Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.1 CONSTRUCTION PLAN.pdf
Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Management: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RE / M A X Drawn By Checked ByPrint Date Revisions: 20 0 S O U T H R A N G E L I N E R O A D SU I T E 1 2 9 IN D I A N A D E S I G N C E N T E R 75CS5EXS75CS5EXS75CS5EXS75CS5EXS A1.1 CONSTRUCTION PLAN PEDCOR DESIGN GROUP, LLC 9/13/12 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2012, JAMES R. STUTZMAN, AIA, CARMEL. 10/1/12 CHECK SET MC LES 10/5/12 STATE RELEASE SET KEY PLAN SCALE: N.T.S. FIRST FLOOR APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 10. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 12. CENTER WALL ON COLUMN LINE. ALIGN FINISHED FACES. CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 10 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES AREA NOT IN CONTRACT. GENERAL CONSTRUCTION NOTES: DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE IS TO BE VERIFIED BY ARCHITECT. DO NOT SCALE DRAWINGS. 1. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES.2. ALL WALLS SHALL BE CHALKED OFF FOR ARCHITECT'S REVIEW OF NEW WALL CONSTRUCTION.3. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 4. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 5. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 6. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL.7. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 8. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. 9. W1 EXISTING PARTITION TO REMAIN NEW WALL PARTITION NEW STRUCTURAL PARTITION WALL LEGEND: NOTES: FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 11. FP17 NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. FP16 3-5/8" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" FROM FLOOR TO 7'-7 7/8" AFF. PROVIDE KNEE BRACING AT GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND W2 THE END OF THE WALL. INCLUDE DRYWALL CAP. SEE DOOR SCHEDULE FOR DOOR INFORMATION.13. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. 14. INSULATION FOR INTERIOR WALL APPLICATIONS SHALL BE FORMALDEHYDE-FREE, UNFACED, GLASS-FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 665, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THE STUD THICKNESS OF THE WALL INTO WHICH IT IS INSTALLED. 15. PROVIDE 1” HORIZONTAL MINI BLINDS AT STOREFRONT LOCATIONS. BLINDS TO BE LEVOLOR, RIVIERA 1", COLOR 892 LOW GLOSS BLACK. PROVIDE 3’-3” X 7’-0” DRYWALL WRAPPED OPENING. WATER HEATER TO BE LOCATED ABOVE THE ACCESSIBLE CEILING OF CONFERENCE ROOM 117. FP20 WALL FEATURE TO BE: SERENITY HEALTH — DEEP CREEK FALLS WALL FOUNTAIN — GLASS REFLECTIONS. FP6 PROVIDE STAINED WOOD BASE CABINETS WITH STAINLESS STEEL COUNTER, STAINLESS STEEL SINK AND FAUCET. SINK TO BE KOHLER K-3821. FAUCET TO BE SUPPLIED BY TENANT, INSTALLED BY CONTRACTOR. INCLUDE GARBAGE DISPOSAL AT SINK. SEE ELEVATION FOR DETAILS. FP7 PROVIDE GAS LINE W/VALVE FOR RANGE BELOW THE HOOD.FP10 PROVIDE STAINED WOOD BASE CABINETS WITH DRAWERS FOR FREE STANDING ISLAND WITH GRANITE COUNTER. SEE ELEVATION FOR DETAILS. FP11 PROVIDE BLOCKING IN THE WALL FOR WALL-MOUNTED TELEVISIONS.FP5 PROVIDE COAT ROD AND PLASTIC LAMINATE SHELF. SEE SECTION 2/A4.2 FOR DETAILS.FP4 PROVIDE 6’-0” X 3’-6” DRYWALL OPENING WITH PLASTIC LAMINATE COUNTER SURFACE AT 42” AFF. OPENING TO HAVE OVERHEAD DOOR — 652 SERIES — ROLLING COUNTER DOORS. SEE ELEVATION FOR DETAILS. FP13 PROVIDE EXHAUST HOOD. HOOD TO BE: BROAN ELITE — EW58 SERIES RANGE HOODS OR EQUAL. PROVIDE FIRE RATED PAINTED DRYWALL EXHAUST CHASE BETWEEN HOOD AND SOUTH EXTERIOR WALL. CHASE IS TO EXTEND UP TO THE UNDERSIDE OF THE STRUCTURE AND THEN EXTEND SOUTH. FP12 REFERENCE STRUCTURAL DRAWINGS FOR MEZZANINE CONSTRUCTION. MINIMUM HEAD CLEARANCE TO BE 7'-0". FP14 PROVIDE ¾”X4’X4’ FIRE RETARDANT PLYWOOD PHONE BOARD MOUNTED AT 3’-0” AFF TO BOTTOM. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL. FP18 PROVIDE WATER METER TO MONITOR WATER SUPPLY.FP19 PROVIDE PLASTIC LAMINATE BASE CABINETS WITH DRAWERS WITH PLASTIC LAMINATE COUNTER. SEE ELEVATION FOR DETAILS. FP15 3-5/8" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" 4- 7 / 8 " FROM FLOOR TO UNDERSIDE OF MEZZANINE ABOVE GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND OR MEZZANINE TO DECK ABOVE. PROVIDE 3-1/2" SOUND INSULATION INSIDE WALL. PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED COFFEE MAKER AND REFRIGERATOR ICE MAKER. FP8 PROVIDE WATER SUPPLY AND DRAIN FOR TENANT SUPPLIED DISH WASHER.FP9 W4 3-5/8" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" 4- 7 / 8 " FROM FLOOR TO DECK ABOVE. GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND W5 3-5/8" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" 4- 1 / 4 " FROM FLOOR TO DECK ABOVE. GYPSUM WALL BOARD ON ONE SIDE. WALLS TO EXTEND W6 4" CFS LOAD BEARING STUDS @ 16" OC WITH 5/8" FROM FLOOR TO MEZZANINE DECK ABOVE. PROVIDE GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND 4" SOUND INSULATION INSIDE WALL. PROVIDE WALL MOUNTED SHELVING AND BLOCKING IN THE WALL AS REQUIRED.FP21 CENTER WALL ON WINDOW MULLIONS. SEE DETAIL 1/A4.2 FOR DETAILS.FP22 ALL NEW WALLS TO BE TYPE W2 UNLESS NOTED OTHERWISE. W3 3-5/8" 20 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" 4- 7 / 8 " FROM FLOOR TO 6" ABOVE FINISHED CEILING. PROVIDE GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND 3-1/2" SOUND INSULATION INSIDE WALL. DUROCK IS TO BE USED AT ALL PORTIONS OF WALLS WITH TILE AND STONE FINISHES. SEE FINISH PLAN TO COORDINATE FINISH LOCATIONS. 16. NEW PARTIAL HEIGHT PARTITION 5- 1 / 4 " 4- 7 / 8 " PAINTED COLUMNS TO BE LEFT EXPOSED.FP23 PROVIDE PAINTED PITTCON REVEAL TO ALIGN WITH ADJACENT TOP OF WALL.FP24 DW F 4 A4.1 1 A4.5 3' - 0 " 2'-0" 9'-6 1/4"8'-0" 11 ' - 9 1 / 2 " 8' - 2 " 2' - 6 " 7' - 4 5 / 8 " 3' - 0 " 14'-3 3/4" 4'-0" 9'-7 1/2"12'-10 1/2" 3'-3 1/8" 8'-0"10'-1 7/8" 7'-5 1/4" 17 ' - 1 1 3 / 8 " 12 ' - 9 3 / 8 " 8' - 0 " 8' - 0 " 10 ' - 1 3 / 8 " 11 ' - 0 " 6' - 0 1 / 2 " 12'-3 7/8" 4 A4.3 3 A4.3 2 A4.3 1 A4.3 5 A4.3 6 A4.3 7 A4.3 8 A4.3 1 A4.1 2 A4.1 FP1 FP3 FP2 FP2 FP2 FP4 FP5 FP5 FP5FP5 FP5 FP5 FP5 FP13 FP14 FP5 FP16 FP16 FP16 FP16 FP16FP16 FP17 FP20 FP22 FP5 FP5 FP1 FP20 FP6 FP18 FP19 FP5 FP23FP23 FP23 FP24 1 1 2 A 1 1 3 117 1 1 1 1 1 0 101 108 107 1 0 6 1 0 0 A 109 1 0 5 SUITE 129 5,137 SQFT COLLECTION 115 BAR 116 CONFERENCE ROOM 117 OFFICE 108 OFFICE 107 CONFERENCE ROOM 106 CONFERENCE ROOM 105 OFFICE 109 OFFICE 111 OFFICE 112 DEVELOPMENT 113 KITCHEN 103 CAFE 102 OPEN OFFICE 104 RECEPTION 100 OFFICE 110 CL. 101 HALL 114 11 2 B W4 W4W6 W6 W3 W3 W6 W4 W4 W6 W6 W6 W6 CL. 101A DN UP DN UP L L.7L.6 L.9 MK.1K K.5 75CS5EXS 75CS5EXS .6 .5 1 3 2.9 2 11 ' - 2 1 / 8 " 10 ' - 2 1 / 4 " 9'-6 5/8"8'-0" 9' - 3 1 / 2 " 8' - 0 " 8' - 0 " 4'-6"8'-6" 2" 12'-11 5/8"8'-0" 8' - 0 " 13'-4 7/8"7'-11 3/4" 3' - 0 " 4' - 8 3 / 4 " 4'-8 7/8" 8'-0 3/4" 4 A4.3 3 A4.3 2 A4.3 1 A4.3 5 A4.3 6 A4.3 7 A4.3 8 A4.3 3 A4.1 FP16 FP16 FP2 FP2 FP22 FP14 FP15 FP17 FP5 FP16 1 2 1 125 122 123 124 1 3 0 1 2 9 1 2 6 131 1 2 7 1 2 8 OFFICE 126 OFFICE 127 OFFICE 128 OFFICE 129 OFFICE 130 OFFICE 124 OFFICE 122 OFFICE 121 OFFICE 125 OFFICE 131 OFFICE 123 HALL 120 HALL 119 COPY 118 W5W5 DN UP DN UP L L.7L.6 L.9 MK.1K K.5 75CS5EXS 75CS5EXS .6 .5 1 3 2.9 2 HARDWARE LS = L O C K S E T 7'-1"105 106 107 4'-2" 4'-2" 3'-0" 1 3/4" 1 3/4" 1 3/4" WD/ACR WD/ACR WOOD - SIZE CLOSET RO O M N A M E OP E N I N G NU M B E R 101 WID T H HE I G H T EL E V A T I O N MA T E R I A L TH I C K DOOR MA T E R I A L EL E V A T I O N FRAME SL SL REMARKS D O O R S C H E D U L E 108 109 110 OFFICE OFFICE D1 D4 D4 S = S T O P PS = P A S S A G E S E T SL = S L I D I N G D O O R LS,S 1. DOOR SCHEDULE NOTES: ALL NEW WOOD DOORS TO BE STAINED WS1. 2. 3. ALL HOLLOW METAL DOOR FRAMES TO MATCH BUILDING STANDARD. DOOR FRAMES TO BE PREPPED AND PAINTED SEMI-GLOSS P10. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4.HARDWARE TO BE: A. (LS, PS) SCHLAGE, AL-SERIES, SATURN STYLE, 626 FINISH LEVER HARDWARE. B. (SL) SLIDING DOORS TO BE ON HAFELE, FLATEC II, BARN DOOR HARDWARE W/8'-0" TRACK. INCLUDE SUGATSUNE DSI-2000-30-601 HANDLES ON BOTH SIDES OF DOORS. C. (S) STOPS TO BE HAGER -255S-US26 (WALL) AND 252F-US26 (FLOOR) AND 212-US26 (HINGE). CONFERENCE ROOM CONFERENCE ROOM OFFICE OFFICE 7'-1" 7'-0"D1 - -- HM 111 112A 113 3'-0"1 3/4"WOOD PS,S117 121 CONFERENCE ROOM D5 OFFICE OFFICE DEVELOPMENT OFFICE 7'-0"D5HM/GL 6'-8" 122 123 124 3'-0"1 3/4"WOOD HM LS,S 125 126 127 OFFICE OFFICE D3 OFFICE OFFICE OFFICE OFFICE D3 128 129 130 131 OFFICE OFFICE OFFICE OFFICE 112B OFFICE 7'-0"2'-6"1 3/4"WOOD HM PS,SD2D2 3'-0"1 3/4"WOOD D1 LS,S7'-0"D1HM 3'-0"1 3/4"WOOD D1 LS,S7'-0"D1HM 3'-0"1 3/4"WOOD D1 LS,S7'-0"D1HM 3'-0"1 3/4"WOOD D1 LS,S7'-0"D1HM 3'-0"1 3/4"WOOD D1 LS,S7'-0"D1HM EXISTING DOOR AND FRAME. 3'-0"1 3/4"WOOD D1 LS,S7'-0"D1HM 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 6'-8"3'-0"1 3/4"WOOD HM LS,SD3D3 PAINT TO MATCH WALL. COORDINATE KEYING LOCKSETS WITH OWNER.5.SLIDING DOOR. SLIDING DOOR. HINGE STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. WALL STOP. SLIDING DOOR INSERT TO BE AP1.6. CLOSET101A 7'-0"2'-6"1 3/4"WOOD HM PS,SD2D2 FLOOR STOP. 7' - 0 " 2" 2"2'-6"2" 7' - 0 " 2" 2"3'-0"2" 6' - 8 " 2" 2"3'-0"2"2"3'-0"2" 7' - 0 " 2" 7' - 0 " 4'-0" 7' - 1 " 4'-2" 8'-0" D1 D2 D4D3 D5 SCALE: 1/8" = 1'-0" 1 CONSTRUCTION PLAN - FIRST FLOOR A1.1 SCALE: 1/8" = 1'-0" 2 CONSTRUCTION PLAN - MEZZANINE A1.1 SCALE: 1/4" = 1'-0" 3 DOOR SCHEDULE ELEVATIONS A1.1 N N