Loading...
HomeMy WebLinkAbout0106.97.1I 0 N :AR ENT AY GARAGE 11-011 1 0 M 0 �^ I 55-811 — 241 -811 — -- — 171 -411 13411 20-4 1/2" 41-3 1/2" 61-111 5-2" 61 -1 I�UTLINE OF FOUNDATION _ FOR BRICK CHIMNEY AT _ N � FIREPLACE II10 I � � 0 1101 I -w- W8x18 5TL BM F PROVIDE MIN. I 8" POURED GONG WALL HVAC 5/A TO _ - I w N `^ III oc ° o �2 w �' W/ 4xI2 BRICK LEDGE CRAWL SPAGE i �°� o III c 81-0" POURED HT ON DRAWL III X III N 8'x 20" GONT. 5PREA0 1 5PAGE _ N 4% o FOOTING 5EE PETAIL5 PER SPEC y p POINT LOAD �' POINT LOAD _Y — °o CC o -{ }- PG T o I FROM A30VE FROM ABOVE PG ,; °• N a o - 24" H x 60" WIPE () KNEEWALL 3211 ABOVE N x w . oc o p ° DRAWL AGGES TAIR TREAD N05E III n -, o ts) o v w o > 2 -2x4 P05T 61 51 411 611 41 011 '� ::E � Q �o 2 -2x10 HD - - - - - - - - - —I 6 W TYP SAM POCKET- BLEEDER 1� 1 - - - - - ,�, - -- - - -+ aoccn x tY_ UJ � cu ED — _ 5 "PEEP vo°o o _ I 8"HIG - -_ - -- — I I I2 BLEEDER 11111 11 __ __ 1 1 © U I R -- - -2x WA "'f "G 2-2x10 HOR I LEAD WALL PAST �- �- I OVER OIG � M I W8x31 5TL BEAM ON � 3 - - - - - -- I FAU p --- - - - - -- - - - - - -- ? II 0'x30 xIZ'C IC 30p x 30" xl2" GONG PAD FTG 6 WALL ON 16" x 8" CONT. GONG THICKENED SLAB w CC �' I -2x12 5YP W/ N 2- 1/211 PLYWO FLITGHE5 51/2 13' -1111 I I I I 1 I I i I ' 201 -1111 I OUCH IN 3" PIPE FOR RADON EXHAUST 5A5EMENT II I 1 l y I I 1 1 i 1 ® W/ "T" BELOW SLAB 4" GONG. SLAB ON MIN _ 'r' PC _ XROU6H IN 1 1/2" PIPE o TO FLOOR DRAIN FOR 4" COMP. 5AW FILL ? o �O PG T FAU CONDENSATE o BLEEDER 1 1 #4 REBAR 124" O.G., 1' LONG BLEEDER fl 1 1 111 u- TO SPAN OVER -DIG I 201 -4 1/2" 351-3 1 /2" o UNEXGAVATED I I"MP Ilo2 Ilol 4 " GONG. SLAB W/ = — MIN. 4" GLEAN COMP. 5AND FILL LEAD WALL PA5T I I OVER DIG 5EE ELEVATION5 FOR FOUNDATION LAYOUT WAT I I R EN �E LOCATION IN TH15 AREA. NOTE - PROVIDE (2) 4 REBAR, TEN FT. LONG TO 5PAN UTILITY TRENCH 1 120 ---- - - - - -- 1 I 2' -611 161 -411 341 -411 21 -611 211 -4" FOUNDATION PLAN 1/411 _ 11 -011 NOTE= 50ME COLUMN DIMEN51ON5 ARE FROM CENTER OF COLUMN TO EXTERIOR FACE OF BA5EMENT WALL. NOTE: ERRORS AND OM1551ON5 WHICH MAY OCCUR IN THE CONTRACT DOCUMENT5 SHALL BE BROUCHT TO THE ATTENTION OF THE ARCHITECT, IN WRITING, AND WRITTEN IN5TRUGTION SHALL BE OBTAINED PRIOR TO PROCEEDING WITH CON5TRUCTION. THE CONTRACTOR SHALL BE HELD RE5PON51BLE FOR ANY ERROR5, D15GREPANCIE5 OR OM15510N5 FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR TO GON5TRUGTION AND /OR FABRICATION OF THE WORK. N 111 -SEWER - 5LEEVE -t- I 111 0 I 0 0 - VERIFY SUMP LOCATION W/ SUPERINTENDANT CCD 0 OR -•r F_ NOTE: FIELD VERIFY UTILITY LOCATIONS FOR 510E OF HOU5E W/ 5UPERINTENDANT G. M 16 HA WAN60( Architects / 601"13L 1365 Shenandoah Rochester Hills Michigan 48306 roo"'� sterBuil, Project INnIAN DIV1511 12220 North Mer Suite 1185 Carmel, Indiana d 5ubdvision / Plan IN IND5t Job No. WINP5� F�5eu aheet Title FOUNPATI PLAN AND OPT I ON5 a N Field. -verify all dimensions DO NOT SCALE DRA WINGS! 1.1 5HT of