Loading...
HomeMy WebLinkAbout1126.95.1MECHANICAL EQUIPMENT SCHEDULE 1. SPLIT SYSTEM HEATING AND AIR CONDITIONING SYSTEMS CONSISTS OF AIR HANDLING UNIT WITH ELECTRIC HEAT AND AIR COOLED CONDENSING UNIT. CARRIER, TRANE OR EQUAL. PROVIDE WITH ACCESSORY THERMOSTAT HAVING HEAT -OFF -COOL AND FAN SUB BASE. PROVIDE LOCKING COVER COMPLETE WITH ALL OPERATING AND SAFETY CONTROLS. TWO STAGE HEATING WHERE INDICATED. SYSTEM 2000 CFM AND ABOVE SHALL BE PROVIDED WITH RETURN AIR SMOKESTAT FOR SYSTEM SHUTDOWN PER N.F.P.A. REFRIG PIPING SHALL BE SIZED AND INSTALLED PER MANUFACTURER RECOMMENDATIONS. INSTALL TRAPPED CONDENSATE DRAIN TO PLUMBING DRAINS. COORDINATE WITH PLUMBING CONTRACTOR. SYSTEM NO. 1: TRANE MODEL TWE090Al NOM. 7 -1/2 TONS COOL CAPACITY AT A.R.I. CONDITIONS 3000 CFM. 2 H.P. EVAP FAN MOTOR, 18 KW, 2 -STAGE ELECTRIC HEATER AT 480/3/ CONDITIONING UNIT: TRANE MODEL TTA090A AT 480/3/. 2. CORRIDOR 100% FRESH AIR UNIT - AAON MODEL RE -08 1700 CFM AT 0.5" E.S.P. COOL E.A.T. 94/78 L.A.T. 64.7/64.6 TOTAL COOL CAPACITY = 90,243 BTU /HR SENS = 54,044 BTU /HR NAT GAS HEAT INPUT = 173 MBH OUTPUT = 140 MBH HEAT E.A.T. -2/ L.A.T. 74/ 1 H.P. EVAP FAN MOTOR UNIT MCA AT 44A AT 208/30 FACTORY SINGLE PKG. PIPED WIRED AND TESTED. DUAL COMP. CKTS NTH ROW SPLIT DX COIL. HOT GAS BYPASS, 5 MIN. ANTI RECYCLE TIMERS AND 20 SEC. TIMER BETWEEN COMP ADJ COMP LOCKOUT THERMOSTAT EACH CIRCUIT, CRANKCASE HEATERS. MAN H1 RESET AND AUTO LOW RESET, 2 -STAGE SS HEAT EXCHANGER, 2 -STAGE DISCH. HEATING OVERRIDE THERMOSTAT, HEATING /COOL LOCKOUT INTERLOCK, ADJ V -BELT DRIVE BLOWER, SUPPLY AIR SMOKE DETECTOR. 100% O.S.A. HOOD WITH BIRD SCREEN, 30% PLEATED FILTERS, HOT GAS REHEAT COIL FOR HUMIDITY CONTROL, 30" FACTORY INSULATED 5 YEAR WARRANTY AND PRO RATED 6 TO 10 YEARS. ALL CONTROLS FOR COMPLETE OPERATION INSTALLED BY MANUFACTURER. FURNISH FOR FIELD MOUNTING T874 D THERMOSTAT, Q674C SUB BASE WITH LOCK COVER AND HUMIDISTAT WITH LOCK COVER. FOR ADDITIONAL INFORMATION ON THIS UNIT CONTACT GORHAM /SCHAFFLER INC., MEMPHIS, TENNESSEE AT 901- 345 -6100. 3. INDIVIDUAL ROOM TYPE HEATING AND AIR CONDITIONING UNITS - (PTAC) MCQUAY SUITE OR EQUAL SERIES 09 208/10 (TYPE "A "2 NOM 9000 BTU /HR COOLING WITH 30 KW ELECTRIC HEATER. (TYPE B ") NOM 14000 BTU /HR PROVIDE WITH SUB BASE AND INTERNAL DRAIN KIT. 4. GAS UNIT HEATER NO. 1 - STERLING OR EQUAL PROP TYPE NAT GAS INPUT 30 MBH 120V. 5. EXHAUST FANS - GREENHECK OR EQUAL ALUMINUM CENTRIFUGAL EXHAUSTERS 120V NOM PROVIDE WITH B.D. DMPR, BIRD SCREEN AND DISC. SWITCH. PROVIDE ROOF CURBS FOR ROOF FANS. 4 FAN NO. CFM 3 -P TYPE MODEL REMARKS 1 THRU 4 600 .250 ROOF GB -90 -4 BATHROOMS 5 650 .250 ROOF GB -90 -4 BATHROOMS 6 600 .250 ROOF GB -90 -4 BATH & PREP 7 450 .250 ROOF GB -90 -4 BATHROOMS 8 900 .250 ROOF GB -90 -4 BATHROOMS W1 660 .250 WALL GW -90 -D PUB. TOILETS W2 1200 .250 WALL GW -90 -A LAUNDRY / /C/??& 0 9 Z""' 1 ;.