Loading...
HomeMy WebLinkAbout1199.02.3FLOOR PLAN SCALE: 1/4"=I'-O" NORTH GENERAL NOTES 1. ALL DIMENSIONS ARE TO FACE OF METAL STUD OR MASONRY. 2. BRACE NEW WALLS TO EXISTING CONSTRUCTION. 3. PROVIDE SHOP DRAWINGS FOR ARCHITECTS REVIEW ON ALL CASEWORK PRIOR TO FABRICATION. 4. PROVIDE "J" MOULD TRIM AT TOP OF GYP. BD. WALLS NOT IN CONTACT WITH CEILING. 5. COORDINATE ALL CONSTRUCTION WITH OWNER'S NETWORKING VOICE AND DATA CONSULTANT. 6. PROVIDE NECESSARY BLOCKING IN WALL TO SUPPORT CASEWORK AND OTHER EQUIPMENT. SYMBOL SCHEDULE QKEYNOTE DESIGNATION loi ROOM /SPACE DESIGNATION OA WINDOW DESIGNATION 101 DOOR DESIGNATION REVISION DESIGNATION ELEVATION OR DATUM WALL LEGEND 1 COLUMN REFERENCE GRID EXISTING WALLS 3 5/8" METAL STUDS @ 16" O.C. W/ 5/8" GYPSUM BOARD W/ SOUND ATTENUATION INSULATION BETWEEN STUDS. FLOOR PLAN NOTES: 101 EQUIPMENT DESIGNATION • CASEWORK DESIGNATION DETAIL DESIGNATION REFERENCE DRAWING NUMBER 1. FACE OF NEW WALL TO OCCUR FLUSH WITH FACE OF EXISTING WALL. 2. RELOCATED KITCHENETTE. FIELD VERIFY SIZE. 3. FIVE (5) NEW 18" DEEP SHELVES SPACED EQUALLY FLOOR TO CEILING SEE DETAIL G /A -3 4. EXISTING REAR TELLER COUNTER TO REMAIN. 5. PROVIDE MIN. GYPSUM BOARD ENCLOSER FOR EXISTING STEEL COLUMN. 6. NEW 12" DEEP SHELF WITH ROD INSTALLED AT 68" A.F.F.. SECOND SHELF INSTALLED AT 81" A.F.F. 7. RELOCATED CHECKSTAND. 8. EXISTING TELLER COUNTER TO REMAIN. 9. NEW WALL CABINETS. SEE DETAIL E /A -3. 10. NEW 2' -0" DEEP PLASTIC LAMINATE COUNTER @ 32" A.F.F. SEE DETAIL WA -3. 11. EXISTING DRIVE -THRU WINDOW TO REMAIN. 12. EXISTING ATM/ NIGHT DEPOSIT TO REMAIN. 13. VINYL TRANSITION (CARPET TO CERAMIC & AT V.C.T. TO CARPET). 14. 48" H. FRP PANELS AT TWO MOP SITrK WALLS. 15. WALL MOUNTED FIRE EXTINGUISHER FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 16. RELOCATE JANITOR'S SINK, TO THIS LOCATION. 17. EXISTING CONCRETE ISLAND TO REMAIN. 18. INSTALL NEW WINDOW TO MATCH EXISTING STORFRONT. PATCH EXISTING EXTERIOR AS REQUIRED. PROVIDE HORIZONTAL MULLION TO MATCH THAT ON EXISTING BRICK SILL AND INSTALL SPANDRELL PANEL BELOW MULLION AND 1" CLEAR INSULATED GLASS ABOVE. 19. UNDERCUT DOORS TO COUPON ROOM 108 & 110 TO ALLOW FOR CENTRAL AIR RETURN. 20. RELOCATED COPIER BY OWNER. 21. NEW P -0" DEEP PLASTIC LAMINATE COUNTER @ 30" A.F.F. SEE DETAIL H/A -3, 22. BUILD NEW WALL IN LINE WITH EXISTING STOREFRONT MULLION. I U1 m P & ASSOCIATES ARCHITECTS I I NC 0 R P 0 R A T E D 1 Longworth Hall Suite 360 700 W.Pete Rose Way Cincinnati, OH 45203 Tel: (513) 455 -5005 Fax: (513) 455 -5008 E -Mail: Architex @fuse.net 0 I., 0 0 w z W 0 z Y z Q m �I r� REVISION: DATE & DESCRIPTION 0 A 0 0 A JOB NO: K02182 SCALE AS NOTED DATE: 7/29/2002 DRAWN BY: Q.A.L. CHECKED BY: FILE NAME: J.C.K. K02182 —A1 SHEET TITLE: FLOOR PLAN A -1 SHEET NO: 3 OF: 11 _ >o 0 z Q LUQ m ao m oz < W W V) M <X • � Q Q V W sLd ry Q •� U �I r� REVISION: DATE & DESCRIPTION 0 A 0 0 A JOB NO: K02182 SCALE AS NOTED DATE: 7/29/2002 DRAWN BY: Q.A.L. CHECKED BY: FILE NAME: J.C.K. K02182 —A1 SHEET TITLE: FLOOR PLAN A -1 SHEET NO: 3 OF: 11