HomeMy WebLinkAbout0587.97.15I V R R K S H E E T �
S U P E R
f3 W
RYLAND
FOUNDATION CHECKLIST
FRAME PUNCH -OUT CHECK LIST
B S E E NT
S L A B
1. GARAGE
GARAGE DOOR OPENING FRAMED TO CORRECT 51ZE: 1' HT., 8 OR 16' WIDE.
PROJECT INFORMATION
PROJECT INFORMATION
GARAGE ATTIC ACCESS FRAMED TO CORRECT SIZE AND LOCATION.
NAILERS AT ALL CORNERS OF GARAGE AND CEILING.
GAR44s' STEP FRAMED AND KICK PLATE UNDER DOOR
HOUSE NAME / ELEV.
HOUSE NAME / ELEV.
- BOW STUDS
STRAP ANCHOR NAILED CORRECTLY
SET NUMBER
SET NUMBER
2. HOUSE
CHECK FOR BOW STUDS
PLAN / JOB NUMBER
PLAN / JOB NUMBER
CHECK FOR NAILERS
MARK DOOR SWING DIRECTION AND SIZE
STANDARD OR REVERSED
STANDARD OR REVERSED
CHECK FOR CA51NG ROOM (MIN. 2" ON EACH SIDE)
GHEGK CENTERLINE OF KITCHEN WINDOW
ANY NON -STD. CHANGES?
ANY NON -STD. CHANGES?
CHECK BULKHEAD DIMENSIONS (2" LONGER AND 2" WIDER THAN CABINETS)
CHECK WALL SIZES IN RELATION TO CABINET SPACE
CHECK VANITY SIZES IN RELATION TO WALL SPACE
FRONT OR SIDE LOAD
FRONT OR SIDE LOAD
CHECK VANITY DEPTH TO DOOR OPENING (MX 24 1/2 ")
_ CHECK DOOR OPERATION AND INSTALLATION
STD., ENLARGED, OR FULL BSMT.
ALL SIDING OR BRICK FRONT
C44ECK WINDOW OPERATION AND INSTALLATION
CHECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION
(IN SET ") (OFT. 293) ( OPT. 295)
(IN SET ") (OFT. 4 W )
PITCH RA11.. WALL INSTALLED i/2" BELOW STRINGER AND ! 1l1" SHORT
ALL SIDING OR BRICK FRONT
HALF -WALL 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS)
MASONRY
- HALF -WALL AT STAIRS PAST STRINGER ! !/2"
(M SET ") (OPT. 49m)
FIREPLACE OPT. PRE -FAB
- TUB PLATFORM BUILT CORRECTLY lf, 1/2" HT., 39" X 51" INSIDE
BSMT. WINDOW OPT. QTY.
NO STUDS • 24" O.G. AT CERAMIC AREAS. (16" O.G. MAX-)
NCTE iN5T�: BRICK - E:��sE ON MASONRY FIREPLACES
TUB BLOCKS INSTALLED AT CERAMIC AREAS.
(MARK LOC-ATION(S) ON PRINT
p
BUILDING PERMIT NUMBER
— NAILERS FOR FIBERCsLASS TUBS INSTALLED
FRONT PORCH WALL HT. TO BE
MEASURE VINYL AREAS FOR SQUARE
TOP OF FTN. WALL
CB PANELS HAVE BLOCKS ON ENDS
.ABOVE
"
LOT ADDRESS
CHECK FOR LOAD - BEARING POINTS IN HOUSE AND PROPER LOAD TRANSFER
„ "
FLUSH W/ 9 t/4 let FLR TJ.1.'e 2 ABOVE W/ 11 1/8 let FLR TJ.I, a 6 ABOVE W/ 14 let FLR. 7- 1.1.'6
STRAP ANCHORS SECURED IN HOUSE
MASONRY
CRAWL SPACE AND BASEMENT CLEANED OUT
FIREPLACE OPT. PRE -FAB
TOWNSHIP
STAIRWAY SHIMMED (MAX_ 1/2" GAP EACH SIDE)
let AND 2nd FLOORS LINE UP IN STAIR WELL
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
NO GAPS ABOVE STAIRWAY DRAFTSTOP
BUILDING PERMIT NUMBER
STAIRWAY DROP CEILINCs DONE CORRECTLY (CHECK PRINTS)
_ HANDRAIL BLOCKS INSTALLED 32" FROM STAIR NOSING
LOT ADDRESS
SAFE'' BOOTS AND RAILS INSTALLED 3 1l2" FROM STRINGER
AND TJ.I. SHEET
CHECKLIST
SQUASH 5LOCK5 INSTALLED PER PLAN DETAIL
FLOOR SHEATHING NAILED PER 5PEC.'a
TOWNSHIP
-- 'Y - MARK OUT ALL -4jNCHES NOT USED
FALL PROTECTION INSTALLED AT STAIR WALL OPENINCs5
`.4_%RK N PRONT PORG1 -+ WALLS IF NOT ON FPRtN75
EYEBOLT AND ANCHOR POINT M PLACE y
CHECKLIST
-- _- ..J_ -_- WATER SLEEVE LOC 47, iON "4RKE^'
ALL DRAFT STOP INSTALLED ON CHASE AND BAND JOISTS
ALL TYVECK STAPLED fN -PLACE EXTERIOR
SUMP PUMP LOCATION MARKED SEWER AND WATER SLEEVE
- - -- 4-1i- TN'GKENED SL AL FOOTINGS
ALL HOLES PATCHED IN INSULATION BOARD -
LOCATIONS MARKED (3'W/ 4" SEWER
SUMP PUMP SLEEVE LOCATION MARKED COUPLER, 5'W/ I ]a" SLEEVE:
--- - - - - -- HiG► -L ;GNT ALL PAD FOOTING LOCATICNS
ALL TRIM INSTALLED PER PRINT
MARK OUT ALL HAUNCHES NOT USED HIGHLIGHT ALL BEAM POCKETS
SEMI -, TAKE -OFF SHEET GOMPLTE ::ND TUF NEC IN
_ TO FOUNDATION 5uPERV15OR
3 I/2" RJPS 1/7 SHEATHING INSTALLED ON CORNERS ^
MARK IN FRONT PORCH WALL _ kICsHLIGHT ALL PAD FTG. LOCATIONS
(TO BE COMf'LTED EVEN IF NO BEAMS REQUIREC.
ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES
IF NOT ON PRINTS
ALL DOORS TAPED ABOVE
- -- BEAM TAKE -OFF SHEET COMPLTE AND TURNED M
PRINT HUNG ON NAIL IN GARAGE
TO FOUNDATION SUPERVISOR
(TO BE COMPLTED EVEN IF NO BEAMS REQUIRED)
_
_ PER!METER AND PANELS GLUED
INTERIOR WALLS GLUED DOWN
DO NOT REMOVE BLUEPRINTS FROM JOBSITE
INTERIOR AND EXTERIOR WALLS NAILED INTO TRUSSES BELOW
INTO AND
SET TUBS ROOM WIPE -OUT
1. EXCAVATOR PLACE PRINT TUBE INSIDE OF EXCAVATION.
ATTIC ACCESS INSTALLED IN HOUSE PER PRINT, 12" SIDES
ALL WINDOWS INSTALLED PER PRINT, ELEVATION AND STACK
Q
2. WALL CONTRACTOR LEAVE ON TOP OF WALL.
HAWSERS, NAILED FRONT AND SIDES
JOIST HA
SITE PICKED JP AND PUT IN RILE EACH DAY
3. PLUMBING CONTRACTOR LEAVE ON TOP OF WALL.
2X4 AROUND TOP OF CHIMNEY; 1 1/2" PAST CHIMNEY FLAT
ALL GIRDER TRU65E5 NAILED PER ENGINEERING
4. CONCRETE CONTRACTOR LEAVE ON TOP OF WALL.
REvtg; =C 3�2�I91
t r
is
i
i
f