Loading...
HomeMy WebLinkAbout004 EI213 Addendum 5REV.pdfEI213 TJL/TAR 1/8" FIRST FLOOR POWER & SYSTEMS PLAN 1.1 DELUXE 1507 2.2 GRAND 1505 STAIR ’A’ 2.2 CORNER 1508 2.2TRAD. 1503 1501 1.1 DELUXE 1506 1.1.5 DELUXE 1.1.5 DELUXE 1504 1.1.5 DELUXE 1502 DELUXE 1.1.5 1406 DELUXE 1.1.5 1404 1402 2.2 CORNER2.2 GRAND 1408 1407 2.2 GRAND STAIR ’B’ 2.2TRAD. 1405 STANDARD 2.2 1403 1401 1.1 TRAD. DINING CATERED A114 CATERED COMMONS A108 A103 I.T. A102 STORAGE RESIDENT A104 A105 CORRIDOR A110 CORRIDOR STORAGE RESIDENT A109 A101 LAUNDRY B101 CORRIDOR XXXX B103 B102 XXXX HOUSE PANEL ’RAA’ - FIRST FLOOR RESIDENT APARTMENT SMOKE DETECTOR - ALTERNATE #1 LOCATED IN THE UNIT BATHROOM - ACCESSABLE UNITS TO HAVE AN ADDITIONAL AUDIO/VISUAL FIRE ALARM BEDROOMS AND LIVING SPACE - ACCESSABLE UNITS TO HAVE AUDIO / VISUAL FIRE ALARMS AT AT BEDROOMS AND LIVING SPACE - APARTMENT UNITS TO BE EQUIPPED W/ SYSTEM MINI HORN FIRE ALARMS SOUND A GENERAL ALARM AND AUTO-DIAL THE FIRE DEPARTMENT. ASSESS THE EVENT. PAST THE DELAY TIME PERIOD THE SYSTEM WILL DETERMINED BY THE OWNER / OPERATOR TO ALLOW FOR STAFF TO PAGER SYSTEM AND DELAY GENERAL ALARM BY A TIME PERIOD TO BE - MODULE TO BE PROGAMMED TO LOCALLY ANNUNCIATE EVENT TO STAFF FIRE ALARM SYSTEM MONITOR MODULE. - SMOKE DETECTOR WITH TYPE ’C’ CONTACTS TO BE CONNECTED TO - (1) SMOKE DETECTOR TO HAVE TYPE ’C’ AUXILLIARY CONTACTS WITH BATTERY BACK-UP. SMOKE DETECTORS TO BE INTERCONNECTED - UNIT SMOKE DETECTORS TO BE STAND ALONE TYPE, LINE VOLTAGE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE SERVES FIRST AND SECOND FLOOR COMMON SPACES 600 AMP - 3P - 120/208 V - 3‘ - 4 WIRE E H D A B KEYED NOTES THIS SHEET ONLY L M N P R C - CABLE TV - TELEPHONE (4) 4" CONDUITS AT FLOOR 120V - 1‘ - 20AMP - 1P CIRCUIT (RAA-44) -W/ (2) 4-PLEX RECEPTACLES WHITE AND BOLTED TO WALL TO 8’ A.F.F. 3/4" PLYWOOD PANEL PAINTED TELEPHONE/CABLE EQUIPMENT PANELS 20 AMP - 1P CIRCUIT (RAA-45) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-3 (SO-71) F 20 AMP - 1P CIRCUIT (RAA-47) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-1 1/2 (SO-72) G J K 20 AMP - 1P CIRCUIT (RAA-53) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-2 1/2 (SO-78) 20 AMP - 1P CIRCUIT (RAA-55) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-4 (SO-79) 15 AMP - 1P CIRCUIT (RAA-51) 120V - 1‘ - MCA = 2.6 AMP EXHAUST FAN EF-4 (SO-73) 15 AMP - 1P CIRCUIT (RAA-51) 120V - 1‘ - MCA = 2.1 AMP EXHAUST FAN EF-8 (SO-75) 15 AMP - 1P CIRCUIT (RAA-51) 120V - 1‘ - MCA = 1.3 AMP EXHAUST FAN EF-7 (SO-74) 15 AMP - 1P CIRCUIT (RAA-51) 120V - 1‘ - MCA = 1.3 AMP EXHAUST FAN EF-7 (SO-76) S PAGER SYSTEM ALARM ANNUNCIATOR PANELS AND STAFF FIRE ALARM SYSTEM AND ANNUNCIATE AT CO DETECTOR TO BE CONNECTED TO INSTALLED BY FIRE ALARM CONTRACTOR - CARBON MONOXIDE DETECTOR PROVIDED AND T V DETECTOR MAY BE USED COMBINATION SMOKE DETECTOR / CO PAGER SYSTEM ALARM ANNUNCIATOR PANELS AND STAFF INDIVIDUAL APARTMENT UNIT AND AT FIRE ALARM SYSTEM AND ANNUNCIATE AT CO DETECTOR TO BE CONNECTED TO INSTALLED BY FIRE ALARM CONTRACTOR - CARBON MONOXIDE DETECTOR PROVIDED AND W X Y Z AA EFG T H S V V V V (RAA-48) A DBC V V V V V VV V L V V V J V TK T T M N P T (RAA-54) (RAA-52) MECH A GFI/WP (RAA-78) 20AMP - 1P CIRCUITS (RAA-43) 120V - 1‘ - 100 WATTS VERIFY W/ F.A. CONTRACTOR FIRE ALARM NAC PANEL (SO-70) G 20 AMP - 1P CIRCUIT (RAA-61) 120V - 1‘ - MCA = 1500 WATTS ELECTRIC FIREPLACE (SO-77) ELECTRICAL INSTALLATION) ERS PROVIDER PRIOR TO START OF (VERIFY QUANTITY AND LOCATION W/ 20AMP - 1P CIRCUIT (RAA-46) 120V - 1‘ - 200W RECEIVER/TRANSMITTER RESPONSE CALL SYSTEM (ERS) @7’ A.F.F. FOR WIRELESS EMERGENCY (2) DUPLEX RECEPTACLES W/10"x10" J-BOX S 20 AMP - 2P CIRCUIT (RAA-57,59) 208V - 1‘ - 1500 WATTS EACH W/ BUILT-IN THERMOSTAT (2) ELECTRIC BASEBOARD - BB-6 20 AMP - 2P CIRCUIT (RAA-57,59) 208V - 1‘ - 1500 WATTS EACH W/ BUILT-IN THERMOSTAT (2) ELECTRIC BASEBOARD - BB-6 W W 20AMP - 1P CIRCUIT (RAA-67) 120V - 1‘ - 1200 WATTS REFRIGERATOR 20 AMP - 1P - CIRCUIT (RAA-69) 120V - 1‘ - 8.6 AMPS DISHWASHER 20 AMP - 1P - CIRCUIT (RAA-71) 120V - 1‘ - 7.2 AMPS RANGEHOOD W/ WALL SWITCH 40AMP - 2P CIRCUIT (RAA-73,75) 208V - 1‘ - 8000 WATTS ELECTRIC RANGE X Y ZAA (RAA-48) (RAA-48) (RAA-48) (RAA-48) (RAA-48)(RAA-48) (RAA-48) (RAA-48) GFI GFI GFI GFI GFI (RAA-50)(RAA-50) (RAA-50) (RAA-52) (RAA-52) (RAA-52) (RAA-52) (RAA-52) (RAA-52) (RAA-52)(RAA-52) (RAA-54) (RAA-54) (RAA-54) (RAA-54) (RAA-54) (RAA-54) (RAA-54) (RAA-50) GFI GFI GFI AB 20 AMP - 1P CIRCUIT (RAA-68) 120V - 1‘ - 350 WATTS SEE ARCHITECTURAL ELEV. FOR MOUNTING HT. BY OWNER - VERIFY MOUNTING, POWER ETC. WALL MOUNT FLAT PANEL TV UNIT PROVIDED AB (RAA-70)(RAA-70)(RAA-70) (RAA-70) (RAA-72) (RAA-72) (RAA-72) (RAA-72) (RAA-74)(RAA-74)(RAA-74)(RAA-74)(RAA-76)(RAA-76) GFI/WP (RAA-78) AC 1200 AMP - 3P - 120/208 V - 3‘ - 4 WIRE APARTMENT DISTRIBUTION PANEL RADP-A/B (ESTIMATED) 3 - 125 AMP - 3P - LOADCENTER 2.2 GRAND 3 UNIT STACK 2 - 125 AMP - 3P - LOADCENTER 2.2 CORNER 3 UNIT STACK 2 - 125 AMP - 3P - LOADCENTER 2.2 TRADITIONAL 3 UNIT STACK 1 - 125 AMP - 3P - LOADCENTER 2.2 STANDARD 3 UNIT STACK 5 - 125 AMP - 3P - LOADCENTER 1.15 DELUXE 3 UNIT STACK 1 - 125 AMP - 3P - LOADCENTER 1.1 TRADITIONAL 3 UNIT STACK 1 - 150 AMP - 3P - LOADCENTER 1.1 DELUXE 2 UNIT STACK 4 - 100 AMP - 3P - LOADCENTER 1.1 DELUXE 3 UNIT STACK 1 ADDENDUM #3 25 AUG 2011 1 1 1 1 1 1 A115 STORAGE 20 AMP - 2P CIRCUIT (RAC-27,29) 208V - 1‘ - 1500 WATTS W/ BUILT-IN THERMOSTAT ELECTRIC BASEBOARD - BB-6 (RAC-36) AD AD 2 2 AB 2 G 15AMP - 1P CIRCUIT (RAA-49) 120V - 1‘ - 0.5 AMPS MOTORIZED SMOKE OR FIRE/SMOKE DAMPER2 2 (RAA-54) 1 A112 MECH 16 APRIL 2012 ADDENDUM #5 REV. 2 REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l INDEPENDENTINDEPENDENT C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ E I 2 1 3 . d g n 1 1 : 5 0 : 3 9 A M 4 / 1 3 / 2 0 1 2 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 4 / 1 3 / 2 0 1 2 MO D E L : D e f a u l t t a r B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL F VA T T T S S F VA F VA FVA F F SS S S S S S S S S S S S T F VAFVA F VA F VA F VA F VA FVA FVA MM MM MM MM MM MM MM MM MM MMMM MM MM MM MM MM S F M S F M C S S F M S F M C S S S C S FM S S F M C S FM F M S C S S F M FM S SS C S C S F M F M FM SC S S F M FM FM F M S S S S S S C C SC SFM S CS F M S S C S F M F M F M S C S S F M F M S C S S F M F M S C S S 4 4 S C C TV C C C C M M S M M S S F VA F VA F VA F VA F VA F VA F VA FVA T F VA TV