Loading...
HomeMy WebLinkAbout002 MI200 Addendum 5REV.pdfCC CC CC CC T T T 64636261605958575655535251 2 4 7 2 7 1 7 0 6 9 6 8 6 7 65 34353637383940414243444546474849 2 8 2 7 2 6 2 5 3 2 3 1 3 0 2 9 33 50 54 6 6 1 4 1 14 2 1 4 3 1 1 0 1 11 1 1 2 1 1 3 REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l In d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l INDEPENDENTINDEPENDENT C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ MI 2 0 0 . d g n 1 0 : 3 7 : 4 1 A M 4 / 1 0 / 2 0 1 2 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 4 / 1 0 / 2 0 1 2 MO D E L : U n t i t l e d S h e e t r j s B Y U S E R : A T S C A L E : U S I N G D R I V E R : D R A W I N G L I M I T L I N E 01 AUG 2011 FAX TEL EQUIPMENT ELEVATOR LOBBY STORAGE STAIR ’D’ STAIR ’C’ PARKING PARKING # 1 ELEV. # 2 ELEV. ELECTRICAL RJS NOT TO SCALE FRESH AIR INTAKE FAN IS OFF - DAMPERS CLOSED WHEN FAN IS ON - DAMPERS OPEN WHEN EXHAUST FAN. INTERLOCKED WITH DETECTORS AND CARBON MONOXIDE CONTROLLED BY MOTORIZED DAMPER 2 COLLAR & SLEEVE MOUNTING LOUVER LEVELS DROP AWAY FROM LIMITS (SEE ABOVE) - DAMPER CLOSES AND FAN IS INDEXED OFF AS CONTAMINANT CONTAMINANT LEVELS APPROACH LIMITS (SEE ABOVE) - DAMPER OPENS AND FAN IS INDEXED ON AS NITROGEN DIOXIDE LEVELS BELOW 1 PPM MAINTAIN CARBON MONOXIDE LEVELS BELOW 25 PPM AND - CONTINUOUS MONITORING AND DETECTION SYSTEM TO --------------- OPERATION DAMPER - EXHAUST FAN AND MOTORIZED VENTILATION INTAKE ---------------------------- SYSTEM CONTROLS: -------------------------------------------------------- SEQUENCE OF OPERATION - GARAGE VENTILATION GRADE BY OTHERS GRAVEL DRAIN BASE BY OTHERS AREA WELL WITH GENERAL CONTRACTOR OF LOUVER LOCATION BY OTHERS. COORDINATE TOP BOND BEAM OR PRECAST LINTEL SLEEVE SHEET METAL MIN 12" BY GC PIPE BALLARDS WALL ADAPTER CONCENTRIC GENERAL CONTRACTOR ) ( COORDINATE WITH IN PRECAST PLANK THRU BOLTED 1/2 " THREADED RODS HEATER UNIT NO SCALE UNIT HEATER INTAKE/VENTING DETAIL MI200 3) SENSORS SHALL HAVE A MAX OPERATING RANGE OF 5000 SQ FT / SENSOR OF AT LEAST FIVE HOURS FOR EACH 24-HOUR PERIOD EXHAUST VENTILATION AT A RATE OF 1 1/2 CFM PER SQUARE FOOT FOR A TOTAL 2) THE SYSTEM SHALL BE PROVIDED WITH AUTOMATIC CONTROLS TO PROVIDE BELOW ONE PPM CARDON MONOXIDE LEVELS BELOW 25 PPM AND NITROGEN DIOXIDE LEVELS A CONTINUOUS MONITORING AND DETECTION SYSTEM WHICH CAN MAINTAIN 1) THE SYSTEM SHALL BE ACTIVATED TO PROVIDE EXHAUST VENTILATION BY IN THE GARAGE: CONDITIONS FOR THE INTERMITTENT MECHANICAL EXHAUST VENTILATION SYSTEM 2 30,392 CFM 120Wx84H LV-1 120x84 NUT & FENDER WASHERINLET ASSEMBLY COMBUSTION AIR ASSEMBLY VENT TERMINAL - SEAL ALL JOINTS -INSTALL PER MANUFACTUERS INSTRUCTIONS NOTES: BY OTHERS AREA WELL FLOOR 1 1 UH-1 UNIT HEATER PITCHED TOWARDS 5"‘ VENT ADAPTER BOX CONCENTRIC UH-1 PIPE BALLARDS BY GC UNIT HEATER PITCHED TOWARDS 5"‘ VENT UH-1 1 1 MI200 MI200 MI200 MI200 MI200 MI200 DBU-1 1/2 LINE DOWN 3/4" CONDENSATE FLOOR DRAIN BY OTHERS LINE TO FLOOR DRAIN. 3/4" CONDENSATE 1/8" PARKING LEVEL HVAC PLAN - WING C P1 P1 IN THIS AREA FOR ELECTRIC HEAT SEE ELECTRICAL PLANS 12" MIN 4"‘ MIN BOTH PIPES. DRIP LEG ON 6" LONG 4"‘ MIN CLEANOUT CAP. THREADED BY OTHERS GRATING UNIT HEATER PITCHED TOWARDS 6"‘ INLET PITCH TO HEATER INLET & VENT PIPES CONCRETE BLOCKS MOUNT ON 8" DCU-1 1/2 UNIT HEATER PITCHED TOWARDS 6"‘ INLET MATCHLINEMATCHLINE P7 P5 P4 P6 2 MI200 SIMILAR PARKING UNDERGROUND EXPANDED ALT. BID # 10 UNIT HEATER PITCHED TOWARDS 6"‘ INLET UNIT HEATER PITCHED TOWARDS 5"‘ VENT ADAPTER BOX CONCENTRIC 16 APRIL 2012 ADDENDUM #5 REV. 1 1 -RUNS CONTINUOUS -PROVIDE FAN GUARD -1875 CFM -MOUNT BOTTOM OF FAN 18’ AFF EF-2 AUTO DAMPER 120x84 ABOVE FLOOR MOUNT 60" 1875 CFM 30Wx24H LV-1 BOTTOM OF OPENING TO BE 12" ABOVE GRATING GOOSENECK WITH SCREENED OPENING. 20x14 UP THRU GRATING. PROVIDE 20x20 BOTTOM OF OPENING TO BE 12" ABOVE GRATING GOOSENECK WITH SCREENED OPENING. 20x16 UP THRU GRATING. PROVIDE DOWN 90 DEG. 6"‘ INLET TURN OPEN 5"‘ VENT 1/2" MESH SCREEN 30x24 OPEN WITH -RUNS CONTINUOUS -PROVIDE FAN GUARD -2429 CFM -MOUNT BOTTOM OF FAN 18’ AFF EF-2A PARKING UNDERGROUND EXPANDED ALT. BID # 10