HomeMy WebLinkAbout004 EI213 Addendum 5REV.pdfEI213
TJL/TAR
1/8" FIRST FLOOR POWER & SYSTEMS PLAN
1.1 DELUXE
1507
2.2 GRAND
1505
STAIR ’A’
2.2 CORNER
1508
2.2TRAD.
1503
1501
1.1 DELUXE
1506
1.1.5 DELUXE
1.1.5 DELUXE
1504
1.1.5 DELUXE
1502
DELUXE
1.1.5
1406
DELUXE
1.1.5
1404 1402
2.2 CORNER2.2 GRAND
1408
1407
2.2 GRAND
STAIR ’B’
2.2TRAD.
1405
STANDARD
2.2
1403 1401
1.1 TRAD.
DINING
CATERED
A114
CATERED COMMONS
A108
A103
I.T.
A102
STORAGE
RESIDENT
A104
A105
CORRIDOR
A110
CORRIDOR
STORAGE
RESIDENT
A109
A101
LAUNDRY
B101
CORRIDOR
XXXX
B103 B102
XXXX
HOUSE PANEL ’RAA’ - FIRST FLOOR
RESIDENT APARTMENT SMOKE DETECTOR - ALTERNATE #1
LOCATED IN THE UNIT BATHROOM
- ACCESSABLE UNITS TO HAVE AN ADDITIONAL AUDIO/VISUAL FIRE ALARM
BEDROOMS AND LIVING SPACE
- ACCESSABLE UNITS TO HAVE AUDIO / VISUAL FIRE ALARMS AT
AT BEDROOMS AND LIVING SPACE
- APARTMENT UNITS TO BE EQUIPPED W/ SYSTEM MINI HORN FIRE ALARMS
SOUND A GENERAL ALARM AND AUTO-DIAL THE FIRE DEPARTMENT.
ASSESS THE EVENT. PAST THE DELAY TIME PERIOD THE SYSTEM WILL
DETERMINED BY THE OWNER / OPERATOR TO ALLOW FOR STAFF TO
PAGER SYSTEM AND DELAY GENERAL ALARM BY A TIME PERIOD TO BE
- MODULE TO BE PROGAMMED TO LOCALLY ANNUNCIATE EVENT TO STAFF
FIRE ALARM SYSTEM MONITOR MODULE.
- SMOKE DETECTOR WITH TYPE ’C’ CONTACTS TO BE CONNECTED TO
- (1) SMOKE DETECTOR TO HAVE TYPE ’C’ AUXILLIARY CONTACTS
WITH BATTERY BACK-UP. SMOKE DETECTORS TO BE INTERCONNECTED
- UNIT SMOKE DETECTORS TO BE STAND ALONE TYPE, LINE VOLTAGE
DETECTOR AND THE BUILDING FIRE ALARM SYSTEM
NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE
DETECTOR AND THE BUILDING FIRE ALARM SYSTEM
NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE
SERVES FIRST AND SECOND FLOOR COMMON SPACES
600 AMP - 3P - 120/208 V - 3‘ - 4 WIRE
E
H
D
A
B
KEYED NOTES THIS SHEET ONLY
L
M
N
P
R
C
- CABLE TV
- TELEPHONE
(4) 4" CONDUITS AT FLOOR
120V - 1‘ - 20AMP - 1P CIRCUIT (RAA-44)
-W/ (2) 4-PLEX RECEPTACLES
WHITE AND BOLTED TO WALL TO 8’ A.F.F.
3/4" PLYWOOD PANEL PAINTED
TELEPHONE/CABLE EQUIPMENT PANELS
20 AMP - 1P CIRCUIT (RAA-45)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-3 (SO-71)
F
20 AMP - 1P CIRCUIT (RAA-47)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-1 1/2 (SO-72)
G
J
K
20 AMP - 1P CIRCUIT (RAA-53)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-2 1/2 (SO-78)
20 AMP - 1P CIRCUIT (RAA-55)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-4 (SO-79)
15 AMP - 1P CIRCUIT (RAA-51)
120V - 1‘ - MCA = 2.6 AMP
EXHAUST FAN EF-4 (SO-73)
15 AMP - 1P CIRCUIT (RAA-51)
120V - 1‘ - MCA = 2.1 AMP
EXHAUST FAN EF-8 (SO-75)
15 AMP - 1P CIRCUIT (RAA-51)
120V - 1‘ - MCA = 1.3 AMP
EXHAUST FAN EF-7 (SO-74)
15 AMP - 1P CIRCUIT (RAA-51)
120V - 1‘ - MCA = 1.3 AMP
EXHAUST FAN EF-7 (SO-76)
S
PAGER SYSTEM
ALARM ANNUNCIATOR PANELS AND STAFF
FIRE ALARM SYSTEM AND ANNUNCIATE AT
CO DETECTOR TO BE CONNECTED TO
INSTALLED BY FIRE ALARM CONTRACTOR -
CARBON MONOXIDE DETECTOR PROVIDED AND
T
V
DETECTOR MAY BE USED
COMBINATION SMOKE DETECTOR / CO
PAGER SYSTEM
ALARM ANNUNCIATOR PANELS AND STAFF
INDIVIDUAL APARTMENT UNIT AND AT
FIRE ALARM SYSTEM AND ANNUNCIATE AT
CO DETECTOR TO BE CONNECTED TO
INSTALLED BY FIRE ALARM CONTRACTOR -
CARBON MONOXIDE DETECTOR PROVIDED AND
W
X
Y
Z
AA
EFG
T
H
S
V
V V
V
(RAA-48)
A
DBC
V V V
V
V VV V
L
V
V
V
J
V
TK
T
T
M
N P
T
(RAA-54)
(RAA-52)
MECH
A
GFI/WP
(RAA-78)
20AMP - 1P CIRCUITS (RAA-43)
120V - 1‘ - 100 WATTS
VERIFY W/ F.A. CONTRACTOR
FIRE ALARM NAC PANEL (SO-70)
G
20 AMP - 1P CIRCUIT (RAA-61)
120V - 1‘ - MCA = 1500 WATTS
ELECTRIC FIREPLACE (SO-77)
ELECTRICAL INSTALLATION)
ERS PROVIDER PRIOR TO START OF
(VERIFY QUANTITY AND LOCATION W/
20AMP - 1P CIRCUIT (RAA-46)
120V - 1‘ - 200W
RECEIVER/TRANSMITTER
RESPONSE CALL SYSTEM (ERS)
@7’ A.F.F. FOR WIRELESS EMERGENCY
(2) DUPLEX RECEPTACLES W/10"x10" J-BOX
S
20 AMP - 2P CIRCUIT (RAA-57,59)
208V - 1‘ - 1500 WATTS EACH
W/ BUILT-IN THERMOSTAT
(2) ELECTRIC BASEBOARD - BB-6
20 AMP - 2P CIRCUIT (RAA-57,59)
208V - 1‘ - 1500 WATTS EACH
W/ BUILT-IN THERMOSTAT
(2) ELECTRIC BASEBOARD - BB-6
W
W
20AMP - 1P CIRCUIT (RAA-67)
120V - 1‘ - 1200 WATTS
REFRIGERATOR
20 AMP - 1P - CIRCUIT (RAA-69)
120V - 1‘ - 8.6 AMPS
DISHWASHER
20 AMP - 1P - CIRCUIT (RAA-71)
120V - 1‘ - 7.2 AMPS
RANGEHOOD W/ WALL SWITCH
40AMP - 2P CIRCUIT (RAA-73,75)
208V - 1‘ - 8000 WATTS
ELECTRIC RANGE
X Y ZAA
(RAA-48)
(RAA-48)
(RAA-48)
(RAA-48)
(RAA-48)(RAA-48)
(RAA-48)
(RAA-48)
GFI GFI
GFI GFI GFI
(RAA-50)(RAA-50)
(RAA-50)
(RAA-52)
(RAA-52)
(RAA-52)
(RAA-52)
(RAA-52)
(RAA-52)
(RAA-52)(RAA-52)
(RAA-54)
(RAA-54)
(RAA-54)
(RAA-54)
(RAA-54)
(RAA-54)
(RAA-54)
(RAA-50)
GFI GFI GFI
AB
20 AMP - 1P CIRCUIT (RAA-68)
120V - 1‘ - 350 WATTS
SEE ARCHITECTURAL ELEV. FOR MOUNTING HT.
BY OWNER - VERIFY MOUNTING, POWER ETC.
WALL MOUNT FLAT PANEL TV UNIT PROVIDED
AB
(RAA-70)(RAA-70)(RAA-70)
(RAA-70)
(RAA-72)
(RAA-72)
(RAA-72)
(RAA-72)
(RAA-74)(RAA-74)(RAA-74)(RAA-74)(RAA-76)(RAA-76)
GFI/WP
(RAA-78)
AC
1200 AMP - 3P - 120/208 V - 3‘ - 4 WIRE
APARTMENT DISTRIBUTION PANEL RADP-A/B (ESTIMATED)
3 - 125 AMP - 3P - LOADCENTER 2.2 GRAND 3 UNIT STACK
2 - 125 AMP - 3P - LOADCENTER 2.2 CORNER 3 UNIT STACK
2 - 125 AMP - 3P - LOADCENTER 2.2 TRADITIONAL 3 UNIT STACK
1 - 125 AMP - 3P - LOADCENTER 2.2 STANDARD 3 UNIT STACK
5 - 125 AMP - 3P - LOADCENTER 1.15 DELUXE 3 UNIT STACK
1 - 125 AMP - 3P - LOADCENTER 1.1 TRADITIONAL 3 UNIT STACK
1 - 150 AMP - 3P - LOADCENTER 1.1 DELUXE 2 UNIT STACK
4 - 100 AMP - 3P - LOADCENTER 1.1 DELUXE 3 UNIT STACK
1 ADDENDUM #3
25 AUG 2011
1
1
1
1
1
1
A115
STORAGE
20 AMP - 2P CIRCUIT (RAC-27,29)
208V - 1‘ - 1500 WATTS
W/ BUILT-IN THERMOSTAT
ELECTRIC BASEBOARD - BB-6
(RAC-36)
AD
AD
2
2
AB
2
G
15AMP - 1P CIRCUIT (RAA-49)
120V - 1‘ - 0.5 AMPS
MOTORIZED SMOKE OR FIRE/SMOKE DAMPER2
2
(RAA-54)
1
A112
MECH
16 APRIL 2012
ADDENDUM #5 REV.
2
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
E
I
2
1
3
.
d
g
n
1
1
:
5
0
:
3
9
A
M
4
/
1
3
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
4
/
1
3
/
2
0
1
2
MO
D
E
L
:
D
e
f
a
u
l
t
t
a
r
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL
F VA
T
T
T
S
S
F VA
F VA
FVA
F
F
SS S S S S
S
S
S
S
S S S
T
F VAFVA
F VA
F VA
F VA
F VA
FVA
FVA
MM
MM
MM
MM
MM
MM
MM
MM
MM
MMMM
MM
MM
MM
MM
MM
S
F M
S
F M
C
S
S
F M
S
F M
C
S
S
S
C
S
FM
S
S
F M
C
S
FM
F M S C
S
S
F M
FM
S
SS
C
S C
S F M
F M
FM
SC
S
S
F M
FM
FM
F M
S
S
S S
S
S
C C
SC
SFM
S
CS
F M
S
S
C
S
F M
F M
F M
S
C
S
S
F M
F M
S
C
S
S
F M
F M
S
C
S
S
4
4
S
C
C
TV
C
C
C
C
M
M
S
M
M
S S
F VA
F VA
F VA
F VA
F VA
F VA
F VA
FVA
T
F VA
TV