HomeMy WebLinkAbout0300.97.100
I
20
0
I
0
I
I
i7
i
60
ELIMINATE TOP BLOCK COURSE
AT OVERHEAD DOOR ( -8 ") --�
ELIMINATE TOP BLOCK COURSE
AT OVERHEAD DOOR ( -8 ")
52' -8" 0/0 BRICK
20' -0" 32' -8"
18' -5" 16' -0,.
WOOD DECK
TO BE DESIGNED
AND BUILT BY BUILDER.
FOUNDATION VENT LOCATIONS
INSTALL QUANTITY AND
LOCATE PER CODE.
-- --- - - - - -- — -- --
- - - - - - - - - - - J
I
I
74 COURSES OF BLOCK
ON 8" x 16'w. x CONT.
CONCRETE FOOTING w/
HORIZ. REINFORCING.
I U
I 0 30"x30" CRAWL
ACCESS PANEL
CRAWL SPACE
18"
0 4 MIL. VAPOR BARRIER
x OVER 4" MINIMUM GRANULAR
N FILL
I
I 30 "x30" MECH.
ACCESS PANEL
I CONC. LINTEL POCKET
--------------- - - - - --
II ,
I I I TYPICAL OR POURED
1 CONC. PIERS - 32" MIN.
I I I I BELOW GRADE LINE.
II o o II
3 SEASON RM. ABOVE
I I ®Of 5/4 FLOORING
II 0 ABOVE GRADE II
II CN W II °
II a II I
II II Ln
II I,
Imo- ----------------- --11 -- ----------- 1--- - - - - --
I
I
I
i
I
I
I
I
I
(
II----------------- - - - --- i� I
1
CONC. LINTEL
I
20' -0" I
I I
PERIMETER DRAIN TO SUMP
i
I I I
I
SLOPE SLAB I
I TOWARD DOOR
I I
I I i
I I I
I I ROUGH IN BATH FIXTURES ONLY.
I I I
I I I
I I I
I I I
I
2o,-o" 8°
UNEXCAVATED AREA
4" CONCRETE SLAB OVER
4 MIL. VAPOR BARRIER &
4" MINIMUM GRANULAR FILL.
I
i
I
SLOPE SLAB i
TOWARD DOOR
I I
I I
I i
I I
I I
I I
I I
i I
------------------- - - - - -I
- - - - - - - - - - - - - - - - - - - - - - - - - - - u
21' -4"
OR FQ.�po
Rd Local,--des
„ r;�rlTY DEVEDPMENT
CITY C)F CAS
FOUNDATION PLAN
SCALE: 1 /4" =1 ' -0"
- - - - - - - - - - -T- - - - - - -
I
108" POURED CONCRETE
BSMT. WALLS w /REINFORCING I
PERIM. DRAINS, AND INSULATION.
I
I
i8..
Z
QWO
31' -4"
cv
i-
Z
�
i
W
Q
o
BASEMENT (UNFINISHED)
U)
}
Ll
Q
W
�
C
0
o
U
4" CONCRETE SLAB w/
U
W
I
a
( n
`' '
Q
W.W.F. RINFORCING AND
®
W
I
C
Z
4 MIL. VAPOR BARRIER
0
OVER 4" MINIMUM GRANULAR
X
I
FILL
`N
I
1
/
=- - - - - - -
- - - --
- - - - - - - - - - - - - -
-
- ---1
/
8x16 THICKENED
SLAB
DROP CEIL. 12"
i
FOR MECH. DUCT.
- - - --
T
2xE
- -- --
BRG. WALL
- - - -
--
I LAM. WOOD
BEAM
24"x24" CRAWL /MECH.
N
o
URNACE
ACCESS PANEL
7
32x32x12 CONC.
-
I
N
UTILITY
FOOTINGS
®
i
W
N
2x
BRG. WALL
cv
I I -- -
- - - --
—�
'I LAM. WOOD BEAM
—� I
0 3ER
S 6
)
6' -6
-J
3' -5 1 '
�
o
BASEMENT (UNFINISHED)
°
1
_
QD
I
®
1
I
°
SLOPE SLAB
°
X
I
c�
_
TOWARD SUMP
N
_
31' -4"
I
I
i Ii I
ANCHOR STRAPS OR
BOLTS PER CODE.
L---- -r - - -- -------- - - - - -- --------- - - - - -I
---- -7 - - -- �T - - - -1I CT - - - - --
0
N
4" WRAP AROUND
BRICK LEDGE
52' -8'
5' -0"
N.T.S.
8'-01.
31' -4"
4" BRICK LEDGE
UNEXCAVATED AREA
4" CONCRETE SLAB OVER
4 MIL. VAPOR BARRIER &
4" MINIMUM GRANULAR FILL.
12' -C "t
I
I
I
TYPICAL BEAM
POCKETS
BRICK VENEER
LEDGE — TYP.
I
V-
0
I
00
N
I
0
N
_I
FOUNDATION NOTES.
1. FHA APPROVED ANCHOR BOLTS AT 8" FROM CORNERS AND
6' -0" O.C. MAXIMUM.
2. SHADED AREAS INDICATE PLATE LINE.
3. STEP DOWN FOOTINGS WITH GRADE LINE.
4. BUILDER TO VERIFY SOIL BEARINGS w/ ENGINEER PRIOR TO CONSTR.
5. POURED 8" CONC. WALLS ARE 108" HIGH.
6. PROVIDE PERIMETER INSULATION AS REQUIRED BY CODE,
7. LOCATE SUMP PIT AND PUMP, PER SITE REQUIREMENTS.
V
ry
C
m
_J
m
Z
Z
QWO
uj
-I
i-
Z
�
(-D c
W
Q
o
W
W
Q
p
Z
O
w
cff
I
W
U
L
z
c
W
�
U)
}
Ll
Q
W
�
C
0
ZZ
df
U
U
�
U
W
—.J
W
a
( n
`' '
Q
Li
ry
v '
W
C
Z
—
I
DRAWING
m
�
Q
�
=
p
U
<
of
p
Q
M
DRAWING