HomeMy WebLinkAboutplan-plans-24_M5.1 Mech Details & Schedules.PDFSLIP JOINl ESCUTCHEON PLATE (TYPICAL) � �ONDENSATE DRAIN )OWN IN WALL TO DRAIN 1 1 /2" VENT WALL 2" WASTE � 1 � � � � 1 � � 1 � : ,., 24"MIN FOR EXHAUST, 36"MIN FOR OUTSIDE AIR INTAKE STAINLESS STEEL INSULATED CAP WITH 2" RIGID INSULATION CAULK WATERTIGHT � � ROOF STRUCTURE�� ROUTE ROOF MEMBRANE — UP TO UNDER COUNTER FLASHING AND � SECURE TO WOOD NAILER (TYP.) PROVIDE WOOD BLOCKING BELOW CURBS (TYPICAL) � COVER OPENING WITH 1/2"x1/2" MESH HARDWARE HOLE THRU ROOF TO � BE 1" LARGER THAN DUCT (BOTH DIRECTIONS) ROUTE ROOF MEMBRANE UP TO UNDER COUNTER FLASHING AND SECURE TO WOOD NAILER (TYP.) 16GA. GALV. DISCHARGE PLENUM �STORM COLLAR SECURED & CAULKED TO DUCT �CURB �LCURB CAP-SECURE TO DUCT & CAULK WATER TIGHT SEE PLAN FOR DUCT CONT. GOOSENECK DETAIL 2 . SCALE. NONE i i i ivn� i n nvv OR CONDUIT STORM COLLAR SECURED & CAULKED TO DUCT �SECURE WITH ROOFING NAILS 3" FROM CORNER AND MAX 6" O.C. MIN. 2 PER SIDE TYPICAL 6"� PVC SLEEVE FOR FUTURE REFRIGERANT PIPING INSULATED PIPE/DUCT CURB ASSEMBLY FILL VOIDS WITH BATT INSULATION ■ � , ■ � � � ' � . � DISCHARGE SHUTTER BY FAN M FG R UTILITY SET EF-1 W/ WEATHERPROOF COVER OVER MOTOR � FAN BASE SPRING ISOLATORS BY FAN MANUFACTURER, SECURE TO FAN BASE AND SUPPORT CURBS EQUIPMENT SUPPORT CURB (TYPICAL) - � SCRO DRAII� TRANSITION TO INLET DIAMETER AS REQUIRED FLEXIBLE CANVAS CONNECTION rGALVANIZED EXHAUST DUCTWORK, I CAULK WEATHERTIGHT AND PAINT MIN. 3 DUCT DIAMETERS � CAULKING BEAD COUNTERFLASH DUCTWORK CAULK SEAMS WEATHER- ROUTET� ROOF MEMBRANE UP TO UNDER COUNTER- FLASHING AND SECURE TO WOOD NAILER (TYP) ROOF CURB �REFER TO STRUCTURAL DWGS FOR SUPPO PROVIDE WOOD BLOCKING BELOW CURBS (TYPICAL) SCALE: NONE � RT ANGLES/CHANNELS FILL VOID WITH BATT INSULATION INSTALL CURBS PER NRCA AND MFGRS RECOMMENDATIONS � � � EXHAUST DUCT TERMINATION AT 45-DEGREE ANGLE. TERMINATE WITH BIRDSCREEN FAN COILUNITSCHEDULE FAN DATA MOTOR DATA ELECTRIC HEATING COIL DX COOLING COIL DATA FILTER DATA ELECTRICAL DATA DATA �N� SPECIFICATION MANUFACTURER WITH MARK LOCATION CONFIGURATION AIRFLOW MIN TOTAL SENS �`T �T W�BS� SECTION MODEL NUMBER NOTES (CFM) ESP DRIVE HP KW VOLTS PHASE MBH MBH DB WB DB Wg NPE MCA VOLTS PH � ) FCU-1 RINSE CYCLE 103 HORIZONTAL 800 .5 DIRECT 1/2 8 208 1 22.4 20.1 80 64 56 55 THROWAWAY 48.5 208 1 135 238200 BRYANT FV4CNF002 1,2,3 FCU-2 RINSE CYCLE 103 HORIZONTAL 1600 .5 DIRECT 3/4 - 208 1 46.6 40.8 82 65 58 56 THROWAWAY 8.5 208 1 207 238200 BRYANT FV4CN6006 1,2,3 FCU-3 RINSE CYCLE 103 HORIZONTAL 4000 .6 DIRECT 2.5 30 208 3 115.3 100.9 81 65 57 55 THROWAWAY 100.6 208 1 425 238200 BRYANT 524JE12H 1,2,3 NOTES: 1. R410A 2. HUMIDISTAT AND APR VALVE 3. 2-SPEED MOTOR CONTROLLER CONDENSING UNIT SCHEDULE DESIGN MIN. ELECTRICAL DATA LIQUID UNff CONNECT NOMINAL SUCTION SPECIFICATION MANUFACTURER WITH MARK LOCATION TO UNIT TONS AMB SEER/ LINE LINE SIZE WEIGHT SECTION MODEL NUMBER NOTES TEMP EER MCA VOLTS PH SIZE (LBS) CU-1 ROOF FCU-1 2 95 13 16.8 208 1 3/8" 5/8" 158 236201 BRYANT 2136NA024 1,2 CU-2 ROOF FCU-2 4 95 14 28.7 208 1 3/8" 7/8" 251 236201 BRYANT 213BNA048 1,2 CU-3 ROOF FCU-3 10 95 11 40.6 208 3 1/2" 1-1 /8" 740 236201 BRYANT 575JP 12B 1,2 NOTES: 1. R410A 2. LOW AMBIENT KIT EXHAUST FAN SCH EDU LE FAN DATA MOTOR DATA MARK SPECIFICATION MANUFACTURER WITH NOTES DESCRIPTION �PE CFM ESP RPM HP VOLTS PH SECTION MODEL NUMBER EF-1 UTILITY SET DIRECT 950 0.6 1725 1/2 208 1 233423 GREENHECK SFD-7.5-A 1,2,3,4,5 NOTES: 1 • SHAFT SEAL 2• DISCONNECT SWITCH 3• INCLUDE OUTDOOR SPRING-BASE ISOLATORS 4• BACKDRAFT DAMPER 5• SCROLL DRAIN ELECTRIC DUCT H EATER SCH EDU LE DUCT SIZE HEATING DATA ELECTRICAL DATA ACCESSORIES SPECIFICATION MARK CONFlGURATION MIN TEMP DISCONNECT INTEGRAL FLANGE MANUFACTURER WITH MODEL NUMBER NOTES W H MBH AMPS VOLTS PH SECTION KW RISE SWITCH THERMOSTAT MOUNT EDH-1 OPEN COIL 18" 16" 30 102 60' 85 208 3 YES NO YES 238201 QMARK OF-030-04-1-01-4-Y-N-N-16-18 1 NOTES: 1• INCLUDE 24V 1 PH CONTROL VOLTAGE AND SCR CONTROL WITH NON-FUSED INTERLOCKING DISCONNECT DIFFUSERS & GRILLES SCHEDULE DIMENSIONAL DATA THROW DATA PRESS. MAX NC ACCESSORIES MARK NOM CFM DISTANCE MOUNT DROP SOUND CEILING TAMPER- SPECIFICATION MANUFACTURER WITH NOTES FACE SIZE SLOT INFO DIRECTION C� NOM. BALANCE RADIATION PROOF SECTION MODEL NUMBER (IN. WC.) LEVEL DAMPER CFM DAMPER SCREWS SD1 300 24"x24" 3-CONE 360 10 SURFACE 0.075 <30 YES - - 233713 PRICE ASCD 1,2 SD2 500 24"x24" 3-CONE 360 10 SURFACE 0.093 <30 YES - - 233713 PRICE ASCD 1,2 SR1 100 8"x6" 3/4" C� 45' 2-WAY 8 DUCT 0.025 <30 YES - - 233713 PRICE 520D SR2 250 14"x6" 3/4" (� 45' 2-WAY 15 DUCT 0.006 <30 YES - - 233713 PRICE 520D RG1 - 24"x24" 1/2"x1/2"x1/2" - - SURFACE 0.021 <30 - - - 233713 PRICE 80 3 RG2 - 48"x24" 1/2"x 1/2"x 1/2" - - SURFACE 0.021 <30 - - - 233713 PRICE 80 3 ER1 - 24"X12" 1/2"x1/2"x1/2" - - SURFACE 0.021 <30 - - - 233713 PRICE 80 3 NOTES: 1. UNLESS OTHERWISE NOTED, DUCT RUNOUT TO DIFFUSER IS TO MATCH DIFFUSER INLET SIZE. 2. PROVIDE RADIAL OPPOSED BLADE DAMPER COMPLETE WITH DUCT RING, MODEL #VCR8 3. CONSTRUCT PLENUM BOX AT GRILLE INLET i L AC UIS CONSULTING ENGINEERS 9229 DELEGATES ROW, SUITE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW.LACQUIS.COM Engineer: Y% /' 9.G.^<iilL'!' ('9'l.'FZ'. �'*�Y�'Yi � � �• $: �. �v4 s s' ;a� kF> � � �s By: KEY P . . . � . .:� � �- - ..- � � � �. � � ;�; Project: �� ■ � M � � � r � � �--+ ._ � � � � � � �+ V � � � � L � i 0 � � Z � M � � �� .� 1 , \ � • � � � • � — � � � � U COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. m COPYRIGHT2006, 2007, 2008, 2009, 2070, 2071 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA STATE RELEASE SET Issue Date Drawn By Checked By 10/26/2012 SJO SJO Revisions: STATE RELEASE SET -11/30/2012 L'Acquis Project Number: 12226 Sheet Title: MECHANICAL D ETAI LS & SCHEDULES Sheet Number: ■