HomeMy WebLinkAbout0089.99.3REELECTED CEILING PLAN N POWER SCALE: 1/4" = 1'-0" 1 SCALE: 1 /4 8c COMMUNICATIONS PLAN ELEC_"TRICAL LEGEND 01' 110 VOLT DUPLEX WALL RECEPTACLE 110 VOL- 4 —FLEX WALL RECEPTACLE Gn DUPLEX RECEPT, W/ GROUND FAULT INTERRUPTER I �I TELEPHONE WALL RECEPTACLE E EXISTING -E,� D DEDICATED LIGHT — FLUORESCENT REF L. CEILING PLAN LEGEND CCU 2 X 4 FLUORESCENT SINGLE POLE SWITCH LIGHT — RECESSED FAdd EMERGENCY OR NIGHT -E,� 3 —WAY SWITCH Z LIGHT — FLUORESCENT a —� 4' STRIP FIXTURE O THERMOSTAT z CEILING HUNG a VN AIR SUPPLY DIFFUSER 2 X 4 LAY —IN GRID nr-, -2 < SUSPENSION SYSTEM z RETURN AIR GRILLE ® CEILING —MTD. EXIT LIGHT w U ® EXHAUST FAN W/ LIGHT AIR SUPPLY SLOT DIFFUSER MECHANICAL NOTES 1. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING DUCTWORK, LOCATION OF SUPPLY AND RETURN AIR, AND THERMOSTAT LOCATION. 2. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING MECHANICAL SYSTEM AFTER INSTALLATION OF LIGHTING AND OR OTHER EQUIPMENT WHICH MAY AFFECT THE OPERATION OF THE UNIT. 3. FIRE SUPPRESION ENGINEER SHALL BE RESPONSIBLE FOR AND SHALL SUBMIT SPRINKLER PLANS WITH DETAILS AND WORKSHEETS FOR REVIEW AS PER SECTION 201(0)4, GAR(675) IAC, 4. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATION OF SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLS IF AND AS REQUIRED. 5. DJ DESIGN AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY MECHANICAL ENGINEERING. ELECTRICAL NOTES 1. ALL ELECTRICAL OUTLETS TO BE GROUNDED 2. G.C. TO PROVIDE 3/4" PLYWOOD PANEL FOR TELEPHONE EQUIP. WHERE INDICATED 3. DJ DESIGN AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY ELECTRICAL ENGINEERING. POWER AND COMMUNICATIONS LAYOUT IS TO SHOW OUTLET AND SWITCH LOCATIONS ONLY REFLECTED CEILING PLAN No ES: 1. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. v DAWN JONES DESIGN, INC. 9401 KERWOOD DRIVE INDIANAPOLIS, IN 46240 (317)571 -8177 FAX (317)571 -8280 TGS ARCHITECTS, INC. ARCHITECTURE PLANNING ENGINEERING 821 BROAD RIPPLE AVENUE INDIANAPOLIS, INDIANA 46220 PHONE 317) 255 -3475 FAX /MODEM (317Y 255-7359 %S tiaL�NC %,,, �c,�' GlsrEp No _ * 4186 * _ STATE OF _ 9 ItiDjA�P . r DATE: 1/5/99 SCALE 1 /411= 1 -0" DRAWN: DRJ All Ideas, designs and plans Indicated or represented by these drawings ore owned by, and the property of Do— Jones Design, Inc. Contractors si^oll verify and be responsible for all dinenslons on the ,Job sift. AU rights reserved, except for uses expressly permitted In wrltingg,informatlon shown or Included on . these d- awings are solely the property of Dam Jones Deslon, Ir PROJECT, COMMUNICATIONS/ POWER PLAN SHEETi A2 CCU Q w ry Z a w o � z ry a w nr-, -2 < ry a w U a) Q DATE: 1/5/99 SCALE 1 /411= 1 -0" DRAWN: DRJ All Ideas, designs and plans Indicated or represented by these drawings ore owned by, and the property of Do— Jones Design, Inc. Contractors si^oll verify and be responsible for all dinenslons on the ,Job sift. AU rights reserved, except for uses expressly permitted In wrltingg,informatlon shown or Included on . these d- awings are solely the property of Dam Jones Deslon, Ir PROJECT, COMMUNICATIONS/ POWER PLAN SHEETi A2