVIDING PROPERACCESS TO RECEPTACLES.
IFADDITIONALOUTLETS REQUIRED, COORDINATE WITHARCHITECTURAL
FOR SPECIFIC LOCATION.
CONTRACTOR SHALL MARKALL POWERAND COMMUNICATION OUTLET
LOCATIONS ON SLABAND PROVIDEACCESS TO SITE FORARCHITECTTO
OBSERVE PRIOR TOANY COMMENCEMENT OF "ROUGH-IN"
CONSTRUCTION.
GENERALNOTES
CONTRACTOR TO VERIFY DIMENSIONSAND EXISTING CONDITIONSAND
REPORTANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
PROCEEDING WITH CONSTRUCTION.
DIMENSIONSAREAS FOLLOWS, UNLESS OTHERWISE NOTED:
A. TO FACE OF STUD.
B. TO INSIDE FACE OF JAMBAT DOORSAND OTHER OPENINGS.
C. TO TOP OF FINISHED FLOORS.
D. TO BOTTOM OF FINISHED CEILINGS.
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EXISTING CONSTRUCTIONAND WALLTYPES.
TERMINATE WALLSAT UNDERSIDE OF CEILING UNLESS INDICATED
OTHERWISE.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
LOCATIONS, DIMENSIONSAND TYPES, DOORAND WINDOW LOCATIONS
SHALL BEAS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
FOR THEARCHITECT'S OBSER�ATION WITH REGARD TO DESIGN INTENT
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
OBSER�ATION.
FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMITED TOAPPLIANCESAND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT �ARY BY MORE THAN �/4' IN 20'-0" NON-
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED.
CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CLOSE-IN OF WALLS.
SOUND INSULATEDAND FIRE RATED PARTITIONING SHALL BE CAULKEDAT
PERIMETER WITHACOUSTICAL OR FIRE RATED SEALANTASAPPLICABLE.
PLACE SEALANT BETWEEN GYPSUM BOARDANDADJACENT SUBSTRATE.
PROVIDE WITH SOUNDATTENUATING INSULATION SECURELY FASTENED
TO STUD FRAMING. ATTHESE PARTITIONS, BACKTO BACK ELECTRICAL
JUNCTION BOXESARE NOT PERMITTED.
ALLAPPLIANCES NOTED ON ELE�ATIONS SHALL BE SUPPLIED BY
CONTRACTOR.
PEDGOR DESIGN GROUP ��C
Architecture / Project Management:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
Arch itect:
��������, ,, ,, � � ti t� � � � � � r� r r� �. ,�, ,� ,,, �� ,�����
<'
� �,�
�
�
�
�
�
�
�
�
�r. �K` C�� 5 T �;�' ,�' .��.
� � �� �� � �
� ''� -.
�
� ����� � �� �
� ,�
� $
�
% STATE �}F �
��
�
°��,,�, �'�1��AN � ���`��,
���'�'��`�'ir��'�����G�' ;.1��������
By: �
E H
1 11
r
0
KEY PLA
BLDG B
SC�IL��NtS
z
��?
�--(2
�1E
�
�
�i
,
�- - ..-
�; � � �;
Project:
�
�
� M
�
r
W �
� N
W ' }' `�
� � �
J �^ �
� v� �
�� � �
� U �
4) � .�
� �
� �
z � ^
�1 � -
�� � �
� ■ � �
� �
�,n c�
� �
U
� �
M
�
�
�
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THEARCHITECTAND PEDCOR DESIGN GROUP, LLC. ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINALAND
UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,
MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE
SPECIFICAND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.
STUTZMAN AND PEDCOR DESIGN GROUP, LLC. OO COPYRIGHT 2012
JAMES R. STUTZMAN, AIA, Carmel, Indiana.
STATE RELEASE SET
Issue Date Drawn By Checked By
11.30.12 AJR MC
Revisions:
STATE RELEASE SET - 11.30.12
Project Number:
Sheet Title:
SPECIFICATIONS
Sheet Number:
� �
�
� •