HomeMy WebLinkAbout05040068-Site Plan I/1 Ham.
raining 12,625 $.F.+, in
~ Camden Lane ( 50' R/W)
Date: 03/29/05: By. AMA
C.c ~emonity R~trictiens:
Yard = 3?in.
Aggregate = 6 B.H.
M/~ Homes
Finished Floor Bevatisn Information
Pad Grade = 9t.7,3 per plan
Pad bode + 02 = Ooraga FFE (917.5)
~eFFE + 0.5' = Resident al FFE (918.0)
R~FTE ~ 9:0':~= Baenmont FTE (909.0)
Note:
the Ponemont elevat on, depicted hereen, has
been determined and based upon the pad
Fades end/or contours taken f~orn the
construction plans for this subalvision. Unless
stated, no information about fluctuating water
tablds, s~ conditions, or sail t)pes ha~ been
provided or stated on said plans. It is
recommended that the basement finished floor
elevations be at least two feet (2') above the
normal pool elevatien of any adjoining bodies
of water, uldess a study of facts reveals
athemies. If during the excavation process any
ground water is witnessed, 'Gle Schneider
Corporation shaedd be notified immedidtely. 1he
b~a?ment elevation should be raised two feet
(2) above the ground water, and additional
construction techn~ues should be incorporated
to alleviate future problems.
Note:
Ibis drawing is based m~ construcUon plans or record drawings,
and is not based upon o f'~d sunmy. ~e Schneider Corporation
~.oenes not warrant the accuracy or sufficiency of this hformotion.
tractors should verify existing c~dit~s prior to any
construction. Any discr~ency found on this drawing should be
reported to lhe Sehneida- Corporatiou immediately, failin9 to do
so results in the contractors assumption of alt liability.
~ Proposed Orades
000.0 Existing Grades
.-----O000--"-" Contour ~'ede
· ---,,- · Approx. Laterel Location
I ''"'' Sanitary Sewer Lines
v -- Water Su~dce Lines
....... Sub-Surfoue Dra~n Lines
~ Monhale (Sanitary ~ Storm)
~ Beehive isis. t (Storm)
Iai Curb inlet (Si;arm)
D End Section (Stor~)
~ Fire N~ant
......... Flow Line of swale
- BulldOg Une I~L / ~SL)
....... Eucenent Line
Note: Sanitary Sewer
Top of Cestin9 Intormat ed
Menh~e, TC=~t6:5o
per record drawing
Sod Celoulations~
Seeding = 2,4,t5 SF+,
Sod =747 SY:t: , from
rear of home.
Assumed Norf~
Scare:
Note: Builder to
ensure positive
drainage away
from structure(s).
Note: The garage finished floor elevation
is 0.8' aba~e the curb at the dr~e, per
pron. FLOOD HAZARD STATEMENT
CERT1RCAllON
· 16.0'
31.7
Rood Hazard Statement: ~e accuracy of any flood hazard data shown a.
this plot plan is subjoct to map scale uncertainty and to any other
uncertainty in lucafien or elevation on the referenced flood inesrouce rate
map (RRM). None of the within described tend lies within that special flood
oza d zone A, as said land plots by scale an Commumty Map Panel ~
1800810001C of the flood insurance rate maps (RRM) for Hamttou County,
Indiana, Dated May 19, 1981.
X
NO'i/: THE WITHIN PLOT PLA~ WAS PREPARED AT THE CUEN~S
RE(~JEST ~ITHOUT BENEFIT OF A RECORD PLAT. THE CONTRACTOR
AND/OR BUILDER HAS BEEN CAU'RONED THAT THE DEPICTED UNES
SHOWN HEREON ARE SUBJECT TO CHARGE.