REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
MI
2
0
0
.
d
g
n
1
0
:
3
7
:
4
1
A
M
4
/
1
0
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
4
/
1
0
/
2
0
1
2
MO
D
E
L
:
U
n
t
i
t
l
e
d
S
h
e
e
t
r
j
s
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
EQUIPMENT
ELEVATOR
LOBBY
STORAGE
STAIR ’D’
STAIR ’C’
PARKING
PARKING
# 1
ELEV.
# 2
ELEV.
ELECTRICAL
RJS
NOT TO SCALE
FRESH AIR INTAKE
FAN IS OFF
- DAMPERS CLOSED WHEN
FAN IS ON
- DAMPERS OPEN WHEN
EXHAUST FAN.
INTERLOCKED WITH
DETECTORS AND
CARBON MONOXIDE
CONTROLLED BY
MOTORIZED DAMPER
2
COLLAR & SLEEVE
MOUNTING
LOUVER
LEVELS DROP AWAY FROM LIMITS (SEE ABOVE)
- DAMPER CLOSES AND FAN IS INDEXED OFF AS CONTAMINANT
CONTAMINANT LEVELS APPROACH LIMITS (SEE ABOVE)
- DAMPER OPENS AND FAN IS INDEXED ON AS
NITROGEN DIOXIDE LEVELS BELOW 1 PPM
MAINTAIN CARBON MONOXIDE LEVELS BELOW 25 PPM AND
- CONTINUOUS MONITORING AND DETECTION SYSTEM TO
---------------
OPERATION
DAMPER
- EXHAUST FAN AND MOTORIZED VENTILATION INTAKE
----------------------------
SYSTEM CONTROLS:
--------------------------------------------------------
SEQUENCE OF OPERATION - GARAGE VENTILATION
GRADE
BY OTHERS
GRAVEL DRAIN BASE
BY OTHERS
AREA WELL
WITH GENERAL CONTRACTOR
OF LOUVER LOCATION
BY OTHERS. COORDINATE TOP
BOND BEAM OR PRECAST LINTEL
SLEEVE
SHEET METAL
MIN
12"
BY GC
PIPE BALLARDS
WALL
ADAPTER
CONCENTRIC
GENERAL CONTRACTOR )
( COORDINATE WITH
IN PRECAST PLANK
THRU BOLTED
1/2 " THREADED RODS
HEATER
UNIT
NO SCALE
UNIT HEATER INTAKE/VENTING DETAIL
MI200
3) SENSORS SHALL HAVE A MAX OPERATING RANGE OF 5000 SQ FT / SENSOR
OF AT LEAST FIVE HOURS FOR EACH 24-HOUR PERIOD
EXHAUST VENTILATION AT A RATE OF 1 1/2 CFM PER SQUARE FOOT FOR A TOTAL
2) THE SYSTEM SHALL BE PROVIDED WITH AUTOMATIC CONTROLS TO PROVIDE
BELOW ONE PPM
CARDON MONOXIDE LEVELS BELOW 25 PPM AND NITROGEN DIOXIDE LEVELS
A CONTINUOUS MONITORING AND DETECTION SYSTEM WHICH CAN MAINTAIN
1) THE SYSTEM SHALL BE ACTIVATED TO PROVIDE EXHAUST VENTILATION BY
IN THE GARAGE:
CONDITIONS FOR THE INTERMITTENT MECHANICAL EXHAUST VENTILATION SYSTEM
2
30,392 CFM
120Wx84H
LV-1
120x84
NUT & FENDER WASHERINLET ASSEMBLY
COMBUSTION AIR
ASSEMBLY
VENT TERMINAL
- SEAL ALL JOINTS
-INSTALL PER MANUFACTUERS INSTRUCTIONS
NOTES:
BY OTHERS
AREA WELL
FLOOR
1
1
UH-1
UNIT HEATER
PITCHED TOWARDS
5"‘ VENT
ADAPTER BOX
CONCENTRIC
UH-1
PIPE BALLARDS
BY GC
UNIT HEATER
PITCHED TOWARDS
5"‘ VENT
UH-1
1
1
MI200
MI200
MI200 MI200
MI200
MI200
DBU-1 1/2
LINE DOWN
3/4" CONDENSATE
FLOOR DRAIN BY OTHERS
LINE TO FLOOR DRAIN.
3/4" CONDENSATE
1/8" PARKING LEVEL HVAC PLAN - WING C
P1
P1
IN THIS AREA
FOR ELECTRIC HEAT
SEE ELECTRICAL PLANS
12" MIN
4"‘ MIN
BOTH PIPES.
DRIP LEG ON
6" LONG
4"‘ MIN
CLEANOUT CAP.
THREADED
BY OTHERS
GRATING
UNIT HEATER
PITCHED TOWARDS
6"‘ INLET
PITCH TO HEATER
INLET & VENT PIPES
CONCRETE BLOCKS
MOUNT ON 8"
DCU-1 1/2
UNIT HEATER
PITCHED TOWARDS
6"‘ INLET
MATCHLINEMATCHLINE
P7
P5
P4
P6
2
MI200
SIMILAR
PARKING
UNDERGROUND
EXPANDED
ALT. BID # 10
UNIT HEATER
PITCHED TOWARDS
6"‘ INLET
UNIT HEATER
PITCHED TOWARDS
5"‘ VENT
ADAPTER BOX
CONCENTRIC
16 APRIL 2012
ADDENDUM #5 REV.
1
1
-RUNS CONTINUOUS
-PROVIDE FAN GUARD
-1875 CFM
-MOUNT BOTTOM OF FAN 18’ AFF
EF-2
AUTO DAMPER
120x84
ABOVE FLOOR
MOUNT 60"
1875 CFM
30Wx24H
LV-1
BOTTOM OF OPENING TO BE 12" ABOVE GRATING
GOOSENECK WITH SCREENED OPENING.
20x14 UP THRU GRATING. PROVIDE
20x20
BOTTOM OF OPENING TO BE 12" ABOVE GRATING
GOOSENECK WITH SCREENED OPENING.
20x16 UP THRU GRATING. PROVIDE
DOWN 90 DEG.
6"‘ INLET TURN
OPEN
5"‘ VENT
1/2" MESH SCREEN
30x24 OPEN WITH
-RUNS CONTINUOUS
-PROVIDE FAN GUARD
-2429 CFM
-MOUNT BOTTOM OF FAN 18’ AFF
EF-2A PARKING
UNDERGROUND
EXPANDED
ALT. BID # 10