FOUNDATION CHECKLIST
FRAME PUNCH -OUT CHECK LIST
SLAB
,. aARAaE
BASEMENT
GARAGE DOOR OPENING FRAMED TO CORRECT SIZE: 1' NT, B' OR Ib' WIDE. •`' `
\i
PROJECT INFORMATION
PROJECT INFORMATION
GAR.4CsE ATTIC ACCESS FRAMED TO CORRECT SIZE AND LOCATION.
HAILERS AT ALL CORNERS OF GARAGE AND CEILING.
GARAGE STEP FRAMED AND KICK PLATE UNDER DOOR
HOUSE NAME / ELEV.
HOUSE NAME / ELEV.
BOW STUDS
STRAP ANC44M NAILED CORRECTLY
SET NUMBER
SET NUMBER
s. HOUSE
PLAN / JOB NUMBER
PLAN /JOB NUMBER
CHECK FOR Bow STUDS
CHECK FOR NAILERS
MARK DOOR SWING DIRECTION AND SIZE
STANDARD OR REVERSED
STANDARD OR REVERSED
NECK FOR CASING ROOM (MIN. 2" ON !EACH SJDE)
CHECK CENTERLINE OF KITCHEN WINDOW
i
ANY NON -STD. CHANGES?
ANY NON -STD. CHANGES?
CHECK BULKHEAD DIMENSIONS (2« LONGER AND 2" WIDER THAN CARNETS)
CHECK WALL SIZES N RELATION TO CABINET SPACE
CHECK VANITY SIZES IN RELATION TO WALL SPACE
FRONT OR SIDE LOAD
FRONT OR SIDE LOAD
CHECK VANITY DEPTH TO DOOR OPENING (MN. 241/2")
CHECK DOOR OPERATION AND INSTALLATION :.
STD., ENLARGED, OR FULL BSMT.
ALL SIDING OR BRICK FRONT
CHECK WINDOW OPERATION AND INSTALLATION
(IN SET •) )OPT. 293) )OPT. 295)
(IN SET •) )OPT. 49m)
CHECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION
PITCH RAIL WALL INSTALLED 1/2" BELOW STRINGER AND 1 1/2" SHORT
ALL SIDING OR BRICK FRONT
HALF -WALL 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS)
(IN SET •) )OPT. 49m)
MASONRY
HALF -WALL AT STAIRS PAST STRRJCsER i 1/2"
FIREPLACE OPT . PRE - F A R
TUB PLATFORM 13UILT CORRECTLY Ib t/2" HT., 39" X 5'1' INSIDE ,
BSMT. WINDOW OPT. QTY'
NO STUDS • 24" O.C. AT CERAMIC AREAS. ( I6' O.C. MAX-)
NOTE: INSTALL BRICK LEDGE ON MAROrIRY FIREPLACES
TUB BLOCKS INSTALLED AT CERAMIC AREAS.
(MARK LOCATION(S) ON PRINT
BUILDING PERMIT NUMBER
HAILERS FOR FIBERGLASS TUBS INSTALLED
FRONT PORCH WALL HT. TO BE
ME, �suRE VINYL ARE.48 FOR SQUARE
ABOVE TOP OF FTN. WALL
GB PANELS HAVE BLocKB °" ENDS .
LOT ADDRESS
CHECK FOR LOAD - BEARING POINTS N HOUSE AND PROPER LOAD TRANSiR
FLUSH wr 9 I/4. lot FLR TJ.1: • 2" ABOVE uu 11 �/8" i.t FLR TJJ: • b' ABOVE W/ 14" lot FLR TJ.I.'s
STRAP ANCHORS SECURED IN HOUSE
MASONRY
GRALLIL SPACE AND BASEMENT CLEANED OUT
FIREPLACE OPT. PRE -FAR
TOWNSHIP
STAIRWAY SHIMMED (MAX. V1" GAP EACH BIDE) `
let AND 2nd FLOORS LINE UP IN STAIR WELL
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
— _ NO GAPS ABOVE STAIRWAY DRAFTSTOP
BUILDING PERMIT NUMBER
STAIRWAY DROP CEILING DONE CORRECTLY (CHECK PRMtB) .
HANDRAIL BLOCKS INSTALLED 32" FROM STAIR N081NG
LOT ADDRESS
_— SAFETY BOOTS AND RAILS INSTALLED 3 1/2" FROM STRWiER ;<<
CHECKLIST
SQUASH BLOCKS INSTALLED PER PLAN AND T.;.1. DETAIL SHEET
—
FLOOR SHEATHING NAILED PER SPEC.'s w`
TOWNSHIP
MARK OUT ALL HAUNCHES NOT USED
FA�L PROTECTION INSTALLED AT STAIR WALL OPENINGS
4S
MARK IN FRONT PORCH WALLS IF NOT ON PRINTS
-- EYEBOLT AND ANCHOR POINT IN PLACE`
CHECKLIST
WATER SLEEVE LOCATION MARKED
ALL DRAFT STOP INSTALLED ON CHASE AND BAND Jo18T3`
HIGHLIGHT ALL THICKENED SLAB FOOTINGS
L TYVECK STAPLED IN -PLACE EXTERIOR
SUMP PUMP LOCATION MARKED SEWER AND WATER SLEEVE
LOCATIONS MARKED (3' W/ 4" SEWER
HIGHLIGHT ALL PAD FOOTING LOCATIONS
ALL HOLES PATCHED IN INSULATION BOARD
ALL TRIM INSTALLED PER PRINT:'
5UriP PUMP SLEEVE LOCATION MARKED COUPLER 5' W/ 1 1/2- SLEEVE)
31/2" RIPS 1/2 SHEATHING INSTALLED ON CORNERS ' #'
MARK OUT ALL HAUNCHES NOT USED HIGHLIGHT ALL BEAM POCKETS
ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES
MARK IN FRONT PORCH WALL HIGHLIGHT ALL PAD FTG. LOCATIONS
IF NOT ON PRINTS
ALL DOORS TAPED ABOVE
PRINT HUNG ON NAIL IN GARAGE
PERIMETER AND PANELS GLUED
DO NOT REMOVE BLUEPRINTS FROM JOBSITE
__- INTERIOR WALLS GLUEDDOUN
INTERIOR AND EXTERIOR WALLS NAILED INTO TRUSSER BELOW >Y
- - - -- SET TUBS INTO ROOM AND WIPE -OUT -
1. EXCAVATOR PLACE PRINT TUIRE INSIDE OF EXCAVATION.
- -
ATTIC ACCESS INSTALLED IN HOUSE PER PRINT, 12" RIDES
�,
Q 2. WALL CONTRACTOR LEAVE ON TOP OF WALL.
ALL WINDOWS INSTALLED PER PRINT, ELEVATION AND STACK d
! -- JOIST HANGERS NAILED FRONT AND 61DE5 x
a
G 3. PLUMBING CONTRACTOR LEAVE ON TOP OF WALL.
_ SITE PICKED UP AND PUT IN PILE EACH DAYr
"
2x4 AROUND TOP of CHIMNEY, 1 1/2 PAST CHIMNEY FLAT
,. 4. CONCRETE CONTRACTOR LEAVE ON TOP OF WALL.
– L GIRDER TkU95E9 NAILED PER ENGINEERING'
~;
QQ S 4 i
ut ti k