HomeMy WebLinkAboutplan-plans-21_M0.1 Mech Symbols & Abbrv.PDFABBREVIATIONS AND TERMS � DIAMETER, PHASE ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE ('F) 'F DEGREES FAHRENHEIT EW EMERGENCY EYEWASH OBD OPPOSED BLADE DAMPER A/C AIR CONDITIONING EWC ELECTRIC WATER COOLER OD OUTSIDE DIAMETER, OVERFLOW DRAIN ACC AIR COOLED CONDENSER EWT ENTERING WATER TEMPERATURE ('F) OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED ACCU AIR COOLED CONDENSING UNIT EXH EXHAUST OSD OPEN SITE DRAIN AD AREA DRAIN, ACCESS DOOR EXIST EXISTING OZ OUNCE AFF ABOVE FINISHED FLOOR F FURNACE P PUMP AFMS AIR FLOW MEASURING STATION F&T FLOAT AND THERMOSTATIC STEAM TRAP PBD PARALLEL BLADE DAMPER AGA AMERICAN GAS ASSOCIATION FCO FLOOR CLEANOUT PC PLUMBING CONTRACTOR AHU AIR HANDLING UNIT FCU FAN COIL UNIT PD PRESSURE DROP AL ACOUSTICALLY LINED, ALUMINUM Fp FLOOR DRAIN, FIRE DAMPER PE PNEUMATIC ELECTRIC AMB AMBIENT FDC FIRE DEPARTMENT CONNECTION PH PHASE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE FDTN FOUNDATION PIV POST INDICATOR VALVE AO ANALOG OUTPUT FE FIRE EXTINGUISHER PPM PARTS PER MILLION AP ACID PROOF, ACCESS PANEL FHC FIRE HOSE CABINET PRV PRESSURE REDUCING VALVE APD AIR PRESSURE DROP (IN. WC.) FLR FLOOR PSI POUNDS PER SQUARE INCH ARCH ARCHITECT FM FACTORY MUTUAL PSIA POUNDS PER SQUARE INCH ABSOLUTE ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE FOV FUEL OIL VENT PSIG POUNDS PER SQUARE INCH GAUGE ARV AIR RELIEF VALVE FPM FEET PER MINUTE PTAC PACKAGED TERMINAL AIR CONDITIONER AS AIR SEPARATOR FPVAV FAN POWERED VAV UNIT PVC POLYVINYL CHLORIDE ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING FS FLOOR SINK R REGISTER AND AIR CONDITIONING ENGINEERS FSC FIRE SUPPRESSION CONTRACTOR R12 REFRIGERANT (12, 22, ETC.) ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS FSD COMBINATION FIRE/SMOKE DAMPER RA RETURN AIR ASPE AMERICAN SOCIEfY OF PLUMBING ENGINEERS FT FOOT, FEET RADN RADIATION ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS FTG FOOTING RAT RETURN AIR TEMPERATURE ('F) ATM ATMOSPHERE FTR FINNED TUBE RADIATION RCP REINFORCED CONCRETE PIPE AUTO AUTOMATIC G NATURAL GAS RD ROOF DRAIN AVG AVERAGE GA GAGE OR GAUGE REV REVOLUTIONS AVS ACID VENT STACK GAL GALLON RF REfURN FAN AW ACID WASTE GC GENERAL CONTRACTOR RG REfURN GRILLE AWWA AMERICAN WATER WORKS ASSOCIATION GIV GRAVITY INTAKE VENTILATOR RH RELATIVE HUMIDITY, RODDING HOLE BD BUTTERFLY DAMPER GPD GALLONS PER DAY RM ROOM BDD BACKDRAFT DAMPER GPH GALLONS PER HOUR RP RADIANT PANEL BE BOTTOM ELEVATION GPM GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE BF BARRIER FREE GR GRILLE, GRAINS RPS REVOLUTIONS PER SECOND BFC BELOW FINISHED CEILING GRV GRAVITY RELIEF VENTILATOR RTU ROOF TOP UNIT BHP BRAKE HORSEPOWER GT GREASE TRAP RV RELIEF VALVE, ROOF VENT BLDG BUILDING HB HOSE BIBB SA SUPPLY AIR BOD BOTTOM OF DUCT HD HEAD (FT.) SAN SANITARY BOP BOTTOM OF PIPING Hg MERCURY SD SUPPLY DIFFUSER, SMOKE DAMPER BSMT BASEMENT HHWP HEATING HOT WATER PUMP SEER SEASONAL ENERGY EFFICIENCY RATIO BT BATHTUB HO HUB OUTLET SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR BTM BOTTOM HORIZ HORIZONTAL SG SUPPLY GRILLE BtuH BRITISH THERMAL UNIT PER HOUR HP HORSEPOWER, HEAT PUMP SH SHOWER CA COMPRESSED AIR HR HOUR(S) SK SINK CAV CONSTANT AIR VOLUME HRTU HEATING ONLY ROOFTOP UNIT SMACNA SHEET METAL AND AIR CONDITIONING CB CATCH BASIN HX HEAT EXCHANGER CONTRACTORS NATIONAL ASSOCIATION CCW COUNTERCLOCKWISE Hz HERTZ SP STATIC PRESSURE CD CONDENSATE DRAIN IB INVERTED BUCKET STEAM TRAP SPEC SPECIFICATION CO2 CARBON DIOXIDE ID INSIDE DIAMETER SQ SQUARE CF CEILING FAN IE INVERT ELEVATION SR SUPPLY REGISTER CFM CUBIC FEET PER MINUTE IN INCH, INCHES SRV SAFETY RELIEF VALVE CH CHILLER INT INTERIOR SS SERVICE SINK, STAINLESS STEEL CHWP CHILLED WATER PUMP INV INVERT STD STANDARD CI CAST IRON IPS INTERNATIONAL PIPE STANDARD SV STEAM VENT CMP CORRUGATED METAL PIPE IW INDIRECT WASTE TCC TEMPERATURE CONTROL CONTRACTOR CO CLEANOUT K KELVIN TCP TEMPERATURE CONTROL PANEL COMPR COMPRESSOR KEC KITCHEN EQUIPMENT CONTRACTOR TD TEMPERATURE DIFFERENCE COND CONDENSER kW KILOWATT TE TOP ELEVATION CONV CONVECTOR LAB LABORATORY TEMP TEMPERATURE CP CONDENSATE PUMP LAT LEAVING AIR TEMPERATURE ('F) TF TRANSFER FAN CPVC CHLORINATED POLYVINYL CHLORIDE LAV LAVATORY TG TRANSFER GRILLE CT COOLING TOWER LBS POUNDS TMV THERMOSTATIC MIXING VALVE CU CONDENSING UNIT LD LINEAR DIFFUSER TONS TONS OF REFRIGERATION CUH CABINET UNIT HEATER LP LIQUID PETROLEUM TP TRAP PRIMER CUV CLASSROOM UNIT VENTILATOR LTG LIGHTING TRANS TRANSITION CV CONTROL VALVE LWT LEAVING WATER TEMPERATURE ('F) TS TAMPER SWITCH CW CLOCKWISE MA MIXED AIR TSP TOTAL STATIC PRESSURE (IN. WC.) CWP CONDENSER WATER PUMP MAT MIXED AIR TEMPERATURE ('F) TXV THERMAL EXPANSION VALVE dB DECIBEL MAX MAXIMUM TYP TYPICAL DB DRY BULB MB MOP BASIN UCD UNDERCUT DOOR DF DRINKING FOUNTAIN MBH THOUSAND Btu PER HOUR UH UNIT HEATER DG DOOR GRILLE MC MECHANICAL CONTRACTOR UL UNDERWRITERS LABORATORIES DH DUCT HEATER MCA MINIMUM CIRCUIT AMPS UON UNLESS OTHERWISE NOTED DI DIGITAL INPUT MCC MOTOR CONTROL CENTER UR URINAL DIA DIAMETER MD MOTORIZED DAMPER US UP STREAM DIFF DIFFUSER MFR MANUFACTURER UV UNIT VENTILATOR DN DOWN MH MANHOLE V VOLTS, VENT DO DIGITAL OUTPUT MIN MINIMUM VAC VACUUM DS DOWNSPOUT, DOWN STREAM MISC MISCELLANEOUS VAV VARIABLE AIR VOLUME DW DISTILLED WATER MS MOP SINK VB VACUUM BREAKER DWG DRAWING MTD MOUNTED VD VOLUME DAMPER DWH DOMESTIC WATER HEATER MV MANUAL VENT VEL VELOCITY DWV DRAIN, WASTE & VENT N NITROGEN VERT VERTICAL DX DIRECT EXPANSION NA NOT APPLICABLE VF VENTILATION FAN EA EXHAUST AIR NC NOISE CRITERIA, NORMALLY CLOSED VFD VARIABLE FREQUENCY DRIVE EAT ENTERING AIR TEMPERATURE ('F) NEC NATIONAL ELECTRIC CODE VTR VENT THROUGH ROOF EC ELECTRICAL CONTRACTOR NFC NATIONAL FIRE CODE VUV VERTICAL UNIT VENTILATOR ECO EXTERIOR CLEANOUT NFPA NATIONAL FIRE PROTECTION ASSOCIATION W WASTE, WATT EDR EQUIVALENT DIRECT RADIATION NFWH NON-FREEZE WALL HYDRANT WC WATER COLUMN EER ENERGY EFFICIENCY RATIO NIC NOT IN CONTRACT WB WET BULB EF EXHAUST FAN NO NORMALLY OPEN, NITROUS OXIDE WC WATER CLOSEf EFF EFFICIENCY NOM NOMINAL WCO WALL CLEANOUT EG EXHAUST GRILLE NPW NON-POTABLE WATER WH WALL HYDRANT EL ELEVATION NTS NOT TO SCALE WPD WATER PRESSURE DROP (FT. HD.) EOM END OF MAIN DRIP 0 OXYGEN WSHP WATER SOURCE HEAT PUMP ES EMERGENCY SHOWER OA OUTSIDE AIR YD YARD DRAIN ESP EXTERNAL STATIC PRESSURE (IN. WG.) OAI OUTSIDE AIR INTAKE PIPING LINESYMBOLS HIGH PRESSURE STEAM (>61 PSIG) HPS STORM DRAIN ST MEDIUM PRESSURE STEAM (16-60 PSIG) MPS FOOTING/FOUNDATION DRAIN FD LOW PRESSURE STEAM (<15 PSIG) LPS SANITARY WASTE (W) HIGH PRESSURE CONDENSATE --- HPC --- SANITARY GREASE SG MEDIUM PRESSURE CONDENSATE --- MPC --- SANITARY FORCED MAIN FM LOW PRESSURE CONDENSATE --- LPC --- SANITARY VENT (V) BOILER BLOW DOWN BBD ACID WASTE AW BOILER FEED BF ACID VENT AV PUMPED CONDENSATE PC DRAIN D VACUUM PUMP DISCHARGE VPD INDIRECT WASTE IW HUMIDIFICATION H PUMP DISCHARGE PD MAKE UP WATER MU DOMESTIC COLD WATER (CW) - - - AIR RELIEF VENT ARV DOMESTIC HOT WATER SUPPLY (HW) -- -- -- HEAT RECLAIM PIPING HR DOMESTIC HOT WATER RETURN (HWR) --- --- --- HEATING WATER SUPPLY HHS 140'F HOT WATER 140'F HEATING WATER RETURN HHR 140'F HOT WATER RETURN 140'F REFRIGERANT DISCHARGE RD NON-POTABLE WATER - NPW - REFRIGERANT SUCTION RS DRINKING WATER SUPPLY DWS REFRIGERANT LIQUID RL DRINKING WATER RETURN DWR REFRIGERANT HOT GAS RHG SOFT WATER SW BRINE SUPPLY BS CHLORINATED WATER CL BRINE RETURN BR DISTILLED WATER DI CONDENSER WATER SUPPLY CS DEIONIZED WATER DE CONDENSER WATER RETURN CR FIRE SUPPRESSION F CHILLED WATER SUPPLY CWS NATURAL GAS (WC OR PSIG) G CHILLED WATER REfURN CWR GAS VENT GV DUAL TEMPERATURE SUPPLY DTS LIQUID PETROLEUM LP DUAL TEMPERATURE RETURN DTR MEDICAL COMPRESSED AIR (WC OR PSIG) MA HEAT PUMP WATER SUPPLY HPWS MEDICAL VACUUM MV HEAT PUMP WATER RETURN HPWR OXYGEN 0 GLYCOL HEATING SUPPLY GHS NITROGEN N GLYCOL HEATING RETURN GHR NITROUS OXIDE NO FUEL OIL SUPPLY FOS CARBON DIOXIDE CO2 FUEL OIL RETURN FOR WET VACUUM CLEANING WVC FUEL OIL VENT FOV DRY VACUUM CLEANING DVC CONDENSATE DRAIN CD COMPRESSED AIR (WC OR PSIG) A CONTROL WIRING • • • • TEMPERED WATER SUPPLY TWS TEMPERED WATER RETURN TWR PIPING IDENTITY SYMBOLS - ► � - FLOW DIRECTION ARROW, PITCH DIRECTION ARROW O O PIPE RISE � � - PIPE DROP 3 PIPE CAP - - S PIPE CONTINUES (REFERENCE ELSEWHERE) PIPE GUIDE X - PIPE ANCHOR � FLEXIBLE CONNECTOR - - o - - EXPANSION COMPENSATOR �L. : EXPANSION LOOP DI °I - CONCENTRIC, ECCENTRIC FITTINGS � I F � I I F UNION, FLANGED UNION - - DQ - - GATE VALVE I � f BALL VALVE DoQ - GLOBE VALVE I r BUTTERFLY VALVE - - I�JI - - PLUG VALVE 1\I CHECK VALVE ��� ,. PRESSURE REDUCING VALVE � � REDUCED PRESSURE BACKFLOW PREVENTER - D �� 4 - DOUBLE CHECK BACKFLOW PREVENTER ♦ ♦ O DOUBLE DETECTOR CHECK VALVE ASSEMBLY � " ANGLE VALVE � RELIEF VALVE � VALVE WITH OUTSIDE STEM & YOKE D�Q PNEUMATIC TWO-WAY CONTROL VALVE � - PNEUMATIC THREE-WAY CONTROL VALVE . . p�Q :. . .. ELECTRIC TWO-WAY CONTROL VALVE - - � . - - - ELECTRIC THREE-WAY CONTROL VALVE ,� , SOLENOID VALVE � FLOW SWITCH , Q , PRESSURE SWITCH � AQUASTAT I;I ORIFICE FLOW METER �� - VENTURI FLOW METER [�] TURBINE FLOW METER - - � - - CALIBRATED BALANCE VALVE � AUTOMATIC FLOW CONTROL VALVE I�I - STRAINER � STRAINER WITH CAPPED BLOWDOWN � MANUAL AIR VENT _ _ Q _ _ AUTOMATIC AIR VENT `� ,. VACUUM BREAKER , Y , TEMPERATURE/PRESSURE TAP Q THERMOMETER _ _ Q _ _ PRESSURE GAUGE �F&T - STEAM TRAP WITH DESIGNATION 0 o REFRIGERATION SIGHT GLASS - - O - - AIR FILTER/DRYER � REFRIGERATION THERMAL EXPANSION VALVE � - INLINE PUMP � DIFFERENTIAL PRESSURE TRANSMITTER � WHA-A WATER HAMMER ARRESTER WITH SCHEDULE TYPE �O FD P-TRAP AND RISER � 2�FD-1 FLOOR DRAIN WITH SIZE & SCHEDULE TYPE �� CO END OF PIPE CLEANOUT O FCO FLOOR CLEANOUT T W�� WALL CLEANOUT Q ECO EXTERIOR CLEANOUT OR RODDING HOLE �TMV-1 THERMOSTATIC MIXING VALVE WITH SCHEDULE TYPE --� HB-1 --� WH-1 HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE 101 . WATER METER I M�I. GAS METER O4"RD O 4"OFD ROOF DRAIN, OVERFLOW DRAIN WITH SIZE - - � - - POST INDICATOR VALVE � FIRE DEPARTMENT CONNECTION VALVE TAMPER SWITCH O UPRIGHT SPRINKLER HEAD - - O - - PENDANT SPRINKLER HEAD � DRY PENDANT SPRINKLER HEAD i!; CONCEALED SPRINKLER HEAD � SIDEWALL SPRINKLER HEAD HVAC I DENTITY SYM BOLS RECTANGULAR DUCTWORK ROUND SPIRAL DUCTWORK FLAT OVAL DUCTWORK 24/12 DESIGNATION IN INCHES, FIRST 24� DESIGNATION IN INCHES 24/12$ DESIGNATION IN INCHES, FIRST DIMENSION IS SIDE SHOWN DIMENSION IS SIDE SHOWN RECTANGULAR SUPPLY AIR, ROUND SPIRAL SUPPLY AIR, FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE OUTSIDE AIR DUCTWORK RISE OUTSIDE AIR DUCTWORK RISE RECTANGULAR SUPPLY AIR, ♦ ROUND SPIRAL SUPPLY AIR, ^ FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP �� OUTSIDE AIR DUCTWORK DROP v OUTSIDE AIR DUCTWORK DROP RECTANGULAR RETURN AIR, ROUND SPIRAL RETURN AIR, FLAT OVAL RETURN AIR, TRANSFER AIR DUCTWORK TRANSFER AIR DUCTWORK TRANSFER AIR DUCTWORK RISE RISE RISE RECTANGULAR RETURN AIR, ROUND SPIRAL RETURN AIR, FLAT OVAL RETURN AIR, TRANSFER AIR DUCTWORK �) TRANSFER AIR DUCTWORK � TRANSFER AIR DUCTWORK DROP DROP DROP RECTANGULAR EXHAUST AIR, ROUND SPIRAL EXHAUST AIR, FLAT OVAL EXHAUST AIR, RELIEF AIR DUCTWORK RISE RELIEF AIR DUCTWORK RISE RELIEF AIR DUCTWORK RISE RECTANGULAR EXHAUST AIR, ROUND SPIRAL EXHAUST AIR, � FLAT OVAL EXHAUST AIR, RELIEF AIR DUCTWORK DROP �� RELIEF AIR DUCTWORK DROP �� RELIEF AIR DUCTWORK DROP DUCTWORK CONSTRUCTED OF DUCTWORK RISE IN DIRECTION DUCTWORK DROP IN AL SS ALUMINUM, STAINLESS STEEL R� OF FLOW �� DIRECTION OF FLOW 20' 30' STANDARD DEGREE ANGLE RETURN AIR, EXHAUST AIR, � TRANSITION IN DIRECTION OF � SUPPLY AIR, OUTSIDE AIR IN ,�j TRANSFER AIR, RELIEF AIR IN FLOW DIRECTION OF FLOW DIRECTION OF FLOW ECCENTRIC DUCT TRANSITION CONCENTRIC DUCT TRANSITION RECTANGULAR TO ROUND, FLAT OVAL DUCT TRANSITION i VOLUME DAMPER ��� ACCESS DOOR DUCTWORK CAP AD M FD SD i MOTORIZED DAMPER WITH FIRE DAMPER WITH ACCESS SMOKE DAMPER WITH ACCESS � ACCESS DOOR DOOR DOOR BDD AMS FSD i BACK DRAFT DAMPER WITH i AIRFLOW MEASURING STATION FIRE AND SMOKE DAMPER � ACCESS DOOR � WITH ACCESS DOOR WITH ACCESS DOOR D i PRESSURE SENSOR WITH i TEMPERATURE SENSOR WITH i SMOKE DETECTOR WITH � ACCESS DOOR � ACCESS DOOR � ACCESS DOOR STATIC PRESSURE CHANGE IN FLEXIBLE DUCTWORK DUCTWORK LINING OR DOUBLE 3 INCHES CONNECTION ____ WALL DUCTWORK, DESIGNATION SHOWN IS FREE AREA 45' BEVELED FITTING FOR RADIUS DUCTWORK ELBOW RECTANGULAR TO (CENTERLINE RADIUS 1.5xW) sA SOUND ATTENUATOR RECTANGULAR DUCTWORK CONICAL FITTING FOR ROUND RADIUS DUCTWORK ELBOW OR FLAT OVAL TO � WITH TURNING VANES MITERED DUCTWORK ELBOW RECTANGULAR DUCTWORK CONICAL FITTING FOR ROUND WYE RADIUS DUCTWORK •' MITERED DUCTWORK ELBOW OR FLAT OVAL TO ROUND OR ELBOW WITH TURNING VANES FLAT OVAL DUCTWORK 45' LATERAL FITfING FOR ROUND 45' RADIUS DUCTWORK ELBOW TRANSFER AIR ELBOW WITH OR FLAT OVAL TO ROUND OR � DUCTWORK STUBS FOR FLAT OVAL DUCTWORK (CENTERLINE RADIUS 1.5xW) SOUND ATTENUATION SPIN-IN FITTING FOR ROUND CEILING PANEL SUPPLY AIR TO RECTANGULAR DUCTWORK, � DIFFUSER � ROUND SUPPLY AIR DIFFUSER LOW PRESSURE DUCTWORK FLEXIBLE DUCTWORK RECTANGULAR SUPPLY AIR RETURN AIR, EXHAUST AIR, CONNECTION TO DIFFUSER, � REGISTER � TRANSFER AIR REGISTER OR MAXIMUM SIX FEET GRILLE SIDEWALL SUPPLY AIR SIDEWALL RETURN AIR, � LINEAR SLOT SUPPLY AIR �� REGISTER OR GRILLE �� EXHAUST AIR, TRANSFER AIR DIFFUSER REGISTER OR GRILLE THERMOSTAT WITH ASSOCIATED DOOR GRILLE OR UNDERCUT 0 EQUIPMENT DESIGNATION O TEMPERATURE SENSOR � DOOR (TU-�2.34) (OPTIONAL) �y, HUMIDISTAT WITH ASSOCIATED � EQUIPMENT DESIGNATION CO3 CARBON DIOXIDE SENSOR CEILING DESTRATIFICATION FAN (TU-�2.34) (OPTIONAL) � TEMPERATURE CONTROL � VARIABLE FREQUENCY DRIVE ��� CENTRIFUGAL ROOF EXHAUST PAN EL FAN HYDRONIC REHEAT COIL WITH TERMINAL UNIT WITH �� ACCESS DOOR HYDRONIC REHEAT COIL INLINE FAN ELECTRIC REHEAT COIL WITH TERMINAL UNIT WITH ELECTRIC SERIES/PARALLEL FAN ACCESS DOOR REHEAT COIL POWERED TERMINAL UNIT � BASE MOUNTED PUMP UNIT VENTILATOR �� UNIT HEATER � HEAT EXCHANGER � AIR SEPARATOR o FINNED TUBE RADIATION REFERENCE SYM BOLS SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL ADDITIONAL INFORMATION. INFORMATION. SECTION LOCATION BEYOND AREA KEYNOTE INDICATORS IN DRAWING MODULE EXTENSION NUMERIC CHARACTER PLAN RELATES TO ITEM X POINT LEADER X X X X AREA LEADER SECTION LOCATION AT SUBSET SHEET LINE LEADER DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL DRAWING BLOCK TITLE REFERENCE DRAWING MODULE LOCATION FOR INFORMATION. INDICATOR: ADDITIONAL INFORMATION. LARGE SCALE VIEW LOCATION DETAIL LOCATION IN DRAWING MODULE LOCATION IN DRAWING MODULE DRAWING MODULE (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) � � ^ ` � DRAWING BLOCK TITLE N X X X I X , � SCALE: 1/8° = 1'-0" 0 4' 8' 16' ♦_♦ `� �' NUMERIC SCALE GRAPHIC SCALE NORTH ARROW LARGE SCALE VIEW LOCATION DETAIL LOCATION AT AT SUBSET SHEET SUBSET SHEET MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. INFORMATION. FLOOR PLAN OVERLAP BEYOND AREA REVISION INDICATOR � EXTENSION SEE XXX X � �� � REFER TO ADDITIONAL PLAN SHEET FOR CONTINUATION - - - REVISION CLOUD EQUIPMENT INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL DIFFUSER, GRILLE, REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. REGISTER INDICATOR: INFORMATION. TU-XL. � NUMERIC CHARACTER RELATES TO ITEM MULTIPLIER � (OPTIONAL) SCHEDULE TYPE ALPHANUMERIC CHARACTER RELATES TO BUILDING LEVEL (OPTIONAL) X X ALPHANUMERIC CHARACTER RELATES X TO ASSOCIATED AIR HANDLER (OPTIONAL) AIRFLOW (CUBIC FEET PER MINUTE) EQUIPMENT TYPE -� � � � A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS AS IF REPEATED HEREIN. B. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND DRAWINGS, AND BOTH ARE INTENDED TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. C. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E. THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING OR BEGINNING WORK ON THIS PROJECT. H. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. �• ANY DETAILS, SYSTEMS AND/OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. �• REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND TEMPLATE DRAWINGS FOR ALL MECHANICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATORS, SPRING ISOLATION, ETC., NOT SHOWN ON THE DRAWINGS. K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED MATERIALS INCLUDING ALL DIFFUSERS, GRILLES, AND REGISTERS. L. CONTRACTOR SHALL CLOSE ALL UNUSED OPENINGS IN EXISTING DUCTWORK. M. ALL DUCTWORK DESIGNATIONS REFER TO NET FREE AREA INSIDE THE DUCTWORK. N. VOLUME DAMPERS SHALL BE LOCATED AT BRANCH CONNECTION TO THE MAIN. 0. A MAXIMUM OF SIX FEEf OF FLEXIBLE DUCTWORK MAY BE USED AT ALL SUPPLY DIFFUSERS. BRANCH DUCTWORK TO DIFFUSER SHALL BE SAME SIZE AS DIFFUSER INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO DIFFUSER SCHEDULE FOR INLET SIZES. AVOID SHARP BENDS IN FLEXIBLE DUCTWORK WHICH MAY CAUSE EXCESSIVE NOISE. P. BRANCH DUCTWORK TO TERMINAL UNITS SHALL BE SAME SIZE AS TERMINAL UNIT INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO TERMINAL UNIT SCHEDULE FOR INLET SIZES. NOTATION DESIGNATORS GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES WITHIN THE DRAWING SET. GENERAL MECHANICAL NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN NOTES: THE DISCIPLINE. GENERAL SHEET NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON NOTES: WHICH THEY APPEAR. SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. SUBSET DESIGNATORS G-000 GENERAL A-000 ARCHITECTURAL F-000 FIRE SUPPRESSION P-000 PLUMBING M-000 MECHANICAL E-000 ELECTRICAL T-000 TELECOMMUNICATION SHEET TYPE DESIGNATORS M-000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) M-100 PLANS (DEMOLITION, SITE, FOUNDATION) M-200 PLANS (DUCTWORK, PLUMBING) M-300 PLANS (HYDRONIC PIPING) M-400 LARGE SCALE VIEWS (PLANS, SECTIONS) M-500 DETAILS M-600 SCHEDULES M-700 SHORT SPECIFICATIONS M-800 DIAGRAMS (CONTROLS, RISERS, ONE-LINES) M-900 3D REPRESENTATIONS (ISOMETRICS) LINETYPE DESIGNATORS THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS TO REMAIN. ______ INTERMEDIATE DASHED LINETYPE INDICATE EXISTING ITEMS TO BE REMOVED. INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE NEW — ITEMS. THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE. � INDICATES POINT OF NEW CONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. � INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. • 1 � � � � �I �I � � • � � �1 �I � • 1 • 1 • � � n �I i L AC UIS CONSULTING ENGINEERS 9229 DELEGATES ROW, SUITE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW.LACQUIS.COM Engineer: Y% /' 9.G. LL'!' ('9lFx. ��,m,�r s 3 r� a� » �4 #� f ;a� Y;,�> � }�s.��. By: KEY P BLDG B 9GNE NI5 �- - ..- � � � �. `� , `� , ;�; Project: �� ■ � M � � � r � � �--+ ._ � � � � � � �+ V � � � � � � i 0 � � Z � �� .� � � • \ � • � � � • � - � � � � U COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. m COPYRIGHT2006, 2007, 2008, 2009, 2070, 2071 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA STATE RELEASE SET Issue Date Drawn By Checked By 10/26/2012 SJO SJO Revisions: STATE RELEASE SET -11/30/2012 L'Acquis Project Number: 12226 Sheet Title: MECHANICAL SYMBOLS & ABBREVIATIONS Sheet Number: ■