Loading...
HomeMy WebLinkAboutA1.3 REFLECTED CEILING PLAN.pdfProject Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Management: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RE / M A X Drawn By Checked ByPrint Date Revisions: 20 0 S O U T H R A N G E L I N E R O A D SU I T E 1 2 9 IN D I A N A D E S I G N C E N T E R 75CS5EXS75CS5EXS75CS5EXS75CS5EXS A1.3 REFLECTED CEILING PLAN PEDCOR DESIGN GROUP, LLC 9/13/12 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2012, JAMES R. STUTZMAN, AIA, CARMEL. 10/1/12 CHECK SET MC LES 10/5/12 STATE RELEASE SET KEY PLAN SCALE: N.T.S. FIRST FLOOR CEILING HEIGHTS ARE NOTED ON THE PLAN. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES:CEILING PLAN NOTES: LOCATE NEW AND RELOCATED SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. LOCATE HEAT PUMPS ABOVE ACCESSABLE CEILING IN COLLECTION CONFERENCE ROOM. OPEN OFFICE CEILINGS ARE TO BE OPEN WITH ALL EXPOSED HVAC UNITS, AND CONDUIT TO BE PAINTED P5. DUCTWORK IS TO BE LEFT UNPAINTED. ALTERNATE 4: OPEN ARE CEILING OVER RECEPTION 100, CAFE 102, KITCHEN 103, OPEN OFFICE 1047, HALL 119, AND HALL 120 TO REMAIN BUILDING STANDARD WEB GRAY. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 CP2 EXISTING BULKHEAD TO REMAIN. PROVIDE DRYWALL CEILING WITH ACCENT WALLCOVERING W1. 6. 5. 4. 1. 2. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. T NEW TWO WAY SWITCH WITH TIMER. NEW TWO WAY SWITCH. GYPSUM BOARD CEILING. NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, DUNE, ANGLED TEGULAR W/ 9/16" PRELUDE XL GRID. REFLECTED CEILING LEGEND: 7. 8. 9. SYMBOL TYPE A LIGHT FIXTURE SCHEDULE RECESSED DOWNLIGHT MODEL CREE, 6" LED RECESSED DOWNLIGHT, LRC6-10L-DIMMABLE, 3500K W/RC6 HOUSING. WATTAGEDESCRIPTION MOUNTING HEIGHT NOTES B PENDANT LIGHT FIXTURE 18W D CREE LED TROFFER, CR14-40L-35K-S W/SMK-LE SURFACE MOUNT KIT. 12WE CREE, 6" LED RECESSED DOWNLIGHT, LR6C-10L-DIMMABLE, 3500K W/SC6 SURFACE MOUNTED HOUSING. F METALUMEN, ROUND PENDANT, R4A-4-N-J-4- SPECIAL FINISH-4-VOLTAGE W/T8 LAMPS. G TRANSLITE — BASIS CABLE MOUNT TRACK W/ RETRO 20 PENDANTS AND PHILLIPS ENDURA LAMPS. 50W H PHILIPS, FORECAST, AXO 4-LIGHT PENDANT, 190192836. J ARCHITECTURAL LIGHTING WORKS — COMMALITE, CML-16-HP7-LED-UNV-AL. CEILING 7'-0" AFF TO BOTTOM OF FIXTURE 40W 32W 7W CEILING @ MAIN LEVEL; 7'-5" @ MEZZ. C 84WPENDANT LIGHT FIXTURE SURFACE MOUNTED LIGHT FIXTURE SURFACE MOUNTED LIGHT FIXTURE PENDANT LIGHT FIXTURE TRACK LIGHT FIXTURE ACCENT PENDANT LINEAR WALL WASHER 50W 12W CEILING DIMMABLE DIMMABLE CP3 PROVIDE PAINTED DRYWALL BULKHEAD WITH RAISED ACOUSTICAL TILE CEILING AC1 AND CROWN MOLDING WM48. CP4 CEILINGS IN THE OFFICES AND CONFERENCE ROOMS ARE TO BE OPEN WITH PAINTED P5 DECK OR STRUCTURE OF THE MEZZANINE ABOVE WITH ALL EXPOSED CONDUIT TO ALSO BE PAINTED. DUCTWORK IS TO BE LEFT UNPAINTED. CP6 LIGHT FIXTURES ARE TO BE CONTROLLED ON OCCUPANCY SENSORS. CP7 TYPE C LIGHT FIXTURES AND LIGHT FIXTURES IN HALLWAY TO BE ON INDIVIDUAL ZONE OF THE TIMER SYSTEM. PROVIDE MANUAL OVERRIDE CONTROL TO TURN LIGHTS ON AFTER HOURS. CP5 PROVIDE 8” DEEP DRYWALL BULKHEAD WITH CUSTOM WALLCOVERING. BOTTOM OF BULKHEAD IS TO BE AT 7’-7 1/4” AFF. V2 LIGHTING GROUP, BRIO LX 1200 PENDANT, LBL-12-32. IMPACT ARCHITECTURAL LIGHTING, 12" IMAGO II PENDANT, P3012-242-SM-ADVANCE MARK 7 BALLAST W/(2) 42W TRIPLE TUBE 4P LAMPS. ALL LAMPS TO BE 3500K UNLESS NOTED OTHERWISE.10. DIMMABLE IN CONFERENCE RM. DIMMABLE 15'-0" AFF TO BOTTOM OF FIXTURE K STEP DIMMABLE 6'-6" AFF TO BOTTOM OF FIXTURE 7'-0" AFF TO BOTTOM OF FIXTURE 10'-0" AFF TO BOTTOM OF FIXTURE 15'-0" AFF TO BOTTOM OF FIXTURE EMERGENCY STROBES AND EMERGENCY LIGHT FIXTURES ARE TO BE WHITE UNLESS NOTED OTHERWISE. 11. COORDINATE LOCATIONS OF ACCESS PANELS IN DRYWALL CEILINGS WITH ARCHITECT.12. ALL LIGHT FIXTURES NOT CONTROLLED BY AN OCCUPANCY SENSOR ARE TO BE ON A TIMER.13. CP8 LIGHT FIXTURES IN COLLECTIONS TO BE ON INDIVIDUAL ZONE OF TIMER SYSTEM. PROVIDE MANUAL OVERRIDE CONTROL TO TURN LIGHTS ON AFTER HOURS. CP9 ACCENT LIGHT FIXTURES TO BE ON A SWITCH WITH TIMER ON MAIN LEVEL. CP10 TIMER SYSTEM TO BE LOCATED IN DEVELOPMENT ROOM. CP11 PROVIDE EXHAUST HOOD WITH DUCTWORK TO SOUTH WALL. HOOD TO BE BROAN ELITE, WE58 SERIES OR EQUAL. CP12 PROVIDE ALL-THREAD AND UNISTRUT AT 8'-0" FOR TENANT PROVIDED TV MOUNT. EXTEND ELECTRICAL OUT AND TV OUTLET TO UNISTRUT. VERIFY TV MOUNT SPECS PRIOR TO INSTALLATION. CP13 RAISE OR RELOCATE SPRINKLER LINES OVER MEZZANINE AREA TO RUN WITHIN THE DEPTH OF THE FLOOR JOIST. CP14 REMOVE AND CAP FRESH AIR DUCT OVER MEZZANINE AREA. CP15 RUN DUCTWORK WITHIN DEPTH OF FLOOR JOIST. SUPPLY ROOMS BELOW MEZZANINE WITH VERTICAL DUCTWORK WITHIN DEMISING WALL OR AT THESE PROPOSED LOCATIONS. MERCURY LIGHTING, EDGE LIT LED EXIT SIGNS, MER-ELXTE - RED LETTERS, CLEAR FACE, WHITE HOUSING. EMERGENCY EXIT SIGNS -- MERCURY LIGHTING, LED LOW PROFILE EMERGENCY LIGHT, MER-LEDR1 - WHITE.EMERGENCY LIGHTS -- NL NIGHTLIGHT LOCATION. D NEW TWO WAY SWITCH WITH DIMMER. NOT USED 10'-0"10'-0" 7'-8" 12'-0"11'-0" 7'-8" 7'-8" 7'-8"7'-8"7'-8"7'-8"7'-8" 7'-8" 7'-8" 3 A4.4 4 A4.4 CP1 CP5 CP2 CP3 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP6 CP6 CP6 CP6 CP6 CP6 CP6 CP6 CP6 CP7 CP8 CP6 CP7 AA A A A A B D F E E EE EE E E E EF AA H H H A A A A A D EE E E DD D D D D D D D D DD P3 W1 D D T P3 ACT1 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 D D D D D DN UP DN UP A A A A NL L L.7L.6 L.9 MK.1K K.5 75CS5EXS 75CS5EXS .6 .5 1 3 2.9 2 17'-0" 9'-5" 9'-5" 9'-5" 9'-5" 9'-5"9'-5"9'-5"9'-5"9'-5" 9'-5" 9'-5" 9'-5" 9 A4.4 CP7 CP4 CP6 CP13 CP4 CP6 CP4 CP6 CP4 CP6 CP4 CP6 CP4 CP6 CP4 CP6 CP4 CP6 CP4 CP6 CP4 CP6 CP12 CP12 CP12 CP12 CP12 CP11 CP9 CP15 CP15 CP15 CP15 CP15CP15 CP15 CP14 CP4 CP6 C J G D C C D D D D D D D D D DD C C C C C C C C C C C C C C C C C C P5 T T P5P5P5P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 DN UP DN UP NL NL L L.7L.6 L.9 MK.1K K.5 75CS5EXS 75CS5EXS .6 .5 1 3 2.9 2 SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN - FIRST FLOOR A1.3 SCALE: 1/8" = 1'-0" 2 REFLECTED CEILING PLAN - MEZZANINE A1.3 L.E.S M.C. N N