Loading...
HomeMy WebLinkAbout1199.02.1GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE LATEST EDITIONS OF THE INDIANA UNIFORM BUILDING CODE, THE NFPA CODE, THE NATIONAL ELECTRIC CODE, THE NATIONAL PLUMBING CODE AND ALL OTHER STATE AND LOCAL CODES HAVING JURISDICTION. 2. THE ADA FEDERAL LAW SHALL APPLY TO THIS PROJECT. IT IS THE INTENT OF THESE DRAWINGS THAT THIS SPACE CONFORMS TO THE ADA ACCESSIBILITY GUIDELINES AS APPLICABLE TO THIS PROJECT. 3. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS IN THE FIELD PRIOR TO ORDERING MATERIALS AND PREFABRICATING ITEMS. ANY DEVIATION BETWEEN FIELD MEASUREMENT AND DRAWINGS SHALL BE REPORTED TO THE ARCHITECT. 4. EACH SUBCONTRACTOR SHALL VISIT THE SITE, PRIOR TO BIDDING AND IS RESPONSIBLE FOR FULLY FAMILIARIZING THEMSELVES WITH THE EXISTING CONDITIONS AND THE ENTIRE SCOPE OF THE PROJECT AND SHALL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THAT OF THE OTHER SUBCONTRACTORS ON THE PROJECT. 5. EACH SUBCONTRACTOR SHALL OBTAIN AND PAY FOR ANY AND ALL PERMITS AND INSPECTIONS REQUIRED BY LAWS, ORDINANCES AND PUBLIC AUTHORITIES HAVING JURISDICTION UNLESS AGREED TO OTHERWISE BETWEEN THE GENERAL CONTRACTOR AND SUBCONTRACTOR. 6. EACH SUBCONTRACTOR SHALL FURNISH AND INSTALL MISCELLANEOUS FORMS, BLOCKING, HANGERS, SUPPORTS, FITTINGS, ETC. NECESSARY TO FULLY COMPLETE THE JOB PROPERLY 13UT ARE NOT NECESSARILY SHOWN ON THE DRAWINGS. 7. ALL WORK SHALL BE OF THE HIGHEST QUALITY IN ACCORDANCE WITH THE ACCEPTED PRACTICES OF THE TRADE BY SKILLED CRAFTSMEN. 8. CONTRACTOR SHALL PROVIDE ALL SHORING AND BRACING REQUIRED FOR SAFETY AND PROPER EXECUTION OF THE WORK. ALL SUCH ITEMS SHALL BE REMOVED WHEN THE WORK IS COMPLETED. 9. SUBCONTRACTORS SHALL DO THEIR OWN CLEANUP, MOVE MATERIALS THAT ARE IN THE WAY OF CONSTRUCTION, AND REPAIR AND REPLACE ANY DAMAGE THEY DO, ETC. DEBRIS WILL BE REMOVED FROM THE BUILDING ON A REGULAR BASIS AT A RATE OF AT LEAST ONCE A DAY. EACH CONTRACTOR SHALL DO ALL CLEANING OF FINISH SURFACES RELATIVE TO THEIR WORK PRIOR TO ACCEPTANCE OF THEIR WORK. EACH CONTRACTOR SHALL COMPLY WITH ALL SPECIAL CLEANING INSTRUCTIONS. 10. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL BE AS INDICATED ON DRAWINGS AND SHALL BE VERIFIED WITH THE ARCHITECT IN CASE OF DISCREPANCIES OR QUESTIONS. ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH UNLESS NOTED OTHERWISE. IF INSUFFICIENT INFORMATION EXIST, CONTACT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 11. ALL WORK SHALL COMPLY WITH OSHA AND ALL OTHER APPLICABLE ENVIRONMENTAL LAWS. 12. THE FURNITURE AND THE EQUIPMENT ARE FURNISHED AND INSTALLED BY THE OWNER. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PREPARE FOR AND SCHEDULE THIS WORK INCLUDING THE RECEIVING, STORING AND PROTECTING OF ANY EQUIPMENT AND MATERIALS. 13. THE BUILDING IS TO REMAIN OCCUPIED DURING CONSTRUCTION, AND THE CONTRACTOR WILL TAKE THOSE MEASURES NECESSARY TO INSURE THE SAFETY OF THE OWNER, THE EMPLOYEES AND THE CUSTOMERS. ALL WORK TO BE PERFORMED IN A MANNER AS NOT TO DISRUPT BUSINESS. SCHEDULE WORK WITH THE MANAGEMENT. CONTRACTORS TO COMPLY WITH THE RULES AND REGULATIONS OF THE MANAGEMENT WHILE CONDUCTING WORK AND MOVING MATERIALS AND PERSONNEL IN AND OUT OF THE BUILDING. WHILE ON SITE, THE ARCHITECT IS RESPONSIBLE FOR HIS /HER OWN SAFETY BUT HAS NO RESPONSIBILITY FOR THE SAFETY OF THE OTHER PERSONNEL OR SAFETY CONDITIONS AT THE SITE. 14. SUBCONTRACTORS SHALL PROVIDE ALL CUTTING AND PATCHING REQUIRED TO COMPLETE THE INSTALLATION OF THEIR WORK. EACH SUBCONTRACTOR SHALL COMPLY WITH THE FOLLOWING: A. ALL CUTTING OF HOLES REQUIRED FOR INSTALLATION WORK AND WHICH ARE TO BE DRILLED OR BORED SHALL BE DONE BY THE RESPECTIVE DIVISION CONTRACTOR WHOSE TRADE IS INVOLVED. B. ALL CUTTING AND REPLACEMENT OF LINES AND SYSTEMS INCLUDING PIPING, DUCTWORK, CONDUIT, WIRING, ETC. SHALL BE PERFORMED BY APPLICABLE CONTRACTOR. C. EACH CONTRACTOR SHALL FURNISH THE GENERAL TRADES CONTRACTOR WITH, AND BE RESPONSIBLE FOR, EXACT LOCATION AND SIZE OF ALL HOLES AND OPENINGS REQUIRED TO BE CUT OR NECESSARY FOR HIS WORK. UNLESS SPECIFICALLY CALLED FOR ON THE GENERAL CONTRACT DRAWINGS, THE COST OF FORMING THEM SHALL BE BORNE BY THE CONTRACTOR REQUIRING THEM. 15. CONTRACTOR TO VERIFY BEFORE THE START OF CONSTRUCTION THAT ALL SPECIFICATIONS AND DESCRIPTIONS OF THE ITEMS INDICATED AS BEING THOSE OF THE EXISTING DO INDEED MATCH THE EXISTING CONSTRUCTION. 16. THE SITE IS TO BE IN A SAFE AND SECURE CONDITION AT ALL TIMES. CONTRACTOR TO PROVIDE SECURITY PROTECTION DURING CONSTRUCTION PERIODS WITH GLAZING AND TEMPORARY BARRIERS AND WALLS. 17. PROVIDE SOLID NON - COMBUSTIBULE WOOD BLOCKING IN STUD WALLS AS REQUIRED TO SUPPORT WALL MOUNTED CABINETRY, COUNTERS AND ALL OTHER COMPONENTS. 18. ALL CONCEALED INSULATION SHALL BE CLASS II MINIMUM. 19. ALL FINISHES SHALL BE MINIMUM CLASS II. 20. DOORS INDICATED ON THE PLAN SHALL BE LOCATED A MINIMUM OF 4" Fift INTERIOR BUILDING REMODEL for CARMEL EAST BRANCH 99 EAST CARMEL DRIVE CARMEL, IN 46032 Designed By: 8z ASSOCIATES UnID ARCHITECTS I N C O R P 0 R A T E D Suite 360, Longworth Hall 700 W. Pete Rose Way Cincinnati, Oh 45203 TEL: (513) 455 -5005 FAX: (513) 455 -5008 E -MAIL: architex @fuse.net FROM ADJACENT WALLS UNLESS NOTED OR DIMENSIONED OTHERWISE, OR AS REQUIRED FOR HARDWARE INSTALLATION. 21. THE ARCHITECT SHALL NOT BE RESPONSIBLE THE MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES OF CONSTRUCTION SELECTED BY CONTRACTOR. 22. ALL DOORS SHALL HAVE LEVER TYPE HARDWARE AND PERMIT EGRESS AT ALL TIMES WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. 23. CONTRACTOR TO PROVIDE FIFTH THIRD STAFF AND PROPERTY MANAGER WITH A SCHEDULE ILLUSTRATING HOW THE PROJECT WILL BE PHASED AND COMPLETED WHILE KEEPING; THE FACILITY OPEN DURING BANKING CENTER REGULAR BUSINESS HOURS. lqrl" OF CAL /CLAM' TOWNSHIP guy, Services Building & Code Enforcement i 14-1 Pt Floor; Carmel, l ,46032 r .$:PermiM/Forms /Autk>�n� 1-0i CODE DATA DESCRIPTION OF PROJECT: REMODEL & EXPANSION OF EXISTING BANKING CENTER USE GROUP: SECTION 304.0 (B) BUSINESS CONSTRUCTION TYPE: TABLE 603 V -N HEIGHT AND AREA LIMITATIONS: TABLE 5B 2 STORY, 20', 8,000 S.F. EXISTING TENANT AREA 2,344 S.F. ADDITIONAL TENANT AREA l,l 12 S.F. TOATAL TENANT AREA 35456 S.F. FIRE RESISTIVE CONSTRUCTION TABLE 6A EXTERIOR WALLS 0 HR Z FIRE WALLS 2 HR m COLUMNS/BEARING WALLS 0 HR A ROOF /CEILING 0 HR ELEECTRICAL /LIGHTING PLAN FLOOR 0 HR ELECTRICAL POWER PLAN FIRE SUPPRESSION NON- SPRINKLED OCCUPANCY LOAD (BANK) TABLE 10 A 25 (1 /100 S.F.) NO. OF EXITS 3 PROVIDED /(I) REQUIRED MAX. LENGTH EXIT ACCESS TRAVEL TABLE 1004.2.5.2.1 (200') VICINITY MAP CARMEL DRIE CARMEL X M m 0 r. m 0 D r n DRIVE E 116th STREET INDEX OF DRAWINGS T -1 U1 I DEMOLITION PLAN a Z A -2 REFLECTED CEILING V) m A -4 S C `IEDULES/DETAILS F -1 F N ; SH PLAN F -2 Z M m E -100 A E -101 ELEECTRICAL /LIGHTING PLAN CARMEL DRIE CARMEL X M m 0 r. m 0 D r n DRIVE E 116th STREET INDEX OF DRAWINGS T -1 TITLE SHEET D -1 DEMOLITION PLAN A -1 FLOOR PLAN A -2 REFLECTED CEILING A -3 SECTIONS/ELEVATIONS A -4 S C `IEDULES/DETAILS F -1 F N ; SH PLAN F -2 F _U NITURE PLAN M -101 N4ECHANICAL PLAN E -100 ELECTRICAL DEMO PLAN E -101 ELEECTRICAL /LIGHTING PLAN E -102 ELECTRICAL POWER PLAN E -103 TELECOM PLAN E -201 ELECTRICAL DETAILS P -101 PLUMBING PLAN PROJECT DATA & ASSOCIATES ,Kluni P ARCHITECTS IN C 0 R P 0 R A T E D Longworth Hall Suite 360 700 W.Pete Rose Way ,Cincinnati, OH 45203 "�� e ' Tel: (513) 455 -5005 r t t N `Fax: (513) 455 -5008 u r. '''' E -Mail: Architex @fuse.net N w__1 S CIT- Y MO O N.T.S. MOHA WK HILLS GOLF CLUB MERCHANTS SQUARE MALL Project Name: FIFTH THIRD BANK CARMEL BANKMARI Address: 99 EAST CARMEL DRIVE CARMEL, OH 46032 2. BUILDING DESCRIPTION: INTERIOR BUILDING REMODEL TO AN EXISTING COMMERCIAL BUILDING 3. EXISTING BUILDING: REMODEL AREA 3,456 SQ. FT. KEY PLAN a a a a N.T.S. 0 0 � i'( G•l � L C: � O Q Uz � ao m U Z '� F- W wM L .� Q �� = w J LLJ Q •� U u. REVISION: DATE & DESCRIPTION Q 0 0 0 0 JOB NO: K02182 SCALE AS NOTED DATE: 7/29/2002 DRAWN BY: D.A.L. CHECKED BY: J.C.K. FILE NAME: 02182 —T 1 SHEET TITLE: TITLE SHEET T =1 SHEET NO: 1 OF: I I