HomeMy WebLinkAbout05040118-Site Plan (5o'R/w) Prepared Date:O~.07/05' By:. AMA Proposed Buyer(s): Jason '&:Charis Harper Community Rectrlc~s: Side Yard =N/A Redr Yard = 271 Aggregate = 10 (B.H.) R,H. of ~ndion~ Finished ~oor Bavarian Informotio~ Pod C-rode = 91I~ per p~on · -.-~,. I -,-.,- M~:'.h~e (S~nlteT w Storm) fine,lye Inlet [] C~rb wea (s~) ~.d se~fle. (Storm) .... Row L~e of swote Note: S~ltory ~w~ T~ of Casting ~flf~ati~ Upstre~ Monh~e, T~9~3.~ Downstream Manhole, TC-gH.80 Pad Grade + 0,7' = G~mg~ F~E (914.0) ~rage ~ + 1.5 = ,R~ti~l rTE (915;5) . Resldentlai FF[ - 9,0 = BaSement ~ (90~.5) Note: The garage finished fl~r elevation is 2.5' abov~ the curb et the dri~ per Dian. Sod Calculations; Drive = 925 SF:I: Public Walk = 295 ~+ PrN~te Walk = 52 SF+ H~roseeding =4,221 S¢+ Sod =384- SY~: , from Rear of residence. Sidewalk to be ploced f, from property line 4 from bo~ of curb pm' plan. Note: Per Compel zoning erdinonce 26.1,1: The resk~entinl ~tr~t limlte h~ht th tw~t~fl~ f~t (25'), h~e~ o dwsh~g may be hcreos~ In h~ht to ~i~fl~ f~t (~5') pro~ ~e side ~d r~ ~e h~d ~ edditinn~ ~e foot (1') f~ ~ch f~t (1') ~e structure exc~a the ~ tw~t~fl~ feet (25') h height. O _at # 258 Assumed North Sosle: 1" = 30' Note: Builder to ensure positive drainage away from structure(s). Note: Sump pump(s) to be placed by builder as needed. Note: This drawing is based on construction plans or record drawings, and is not based uoon o field survey. The Schneider Corporation doss not warren: the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be resorted to The Schneider Corporation Immediately; failing to ua so results in the contractors assumption of all ~lobJJlty. Note: '~e basement e~e'mtion, ooulcted hereon, has been determhe~ and based upon the pad groded and/or contours tokec from the oonotruotior plans for this subdivision. Unless stated, no information shoat fluctuating water tobies, soil conditions. ~r soil t)pes has becn provided or stated on said plans. It is recommended that the bosemect finished floor Devotions be at Ionst bra feet above the norm=t pool e~evgtion of any ed~ining bed[es of water, unless o study of facts reveals othemlee, If during the excavation process any Found water is witnessed, Re Schneider Corporat~ shonld be notified immediately, Re basement ~ewtlon should be raised two feet (2') above the ground water, and ~ddltionnl constructio~ techniques should be incorporated to alleviate future prouleme: Vb05.0031523 oo~, of G'oued/6troTh Water flow pottem f~ individoul FLOOD HAZARD STATEMENT CERTiFICA~ON so o3 /111~ - 15' DUaGE Flood Hazard Statement: The accuracy of any flood hazard data ShOWn on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazarc zone AE as said land plots by scale on flood insurance rate map #180081 0205 F for the City of Carmel. Indiana dated February 19, 2003,