Loading...
HomeMy WebLinkAbout1155.95.2NOTE: OFFSET FACE OF STUD 112' 3/4' RIGIt INSULATION FROM FACE, OF FOUND. HALL 4' CONCRETE SLAB 0 A O n d d v n d d n d n n 11 -112' MIN. GRANULAR FILL n P n ° ° n� > o lq v ° 0 0 0.- ° n °O °O °O n V v 0'. p o °° °° °° ° 00 ° 0° 112' EXPANSION MAT'L ° ° 0 00 00 ° n 00 °0 0 0 0 o ° V ° n V v V n d n d P nv vn v v nv L ° n v ► ° n ° � vv v ° n v CL v v n d n d v nv vn v v nv n° n v n v v v v n v 1' -4' FOUNDATION WALL of PORCH -BRICK TWO —STORY SLAB FOUNDATIONS NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL BRICK VENEER 3/4' RIGID INSULATION ANCHOR BOLTS AT 6' O.C. n d d n GRADE 17> 0 o O o °o 00 00 v n v v v vv v n v v n v Cd e v n d n v v nv v (11 n v n 140, n v v L v vv v n v v v A n d v n d n v 1' -4. -13 BATT INSULATION 2 MIL. VAPOR BARRIER ANCHOR BOLTS AT 6' O.C. 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' *L' BLOCK ON 8' C.M.U. x 16'x24* CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 2,000 P.S.F. R -13 BATT INSULATION W/ 2 MIL. VAPOR BARRIER 2X4 STUDS AT 16' 0. C. 3 1/4* BASE 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION M [ N. 12' U;fiAt�AR FILL TYPICAL FOUNDATION WALL: x 8' *L' BLOCK ON 8' C.M.U. x 16'x24* CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) r4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 2.000 P.S.F. FOUNDATION WALL.at HOUSE -BRICK TWO —STORY SLAB FOUNDATIONS 2X WOOD FINISH DOOR FRAME MATERIAL 62 DOOR TRIM BY 0. H. DOOR MANUFACTURER 4' GRANULAR FILL n d vL 112' EXPANSION MATERIAL v n d V d 0 0 det.estF49 2' OVERHEAD DOOR PROVIDE THICKENED SLAB AT FRONT 4' CONC. SLAB ON GRADE 6%8' GRANULAR FILL Yf*3% TYPICAL FOUNDATION at GARAGE BOOR ALL FOUNDATION TYPES d.t..tF37 det.estF64 NOTE: OFFSET FACE OF STUD 112' BRICK VENEER FROM FACE OF FOUND. HALL 2X4 STUDS AT 16" O.C. 3/4' RIGID INSULATION 112' DRYWALL R -13 BATT INSULATION W/ 2 MIL. VAPOR BARRIER 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION «m F 1N. GRADE ° o ° ANCHOR BOLTS AT 6' 0 C Z O CLJ 24- llll� O° o FINISH GRADE ° °o °o p° p, MIN. 12' GRANULAR FILL v v IQ v n v A P, 19 ° TYPICAL FOUNDATION WALL: n v v n ° v n x 8' "L' BLOCK ON 12' CAP BLOCK o ° ° n ° n x 16"x24' CONT. CONC. TRENCH 'cu v v n d FOOTING ON VIRGIN SOIL OR n° ° n ° ° n W/ (2) #4 BARS CONT. ON n ° n v n CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 1' -4' 2,000 P.S.F. FOUNDATION WALL at HOUSE - BRICK If 416s%, TWO —STORY SLAB FOUNDATIONS SIDING 3/4' RIGID INSULATION R -13 BATT INSULATION W/ 2 MIL. VAPOR BARRIER Z O CL 112* DRYWALL 2X4 STUDS AT 16' 0. C. 4' CONC. SLAB ON GRADE GRANULAR FILL O t CL NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL FIN. GRADE det.estF24 2X4 STUDS AT 16' 0. C. 112' DRYWALL 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION ANCHOR BOLTS AT 6' O.C. 12' GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' *L* BLOCK ON 8' C.M.U. x 16'x24' CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN BEARING CAPACITY OF i• -e' I I 2.000 P.S.F. Vn�nV��� w FOUNDATION WALL at HOUSE - SIDING TWO—STORY SLAB FOUNDATIONS aet.eStFie NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL 112' INSULATION SHEATHING u, SIDING W — ANCHOR BOLTS AT 6' 0. C. FIN. GRADE TYPICAL FOUNDATION WALL: ° o o x 8' CAP BLOCK ON 8' C.M.U. °� °� °� ° x 16' X24' CONT. CONC. TRENCH o� o� 00 FOOTING ON VIRGIN SOIL OR L n° d v n d ° ° v ° W/ (2) #4 BARS CONT. ON v a ° v ° CERTIFIED COMPACTED FILL W/ vv n vv ° n ° MIN. BEARING CAPACITY OF tl ° n ° ° d v n v v n 2.000 P.S.F. v n v n n v n v v vv vv v n ° FOUNDATION WALL at GARAGE - SIDING TWO —STORY SLAB FOUNDATIONS det.estF17 n° n v n v n v n v n v—e vv 0 °o °o Oo °o 00 00 00 00 c 1 112' 0 00 00 00 00 n ° ° n ov L v v n I d v n ° ° d v n v ° n v v v ° ° n v n ° v ° n ov n v v n v d v n d n d P, nv vn v n v n 1'-4- SLAB OVERHANG at PORCH TWO —STORY SLAB FOUNDATIONS SIDING 3/4' RIGID INSULATION 4' CONC. SLAB W /THICKENED EDGE 112' EXPANSION JOINT MATERIAL 11 112' GRANULAR FILL Cif W W C.J7 cl- W 0 O cu NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL o vv v n v v n v v n v n v o n o p v n v o po 0 o v n v 0 v o ° n v °o° 0 o n Nvll po 0.? o ° o ° 0 00 p nv po po n ° b, v n v v v n v v v v v v n v v n d n d v nv vn v v nv L ° n v v v v n v vv v ° n v ° vn d n d v n v v n v v n v 1' -4- 4' CONC. SLAB ON GRAN W/ THICKENED SLAB AT FIAT AND 2% DOWNSLOPE TOWARDS FRONT GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' CAP BLOCK x 16' X24' CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 2.000 P.S.F. det.estFl6 112' DRYWALL R -13 BATT INSULATION W/2 MIL. VAPOR BARRIER ANCHOR BOLTS AT 6' 0. C. 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION 12' GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' "L' BLOCK ON 8' C.M.U. x 16'x24" CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 2.0W P. S. F. FOUNDATION WALL at PORCH - SIDING TWO -STORY SLAB FOUNDATIONS 112* DRYWALL 3 1/4' BASE TRIM ° a v n ° a c Q ° Q 0° , 0f 0 o 00* v oo ° o° ° 0, v o° 0 00 0° Iq 00 0�- \ 1 WIDTH - SEE Sl F3 TYPICAL THICKENED TA of GAPING WALL det.estF14 1/2* DRYWALL 2X4 AT 16' 0. C. 4' CONC. THICKENED SLAB Wi 6 Nil. VAPOR BARRIER MIN. 12' GRANULAR FILL det.estF3 N � N « .r �+ N •� r N ...t U v Cb D ---. o Lu z US W S > > > "IL J ILI � � cx a W di 0 cm 0 z 0 tY 0 Q Vi o o �- M - Q Q W _ oz rn 1-- O c� z �/ � CL Q > > � // W W J Q Or_ det.estF24 2X4 STUDS AT 16' 0. C. 112' DRYWALL 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION ANCHOR BOLTS AT 6' O.C. 12' GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' *L* BLOCK ON 8' C.M.U. x 16'x24' CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN BEARING CAPACITY OF i• -e' I I 2.000 P.S.F. Vn�nV��� w FOUNDATION WALL at HOUSE - SIDING TWO—STORY SLAB FOUNDATIONS aet.eStFie NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL 112' INSULATION SHEATHING u, SIDING W — ANCHOR BOLTS AT 6' 0. C. FIN. GRADE TYPICAL FOUNDATION WALL: ° o o x 8' CAP BLOCK ON 8' C.M.U. °� °� °� ° x 16' X24' CONT. CONC. TRENCH o� o� 00 FOOTING ON VIRGIN SOIL OR L n° d v n d ° ° v ° W/ (2) #4 BARS CONT. ON v a ° v ° CERTIFIED COMPACTED FILL W/ vv n vv ° n ° MIN. BEARING CAPACITY OF tl ° n ° ° d v n v v n 2.000 P.S.F. v n v n n v n v v vv vv v n ° FOUNDATION WALL at GARAGE - SIDING TWO —STORY SLAB FOUNDATIONS det.estF17 n° n v n v n v n v n v—e vv 0 °o °o Oo °o 00 00 00 00 c 1 112' 0 00 00 00 00 n ° ° n ov L v v n I d v n ° ° d v n v ° n v v v ° ° n v n ° v ° n ov n v v n v d v n d n d P, nv vn v n v n 1'-4- SLAB OVERHANG at PORCH TWO —STORY SLAB FOUNDATIONS SIDING 3/4' RIGID INSULATION 4' CONC. SLAB W /THICKENED EDGE 112' EXPANSION JOINT MATERIAL 11 112' GRANULAR FILL Cif W W C.J7 cl- W 0 O cu NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL o vv v n v v n v v n v n v o n o p v n v o po 0 o v n v 0 v o ° n v °o° 0 o n Nvll po 0.? o ° o ° 0 00 p nv po po n ° b, v n v v v n v v v v v v n v v n d n d v nv vn v v nv L ° n v v v v n v vv v ° n v ° vn d n d v n v v n v v n v 1' -4- 4' CONC. SLAB ON GRAN W/ THICKENED SLAB AT FIAT AND 2% DOWNSLOPE TOWARDS FRONT GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' CAP BLOCK x 16' X24' CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 2.000 P.S.F. det.estFl6 112' DRYWALL R -13 BATT INSULATION W/2 MIL. VAPOR BARRIER ANCHOR BOLTS AT 6' 0. C. 4' CONC. SLAB ON GRADE W/ 6 MIL. VAPOR BARRIER OVER 2'X2' CONTINUOUS PERIMETER INSULATION 12' GRANULAR FILL TYPICAL FOUNDATION WALL: x 8' "L' BLOCK ON 8' C.M.U. x 16'x24" CONT. CONC. TRENCH FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF 2.0W P. S. F. FOUNDATION WALL at PORCH - SIDING TWO -STORY SLAB FOUNDATIONS 112* DRYWALL 3 1/4' BASE TRIM ° a v n ° a c Q ° Q 0° , 0f 0 o 00* v oo ° o° ° 0, v o° 0 00 0° Iq 00 0�- \ 1 WIDTH - SEE Sl F3 TYPICAL THICKENED TA of GAPING WALL det.estF14 1/2* DRYWALL 2X4 AT 16' 0. C. 4' CONC. THICKENED SLAB Wi 6 Nil. VAPOR BARRIER MIN. 12' GRANULAR FILL det.estF3 N � N « .r �+ N •� r N ...t U v Cb D ---. SD1 DATE: 8/3/95 o Lu z US W S > > > J � � cx a W di 0 cm 0 z 0 tY 0 Q Vi o o �- M - Q Q W _ oz rn 1-- O c� z � CL Q > > � W W W J Q Or_ SD1 DATE: 8/3/95 o Lu z W S to 0 J a W 0 cm 0 0 SD1 DATE: 8/3/95 o Lu W S to J W cm 0 0 tY Q o o �- M - Q Q _ oz rn 1-- O = ' � CL N � CO C3- 0 J Q z J SD1 DATE: 8/3/95