Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0240.97.2
u 70 14' -I0" 1 I 64 1/2" I /2'J 4'_911 9'-10" 51.111 34 1/2" SILL HT Z-2x10 HER 2 -2x8 HDR 48 4 -5L 6068 56D I 3060 __ __________________________J 2-2 12 M17 — — — 55'-0" 2 3.1 6'-1" 411 ' 21.911 2-ZxI2 HDR 2-2x12 147R r , .r. 4272 ` 2 -2x10 HER 4272 2x6 WALL • - - -- -------------------- 6" PREFAB FIREPLACE W/ HEARTH AND SURROUND PER LOCAL GORE 61-5" 13'-8'1 AZk¢ 31k4 3672 3672 3672 �Z+ s �__ X ____________ 4. 31 3/44 x 9f /2*MCBNf -F-? ARlN 7 POINT FOR BEAM ABOVE 2-2x12 WR N � LZNDRY 4 NOOK I , I �� i I N 1 19'0" GLG ° �--� ' �X ' 9'0" GLG FAM I L Y —_ JVINYL I------ - - - - -- - - - -- VINYL L_ - — 2-5TORY - I - -- 32" H KNEE WAL CARPET �_ TI, I5' II" I I 8' II I/2" 8'-10 I/2° 16'_111 13'-4 1 /2" 0110, of 51 _ o I FURNACE FLUE SOLID BLGK'G TO o L I V I N6 N BEARING BELOW 1� r^ I u u� STRAIGHT RU _ o,' 9 0 GLG o K IT6 N 2/8 9'0" GLG `? oc TO ROOF ABOVE — — — — — — — — — — — — — — — — — xl CARPET � o VINYL o o 1 > ZxI0 FLOOR JOISTS 12 0 G OVER NOTE= BONE J015T5 CONTINUOUS TO MIN. 811 PAST WINDOW ROUGH OPN6.4, N - -- - -- CLIP STAIR STRINGER / -- - - - - -� �I I +/ / BEARING I 1 n 1 11 101-311 NI I �� SEE DETAIL / 31.311 �� 41 -411 3'_2n 5'-10 1/211 WALL 2 I 3 -8 1 /2 31-211 4' 0" N 4' 0" 8'-6 1I � 3' STACK 2" H KNEEWALL FRAMING o B'0' H • 3/41 z 9 1/4 o - 21 I LVL O — - - -- UP 15 R 12 R 2-2x10 HDR � 2/8 pWDR N N o ell -----r------ _ 2/8 — —-_ 1 2/8 9'0" GLG `J - 5 5H 1 3A66 Co 2 3 4 5 6 8 N 4'-1 112" 3' 7" 5'_111 tfLE "' o _ - -__— 2-2xI2 HDR ART NIC 32 HI Z/6 SHELF - °—' \ 8 N rr]�L >k ROOF TRU55ES 24" OC. I t; I 16' x 7' OH GAR DOOR I FIRST FI -OOR PLAN 1/411 = 1141 201-811 3.1 W, N � � � I I � � ° FL. J5T.5 HANGERED a I 0 0 o 0 o TO BOND JST. - BOLT - o D IN IN6 131_111 N J 0 BOND J5T TO 6RIDER °' I m X TRU55 U51N6 5/8" AB'S I?5L 2/0 L IBRARY N 0 - CARPET 6" O.G. STAGGERE CARPET Ili -,u 1 — — _ — — -- — — — � IR BY MFR — - --- N I ,o - I 1 N ATTIC - GARAGE I I ACCESS I L — — — J >k ROOF TRU55ES 24" OC. I t; I 16' x 7' OH GAR DOOR I FIRST FI -OOR PLAN 1/411 = 1141 201-811 3.1 W, N REF. ELEVATIONS 2- 13/4" x 16" ML H PR W/ 8" x 4" x I /Z" LLV BOLTED W/ 3/4" THRU BOLTS 0 12" OG TO CARRY BRICK GABLE PER ELEVATION Fr I 11 �5 1 31 -711 II 0 _= FOYER O � II 2x6 BALLOON FRAME WALL DBL 2x6 12" OG 7'_911 I IR15 I u� 0 � � rn I 0 0 o � o D IN IN6 131_111 N J 0 m —° 9b'I GLG - I?5L 2/0 L IBRARY N 0 - CARPET CARPET Ili -,u REF. ELEVATIONS 2- 13/4" x 16" ML H PR W/ 8" x 4" x I /Z" LLV BOLTED W/ 3/4" THRU BOLTS 0 12" OG TO CARRY BRICK GABLE PER ELEVATION Fr I 11 �5 1 31 -711 II 0 _= FOYER O � II 2x6 BALLOON FRAME WALL DBL 2x6 12" OG 7'_911 I IR15 I � oc 0 "• I 0 o I IQ w 5" 131_111 N J 0 m = I?5L 2/0 L IBRARY 0 - I� 9'0" GLG CARPET p 15' -2 1/21' 2 3.1 REF ELEV.S NOTE . ALL OIMEN510N5 ARE FROM FACE OF STUD TO FACE OF 5TU0. ALL STUDS ARE 3 1/2' UNLF-55 NOTED. ALL OIMEN510N5 PRESENTED HERE ARE FRAME OIMEN510N5 ONLY - SEE SHT. 1.1 FOR FOUNDATION FOOTPRINT. REVIEW ALL WINDOW H12R HEIGHTS PER PLATE HT. AND VERIFY W/ ELEVATIONS AND CORNICE DETAILS U I 1'-10 1 12" I'_10 1/2" 11 „" NV ICJ I. ALL CA5E0 OPF-NIN65 GREATER THAN 48" WIDE HOLD HEADER T16HT TO PLATE 2. ALL 131-FOLO DOORS R.O.'S = 11/2" WIDER THAN DOORS HEADER HT. = 82" AFF 3. ALL.13I-PA55 DOORS R.O.'S = SAME A5 DOOR HEADER HT = 83" AFF 4. 2x BLOCKING UNDER ALL EXTERIOR 5WIN6 DOORS 5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L ID IN6 DOORS 6. TOWEL BARS (TB) OVER CABINETS AND TOILETS BLOCK IN6 TO BE 55" AFF TO CL 7. TOWEL BARS (TB) NOT OVER CABINETS AND TOILETS BLOCKING TO BE 3911 AFF TO CL 8. BLOCKIN6 FOR T155UE HOLDERS (TH) TO BE 24" AFF —ALL EXTERIOR HEADERS ARE 2-2x12 NOTE: FIELD CHECK ALL APPROPRIATE ANO CURRENT DETAILS FOR TH15 PROJECT PRIOR TO START OF CONSTRUCTION NOTE= ERRORS AND OMISSIONS WHICH MAY OCCUR IN THE CONTRACT 00GUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, IN WRITING, AND WRITTEN INSTRUCTION 5HALL Be OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION, THE CONTRACTOR SHALL Be WLQ RE5PON51BLE FOR ANY ERRORS, 015CREPANCIE5 OR O111115510N5 FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR TO CONSTRUCTION AND /OR FABRICATION OF THE WORK. G. M IGH-HAEL WAN60UR Architects / Consultants 1365 Shenandoah Rochester Hills Michigan 48306 (313) 656-1187 PtiLim Master Builder Project INP IAN D IV 15 ION 12220 North Meridan 5t. Suite #185 Carmel, Indiana 46C32 5ubdvision / Plan W I ND50R Job No. WIND50R �I N hl N N f• N Sheet Title FIRST FLOOR PLAN - GGl IVU. 2.1 Field verify all dimensions DO NOT SCALE DRAWINGS! © Copyright 1994 Pulte Home Corporation 4