HomeMy WebLinkAbout0363.97.15S U P E R V I S 0 R W R K H E E T
D
FOUNDATION CHECKLIST
FRAME PUNCH -OUT CH K LIST
BASEMENT
SLAB
1. GARAGE
GARAGE DOOR OPENING FRAMED TO CC E SIZE: Z' HT., S' OR 16' WIDE.
PROJECT INFORMATION
PROJECT INFORMATION
GARAGE ATTIC ACCESS FRAMED TO CORRECT SIZE AND LOCATION.
NAILERS AT ALL CORNERS OF GARAGE AND CEILING.
GARAGE STEP FRAMED AND KICK PLATE UNDER DOOR
HOUSE NAME / ELEV.
HOUSE NAME / ELEV.
BOW
-
P AN
STRAP ANCHOR NAILED CORRECTLY
SET NUMBER
SET NUMBER
2. HOUSE
CHECK FOR BOW STUDS '
PLAN / JOB NUMBER
PLAN / JOB NUMBER
CHECK FOR NAILERS
MARK DOOR SWING DIRECTION AND SIZE
STANDARD OR REVERSED
STANDARD OR REVERSED
CHECK FOR CASING ROOM (MIN. 2" ON EACH SIDE)
CHECK CENTERLINE OF KITCHEN WINDOW
ANY NON -STD. CHANGES?
ANY NON -STD. CHANGES?
CHECK BULKHEAD DIMENSIONS (2" LONGER AND 2" WIDER THAN CABINETS)
CHECK WALL SIZES IN RELATION TO CABINET SPACE
CHECK VANITY SIZES IN RELATION TO WALL SPACE
FRONT OR SIDE LOAD
FRONT OR SIDE LOAD
CHECK VANITY DEPTH TO DOOR OPENING (MIN. 241/2")
CHECK DOOR OPERATION AND INSTALLATION
STD., ENLARGED, OR FULL BSMT.
ALL SIDING OR BRICK FRONT
CHECK WINDOW OPER'A'TION AND INSTALLATION
CHECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION
(IN SET •) (OPT. 293) (OPT. 295)
(IN SET M) (OPT. 490)
-- PITCH RAIL WALL INSTALLED 1/2" BELOW STRINGER AND 11/2" SHORT
HALF -WALL 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS)
ALL SIDING OR BRICK FRONT
MASONRY
HALF -WALL AT STAIRS PAST STRINGER 1 1!2"
(IN SET 10) (OPT. 49m)
FIREPLACE OPT. PRE -FAB
TUB PLATFORM BUILT CORRECTLY ib 1/2" HT., 39" X 51" INSIDE
BSMT. WINDOW OPT. QTY■
NO STUDS 0 24" O.C. AT CERAMIC AREAS. (I6" O.C. MAX.)
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
TUB BLOCKS INSTALLED AT CERAMIC AREAS.
(MARK LOCATION(S) ON PRINT
BUILDING PERMIT NUMBER
HAILERS FOR FIBERGLASS CUBS INSTALLED
FRONT PORCH WALL HT. TO BE
MEASURE VINYL Af;a=-AB FOR SQUARE
ABOVE TOP OF FTN. WALL
CB PANELS HAVE BLOCKS ON ENDS
LOT ADDRESS
CHECK FOR LOAD - BEARING POINTS IN HOUSE AND PROPER LOAD TRANSFER
FLUSH W/ c31/4" let FLR t J.l.'s 2" ABOVE W/ it 1 /5" let FLR T.J.L's 6" ABOVE W/ 14" let FLR T.J.i.'s
STRAP ANCHORS SECURED IN HOUSE
MASONRY
CRAWL SPACE AND BASEMENT CLEANED OUT
FIREPLACE OPT. PRE -FAB
TOWNSHIP
STAIRWAY SHIMMED (MAX. 1/2" GAP EAC4 SIDE)
let AND 2nd FLOORS LINE UP IN STAIR WELL
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
— __._^_ NO GAPS ABOVE STAIRWAY DRAFTSTOP
BUILDING PERMIT NUMBER
STAIRWAY DROP CEILING DONE CORRECTLY (CHECK PRINTS)
FROM STAIR NOSING
_.� HANDRAIL BLOCKS INSTALLED 32"
SAFETY BOOTS AND RAILS INSTALLED 3 1/2" FROM STRINGER
LOT ADDRESS
CHECKLIST
SQUASH BLOCKS INSTALLED PER PLAN AND T.J.I. DETAIL SHEET
FLOOR SHEATHING NAILED PER SPEC.'S
TOWNSHIP
MARK OUT ALL HAUNCHES NOT USED
FALL PROTECTION INSTALLED AT STAIR WALL OPENINGS
MARK IN FRONT PORCH WALLS IF NOT ON PRINTS
EYEBOLT AND ANCHOR POINT IN PLACE
CHECKLIST
WATER SLEEVE LOCATION MARKED
_ ALL DRAFT STOP INSTALLED ON CHASE AND BAND JOISTS
ALL TYVECK STAPLED IN -PLACE EXTERIOR
SUMP PUMP LOCATION MARKED SEWER AND WATER SLEEV E
�._ HIGHLIGHT ALL THICKENED SLAB FOOTINGS
ALL HOLES PATCHED IN INSULATION BOARD
LOCATIONS MARKED (3'W/ 4" SEWER
SUMP PUMP SLEEVE LOCATION MARKED COUPLER, 5'W/ 1 1/2" SLEEVE)
HIGHLIGHT ALL PAD FOOTING LOCATIONS
ALL TRIM INSTALLED PER PRINT
MARK OUT ALL HAUNCHES NOT USED HIGHLIGHT ALL BEAM POCKETS
BEAM TAKEOFF SHEET COMPETE AND TUNED IN TO FOUNDATION SUPERVISOR
3 1/2" RIPS 1/2 SHEATHING INSTALLED ON CORNERS
MARK IN FRONT PORCH WALL HIGHLIGHT ALL PAD FTG. LOCATIONS
(TO BE COMPLTED EVEN IF NO BEAMS REQUIRED)
ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES
IF NOT ON PRINTS
ALL DOORS TAPED ABOVE
BEAM TAKE -OFF SHEET COMPETE AND TURNED IN
PRINT NUNCx ON NAIL IN GARAGE
TO FOUNDATION SUPERVISOR
(TO BE COMPLTED EVEN IF NO BEAMS REQUIRED)
PERIMETER AND PANELS GLUED
INTERIOR WALLS GLUED DOWN `
D O NOT R E M V E O BLUEPRINTS FROM J O B S I T E
INTERIOR AND EXTERIOR WALLS NAILED INTO TRUSSES BELOW
SET TUBS INTO ROOM AND WIPE -OUT
1. EXCAVATOR PLACE PRINT TUBE INSIDE OF EXCAVATION.
ATTIC ACCESS INSTALLED IN HOUSE PER PRINT, 12" SIDES
AND
o
ALL WINDOWS INSTALLED PER PRINT, ELEVATION STACK
2. WALL CONTRACTOR LEAVE ON TOP OF WALL.
JOIST HANGERS NAILED FRONT AND SIDES
SITE PICKED UP AND PUT N PILE EACH DAY
�
3. PLUMBING CONTRACTOR LEAVE ON TOP OF WALL.
2X4 AROUND TOP OF CHIMNEY, 1 V2" PAST CHIMNEY FLAT
ALL GIRDER TRUSSES NAILED PER ENGINEERING
u 4. CONCRETE CONTRACTOR LEAVE ON TOP OF WALL.
REVISED 3n1r11
AP