Loading...
HomeMy WebLinkAbout0114.97.4�4 I � ( m i LOWER CONC. PATIO 4 DROP WALL AS NECESSARY FOR N ! WALK OUT PATIO AS SHOWN t - -- 10' -0" I 64'4" 2'-4 9' FRENCH SLIDER 1----------------------------------------- - - - - -= - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---- _- _- _ - -__ -- - -- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — _ — — _ — — _ — — _ — I a I 4 I t Ln I I — J , HEADER IN WALL FOR L — — FUTURE OPENING �I �L� // I iy� > ► I I _ I FINISHED BASEMENT LAYOUT ALL WALLS IN FINISHED AREAS TO BE FINISHED W/ 1 GAS IN I I °� 3-1/2" FRAMNG INSULATION AS REQUIRED AND I I UNFINISHED STOR/ MEGH, p PAINTED DRYWALL W/ FLOORING TO BE CARPET = I I h? UNLESS OTHERWISE NOTED ON PLAN, v I I _ I I II I i ► ►I n' -8 i1/2' 31'4" 3'-6/2 - - - - - -- -- I/ , - -- - -- N - - - - - -- - `O z "► _ - - — _ - - - - - - - - - - - - - - - - - - - _- - - - - - - - - - - - - - - - - - - - - - - - - I DROP THIS AREA FOR HVAC r - co ' 1 r - , ► I , , i , ►' , O _ s --------------- - - - - -- I ,. L I I I I L - - - - - - - - - - - - - - - ------- - - - -,' , 1 i_ BATH I, T - -- � , 300 AMP SERVICE I ►' I O I � i I `` I i ABOVEINGARAGE , , I ►, i i I � I 1 '• �� � STORAGE UNDER STAIR I I I j '► i � 1 `�I 1 ►, I UNFINISHED T f I I I I ► I _ 4 I - -- - - -- l ! I I ► I 31.8" 3/2" i I SUMP PIT I FLOOR DRAIN I — — ► I , I ►I I I EJECTION PIT I ►, I FORM AND DROP FLOOR- _ _ _ -- ____ -- _ -� I I `_ -� C�ARACE SLAB 4" AS SHOWN THIS AREA I ° _ I I I N N r- - - - - - - - - - - - - - - - - - - - I I 4" CONC, SLAB OVER w- Z i 4" MIN. GRAVEL FILL I I w 1 I I Lu B I I I I I i I I I o ! I 1 I I I I I I I iq ! L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I ; I ----- - - - - -- - -- -- - - - - - - - - - - - - - - - - - -� 244 ° + Ib'•4" 6'4" 4' -0" 2' -2" 2' -0 " 4' -0" 2' -0" 2' -10" - -- - -- -- ------- - - - - -- 64' -4" FOUNDATION FINI5HED BASEMENT SCALE= 1/4" = V-011 cn NOTES: 1) ALL SOIL BASED ON 3000 P.61 2) ALL CONCRETE MIN. 3000 P,S.L 6 28 DAYS, 3) ALL FOOTINGS ARE 16" WIDE X 8" DEEP UNLESS NOTED OTHERWISE. 4) ALL WALLS ARE 8" THICK W/ BASEMENT WALL HT, AS NOTED AND GARAGE/ CRAWL/ SLAB WALLS 24" HIGH UNLESS NOTED OTHERWISE. 5) THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND JUDGE FOR THEMSELVES THE SUITABILITY OF THE PLANS IN RELATIONSHIP TO THE BUILDING SITE. 6) DRAWINGS SERVE AS A GUIDE TO THE CONSTRUCTION OF THE BUILDING, AND IN NO WAY DICTATE ANY OF THE LOCAL AND/ OR STATE BUILDING CODES, THEREFOR IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY AND CLARITY AND TO INSURE THAT ALL SUBS ARE CLEAR AS TO THE SCOPE OF THEIR WORK. CONTRACTOR WILL ACCEPT ALL RESPONSIBILITY FOR ERRORS OR OMISSIONS IN DESIGN OR DIMENSIONS. l) ALL STRUCTURAL MEMBERS AND BEAMS ARE BASED ON AN ASSUMED NEED, CONTRACTOR TO VERIFY ACTUAL NEEDS AND SIZES IF NOT SHOWN. 1 i x xl AA�',1 �J Ck 1 � �I Q .Q 1 0 (L z v 2 q Kf No K ;F m� X- wa�u-�� IL 11 0 `p � •9C. r Be S°0�� $ V w Lu O � (30D D U L Rnii cD C1 U LLI 0 CO � � U • V _1 a� X LL 0 1 c1() cYl cz 1 �V V Q) '0? L V y �o - } V W lawdo D DATE= -_ -- 02 -01-91 DRAWN BY= J. HOLLEY SCALE- AS 614010 REVISIONS; SHEET OF