Loading...
HomeMy WebLinkAboutplan-plans-08_A1.0 Architectural Plans.PDF2� — 19 — 18.1 — 18 — — L � L.5 r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -------- -------------- �� � I II I �� �� �� I �� �� TE RM I NATE ' ' �� CONTROL JOINT AT � � i SERVICE CORRIDOR I � � �� e.,:..... . CORNER OF WALL � � I � � ------ �� I ii � �� �� �� I - �� M I I I I ° � I I � I I � �� � ALIGN W/ ' ' ; SUITE 113A CENTERLINE OF i i � i 735 SQ.FT. COLUMN i i � �i � �i i i� _ � � � � � � � � � � � I� � POWER DIST. RM M I I ' II �L------ ------- I I I �--- -------- -------i ALIGN W/ WALL � i i � i � i �i I i I , i I i I II I � i i i I �i i � i ii I i o i I I _ L----------s------� �----------z----�-i N I °I I I � I � II � - - 13'�1►'8" 7'-8 1 /4" ' i r---- i ii i i i � i ii � i i ii�----------- ---� ----------- � � �r__ � ALIGN W/ ' ' � � � � � �i � CENTERLINE OF I � � � I � COLUMN 7�r- - '� ; i ��, � --�� r��� � � I � ,— �� . � Li J I. �� � .�� . ��. t � --� � � -----�'� ----------------------------- ---- -1-=-1= ------,� h � � I i � i i � � � I I � L-- ------- � L`-- / ii �----------------I� �� �, � �, I � �, � �� � �� � � �� �, �, I N � L----, � � � �----, i i _ �_ � ALIGN W/WALL u � _______ —_ I --�---- ---I-- I I I � � ISUITE 113B n COMMON AREA 735 SQ.FT. ;; 747 SQ.FT. I � II IL---------- I - - - - - - - - - INOTE: ENANT BUILD-OUT WALLS & FIXTURES SHOWN W/ DASHED LINE CONTROL JOINTS � � � � I I I � I ` � � � � � � -- = �-�---------- - �, � i� `i� � � � � � � � � :�:.:�:-------------- GENERAL NOTES: 1 USE 1/2" EXPANSION JOINT MATERIAL AGAI NST ALL EXISTING CONCRETE & CMU WALLS AND AROUND ALL COLUMN & PIPE PENETRATIONS. 2 RAMP SLOPES TO BE 1:12 UNLESS NOTED. 3 RAIL POSTS TO BE CORE DRILLED AND EPDXIED. I I ,. M� II L--------+- �� - - -,..� - - - - � �� �� �� I � �� �� I �� �� � �� I � � � �— �� �� � �� I �� I �� �� �� I � �� �� I I I I I I I I I I I I I I I I I I I I � I I � � � II I I 7� I r_� � �r---- ----��=J----- ----� �, � �, -_-�_� �. 3 A1.0 MECH SHAFT Control Joint Layout Plan SCALE: 1 /4" = 1'-0" 0 2' 4' 8' 20 19 18.1 18 L L.5 M I I I NOTES: 1. All penetrations through fire rated walls, floors and roofs shall have U L rated assemblies protecting the spaces at occupied sides. See sheet A3.4 for related assemblies. 2. Tenant's fire alarm shall be connected to the Building fire alarm and include sensors as required for its occupancy and construction type. 3. Reference UL rated wall assemblies for rated walls indicated on the project floor plan, and the life safety plan of the project. 4. Review interior drawings for all wall types. 5. Include finishing (completing) and repairing all existing spray-applied fireproofing, fire sealants and fire stopping that is unfinished or damaged from the shell project into the scope of this tenant improvement. Provide a breakout summary of work required and proportion of the line item affected by these areas and items. 6. All emergency lighting to tenant improvement required to have 2 or more exits shall be connected to the Emergency and Standby Power System (generator). 2 A1.0 I First Floor Plan SCALE: 1 /4" = 1'-0" 0 2' 4' 8' 20 19 18.1 18 — L L.5 M 1 A1.0 I First Floor Sandwich Assembly SCALE: 1 /4" = 1'-0" 0 2' 4' 8' PEDGOR DESIGN GROUP ��C Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Arch itect: `�����������y'�11tt��i t� I I i�Pflllll// ft���/J ✓�r ,�*���`� '��,� � � � � � �����'�,��i �� ����T�,��.� -�''�.;,r .- `� � .� ` � ����� � ��? � = S�ATE �}� f�+'�I A� �` ,;?���I�r�.� By: E H 11 1 r 0 KEY PLA BLDG B SCALE: NTS � , ���;�� � __� � zz _� :. . � PLAN NORTH � � � M � �r � N I..I..I � �= M � � � � � � � � �� � � � U � � � .� � � � � Z � r. � > — �� � � � � � � C� � �� Ca — _ U � � M ti � � COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECTAND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUEDAS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINALAND UNPUBLISHED WORK OF THEARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFICAND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. OO COPYRIGHT 2012 JAMES R. STUTZMAN, AIA, Carmel, Indiana. STATE RELEASE SET IJJUG L.JQLG L.JIQVVII U�/ VIIGIrf�GIA U�/ 11.30.12 JDR/DJS JDR Revisions: STATE RELEASE SET - 11.30.12 Project Number: Sheet Title: Architectural Plans Sheet Number: •