Loading...
HomeMy WebLinkAboutplan-plans-09_A1.1 Fireproofing & Equipment Support Plans.PDFMACHINE LEG, FASTENING BY OTHERS �+48'-0" APPROX Y T/O BEAM, FIELD VERIFY CLEARANCES. ' SUBMIT TO ARCH & MECH ENGINEER SECONDARY EQUIPMENT SUPPORT, SHOWN DASHED, BY MECHANICAL CONTRACTOR EXISTING ROOFING MEMBRANE OVER RIGID INSULATION 3 A1.1 , � W U � C� � 20 19 18.1 — 18 — 6" MIN EXISTING L L.5 M VIBRATION ISOLATION ATALL EQUIPMENT CONNECTIONS TO SUPPORT STRUCTURE, SUBMIT DETAILS TO ARCHITECT GALVANIZED BEAM GALVANIZED HSS POST W/ 1/2" CAP PLATE AND PL 1/2"x5"x9" BASE PLATE W/ (4) HILTI S-MD 12-24x1 1/4 HWH #5 KWI K-COTE. EPDM COMPATIBLE FLASHING BOOT, BY CARLISLE OR EQUAL, SUBMIT DETAILTO ARCHITECT FOR APPROVAL � EXISTI DECK EXISTING BEAM (BEYOND) ROOFTOP EQU I P. SU PPORT: SECTION SCALE:3/4" = 1'-0" 0 1' 2' 3' � 2 A1.1 � PARTIAL ROOF PLAN: N EW ROOFTOP EQU I PM ENT SCALE: 1 /4" = 1'-0" 3 A1.1 GALVANIZED 12' LONG COLD ROLLED W6x16 BEAMS GALVANIZED HSS POST W/ 1/2" CAP PLATE AND PL 1/2"x5"x9" BASE PLATE W/ (4) HILTI S-MD 12-24x1 1 /4 H WH #5 KWI K-COTE. CENTER TUBES & BASE PLATES ON EXISTING BEAMS. 4 A1.1 19 N � '������� ������' -� ------ ---------- � � �U � z ��� I I � .Uz��w zzQ�-z� O-a�zQ� I U�cAm��� I -�----- �------------- —I- I � � � � — �_ ��--�--,,,, I � � � Q I � z ��� I � .Uz��w I zzQ�-z� O-a�zQ� I U�cAm��� I — — �-------------- - — —I--- — — I- � � � � � � -� - �--------------- - -� � '_ 1 fl" �_.��� L.5 0 2' 4' 8' VIBRATION ISOLATION ATALL EQUIPMENT CONNECTIONS TO SUPPORT STRUCTURE, SUBMIT DETAILS TO ARCHITECT SECONDARY EQUIPMENT SUPPORT, SHOWN DASHED, BY MECHANICAL CONTRACTOR CONDENSERS,AS SCHEDULED, REF MECH DRAWI NGS EXISTING MECH CHASE ,' ROOFTOP OPENING. ,' NOTE: REFER TO ,' MECHANICAL PLANS � FOR ADDITIONAL � � ROOFTOP EQUIPMENT �� AND CHASE � � ENCLOSURE DETAILS. ,' SUBMIT CURB DETAILS ' TO ARCHITECT & MECH ENGINEER , . � � , . , . , , , . , . � . � � � � � � � � � � . � � . � . EXISTING ROOF STRUCTURE. REF TO STRUCTURAL DRAWINGS OF EXISTING CONSTRUCTION CONFIRM ACCEPTABILITY OF FINAL SUPPORT STRUCTURE LOCATION W/ MECH. ENGINEER ROOFTOP EQUIPMENT SUPPORT: ENLARGED PLAN SCALE: 1 /2" = 1'-0" 0 1' 2' 4' 20 19 L � I � ' � ' � I � I � � � I � � � � � � � �.,. . �. I � i � � � I � � I I: I: I: �; �: �: �.. I � ,:.�. � � ......; ; fi �; NOTE: FRAMING INDICATED ON PLAN IS � REFLECTED, I.E. EXISTING FRAMING ABOVE SPACE. I FIREPROOFING OF BEAMS & � COLUMNS (EXCLUDING DECKING) IS REQ'D TO COMPLETE UL DESIGN I; N823. COMPLETED ASSEMBLY SHALL PROVIDE THE REQ'D 1 HR I RATED HORIZONTAL SEPARATION ` BETWEEN THIS SPACE I (OCCUPANCY GROUP A-3) & SPACE � � . ABOVE (OCCUPANCY GROUP B). �. 18.1 — — — — — — — — � I, .; 18 — — — — — — — — -�-= . � L.5 . ;♦� � -------------------------------------- - - � - ---------------�—�------------, � � �a � r�� � �a � �� � � a 1 � � �1 1 � a� � a� � '� a � � �� a � I ' �� � �� � '�a � r1 , � a � r� � I W12x19 i ',i i �__=----� ,,, .—.—.—.—.—.—.—.—.—.—.—.— —.—.—. .—.—.—.—.—.—.—.—.—.—.—.—.— i—.—.—.—. � �� � � � � ► � �� , f '► 1 , � , • � 1 1 I ,, , , � %� I � 1 1 ' ' ' ' � � ��1 1 �------'------1 1 �,,,c� � �� � � NOTE: � �, a , "� � '' ! � DECK & BEAMS � ' ► ` x - ��'�, � 'i i i WITHIN THIS ZONE � ��� ��' ���� � � '�� i i j C U R RE NTLY � ',, i,;� I'' � '� � � F I R E P R O O F E D. � I�., . � !�� � �__�__�__..__�,J � , �� a � a ; . W12x19 � '�� i i '�� ► `� I- - - - - - - - - - - - - i •- •- •- •- •- •- •- •- •- •- •- •- •- L •- •- •- • � �� �_— -- --------- � � ',� � --�-- --------- � ���� � � � � �� � � � !� � � � �� � � '� � � 1 '� ► I' •— •— •— •— •— 1 1 •— •— •— •— •— • — •— •— •— •— • 1 I ( ---!---=-- ' ' � � 1 _______ I I ► ' �r � � � If �------------r I -------- � � W12x19 � ',; � � � I ' � ' --�. _ � t� . ' EXP O S E D F RAM I N G— --- —•� • i� j � I (7pening in Rc�t�f Deck for Tenant I (BEAMS & � ,� � t� Mechanical equipment. See Sheet � � `----- � - - , ,��.�. I '' COLUMNS) SHALL � � - - - - - - � . � ' . BE FIREPROOFED � ' � �' � WITHSPRAY � .—.—.—.—.— .—.—.—.—.—. —.—.—.—.—. i'' ► � '' ' � � ' APPLIED FIRE � � � �,! I PROOFING � ► � ' — MATCHING � � � ! � � ' � ' ► � � EXISTING SFRM ON � � � � � '' BLDG. ! ' ' ' i I i ' ' ' ' � '' � � � .. � - - i---------- ---------------- - -------�- �-------� o � '�' � ' . -- = ---------- ---------------- -- ------ - - -------- o _ + � o� i c�i ._ �o o ' � � ' ' ' � 1' � I � � L_ I -------� L' � � � � � �-----------� . . O n I I A\ � � O O U ^ i i i i�i �� i iL L ' 'I �..: I Q� � � . �� �� Q��� N L-----------JIL N O .� O � � N L Q ,� � � (a �• O � �, � Q .�'O— � � � Q-' � (6 O � (6 �i .� � -------------- I � � U U � � ' '� � L Q� �� a� A31 � Q a� � � � � � I LL ��c���c��.� I . � . I 7 � I I A3.1 �/�/14x22 i i W14x22 �'r . I ._._._._._._._._._._._ . .—•—• •—•—•—•'' •—•—•—•—•—•—•—• —•—•—•—•—•— I � EXP�SED FR rol'IN� � ' i �' I I ' � (BEAMS & �------- ---- - I � COLUMNS) SHALL � � � BE FIREPROOFED I � � � ' � 'WITH SPRAY i i 'I APPLIED FIRE ��... I ''� � ! 'PROOFING MATCHING � I I ' � 'EXISTING SFRM ON � � • I ' W14x22 ' � BLDG. � � W14x22 � I. �------ � I EXP�SED FRAMING . `� ' , iI , (BEAMS & , � i i . COLUMNS) SHALL � ' `V � ' BE FIREPROOFED ' � � � � I . X I I N WITH SPRAY • � ' � �� Y;;:: APPLIED FIRE � � • I PROOFING ' � I . MATCHING ' � i i � EXISTING SFRM ON I I I BLDG. W14x22 ' I i i W14x22 I. � .—.—.—.—.—.— . .—.—.—.—. .—.—. .—.—.—.—.—.—.—.—. .—. .—.—.—.—.—.—._ I i �� � . � � � �� �� i � . j �� � �� . N 'I' N I I I I � � � � � � � �� . ° 'I ° I' � � I � � i � i � � � I �� a i i I ii a � �� • W16x36 r_ � � W16x26 � : � _ I : ` 'I 1 ' ' ' y � ' ' ' �..1 , � . . • 'I 1 ' . . y I !LJ: L ; ,,,. 1 A1.1 M � I I I I � I I I I FIREPROOFING PLAN SCALE: 1 /4" = 1'-0" 0 2' 4' 8' PEDGOR DESIGN GROUP ��C Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Arch itect: `�����������y'�11tt��i t� I I i�Pflllll// ft���/J ✓�r ,�*�`�``� '�,��� ��� �����'�,��i �� ����T �,��,�� �'�S �:. � ''� � — �.. r ` � ��C1��3 � �+�? �� = STATE �}� f�+'�I A� �` ,��C�IF-llrl'�� � P!l1�lt![ i1V� � �� . � .0. .� � . � KEY PLA BLDG B SCALE: NTS e�-� ^�� ����� � �� --�.' . � • . f� —� .' . . � PLAN NORTH ��� � � � M � M � W � � N W ' }' `� � � O � � � � � �� � � � U � 4) � .� � � � � Z � .. � > — �� � � � ■ � � � � �� � � � U � � M � � � COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECTAND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUEDAS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINALAND UNPUBLISHED WORK OF THEARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFICAND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. OO COPYRIGHT 2012 JAMES R. STUTZMAN, AIA, Carmel, Indiana. STATE RELEASE SET 11.30.12 I JDR/DJS I JDR Revisions: STATE RELEASE SET - 11.30.12 Project Number: Sheet Title: Fireproofing & Equipment Support Plans Sheet Number: �