HomeMy WebLinkAbout006 EI215 Addendum 5REV.pdfEI215
TJL/TAR
1/8" SECOND FLOOR POWER & SYSTEMS PLAN
RESIDENT APARTMENT SMOKE DETECTOR - ALTERNATE #1
LOCATED IN THE UNIT BATHROOM
- ACCESSABLE UNITS TO HAVE AN ADDITIONAL AUDIO/VISUAL FIRE ALARM
BEDROOMS AND LIVING SPACE
- ACCESSABLE UNITS TO HAVE AUDIO / VISUAL FIRE ALARMS AT
AT BEDROOMS AND LIVING SPACE
- APARTMENT UNITS TO BE EQUIPPED W/ SYSTEM MINI HORN FIRE ALARMS
SOUND A GENERAL ALARM AND AUTO-DIAL THE FIRE DEPARTMENT.
ASSESS THE EVENT. PAST THE DELAY TIME PERIOD THE SYSTEM WILL
DETERMINED BY THE OWNER / OPERATOR TO ALLOW FOR STAFF TO
PAGER SYSTEM AND DELAY GENERAL ALARM BY A TIME PERIOD TO BE
- MODULE TO BE PROGAMMED TO LOCALLY ANNUNCIATE EVENT TO STAFF
FIRE ALARM SYSTEM MONITOR MODULE.
- SMOKE DETECTOR WITH TYPE ’C’ CONTACTS TO BE CONNECTED TO
- (1) SMOKE DETECTOR TO HAVE TYPE ’C’ AUXILLIARY CONTACTS
WITH BATTERY BACK-UP. SMOKE DETECTORS TO BE INTERCONNECTED
- UNIT SMOKE DETECTORS TO BE STAND ALONE TYPE, LINE VOLTAGE
DETECTOR AND THE BUILDING FIRE ALARM SYSTEM
NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE
DETECTOR AND THE BUILDING FIRE ALARM SYSTEM
NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE
E
H
D
A
B
KEYED NOTES THIS SHEET ONLY
L
M
N
P
R
C
- CABLE TV
- TELEPHONE
(4) 4" CONDUITS AT FLOOR
120V - 1‘ - 20AMP - 1P CIRCUIT (RAA-2)
-W/ (2) 4-PLEX RECEPTACLES
WHITE AND BOLTED TO WALL TO 8’ A.F.F.
3/4" PLYWOOD PANEL PAINTED
TELEPHONE/CABLE EQUIPMENT PANELS
20 AMP - 1P CIRCUIT (RAA-9)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-3 (SO-57)
F
20 AMP - 1P CIRCUIT (RAA-11)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-1 1/2 (SO-58)
G
J
K
20 AMP - 1P CIRCUIT (RAA-17)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-2 1/2 (SO-64)
20 AMP - 1P CIRCUIT (RAA-19)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-4 (SO-65)
15 AMP - 1P CIRCUIT (RAA-15)
120V - 1‘ - MCA = 2.6 AMP
EXHAUST FAN EF-4 (SO-59)
15 AMP - 1P CIRCUIT (RAA-15)
120V - 1‘ - MCA = 2.1 AMP
EXHAUST FAN EF-8 (SO-61)
15 AMP - 1P CIRCUIT (RAA-15)
120V - 1‘ - MCA = 1.3 AMP
EXHAUST FAN EF-7 (SO-60)
15 AMP - 1P CIRCUIT (RAA-15)
120V - 1‘ - MCA = 1.3 AMP
EXHAUST FAN EF-7 (SO-62)
15 AMP - 1P CIRCUIT (RAA-15)
120V - 1‘ - MCA = 1.8 AMP
EXHAUST FAN EF-5 (SO-63)
S
20 AMP - 2P CIRCUIT (RAA-21,23)
208V - 1‘ - 1500 WATTS
W/ BUILT-IN THERMOSTAT
ELECTRIC BASEBOARD - BB-6
PAGER SYSTEM
ALARM ANNUNCIATOR PANELS AND STAFF
FIRE ALARM SYSTEM AND ANNUNCIATE AT
CO DETECTOR TO BE CONNECTED TO
INSTALLED BY FIRE ALARM CONTRACTOR -
CARBON MONOXIDE DETECTOR PROVIDED AND
T
V
DETECTOR MAY BE USED
COMBINATION SMOKE DETECTOR / CO
PAGER SYSTEM
ALARM ANNUNCIATOR PANELS AND STAFF
INDIVIDUAL APARTMENT UNIT AND AT
FIRE ALARM SYSTEM AND ANNUNCIATE AT
CO DETECTOR TO BE CONNECTED TO
INSTALLED BY FIRE ALARM CONTRACTOR -
CARBON MONOXIDE DETECTOR PROVIDED AND
20 AMP - 1P CIRCUIT (RAA-25)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-4 (SO-66)
A
D
BC
EFG
T
H
S
V
V V
V V V
V
V VV V
L
V
V
J
V
V
T
K
T
T
M
N P
30 AMP - 2P - CIRCUIT (RAA-26,28)
208V - 1‘ - 5.0 KW
DRYER
30 AMP - 2P - CIRCUIT (RAA-30,32)
208V - 1‘ - 5.0 KW
DRYER
W
X
Y
Z
Z
20 AMP - 1P - CIRCUIT (RAA-38)
120V - 1‘ - 1.2 KW
IRONING CENTER
20 AMP - 1P - CIRCUIT (RAA-34)
120V - 1‘ - 500 WATTS
AUTOMATIC WASHER
20 AMP - 1P - CIRCUIT (RAA-36)
120V - 1‘ - 500 WATTS
AUTOMATIC WASHER
W XY Z
Z
T
20AMP - 1P CIRCUITS (RAA-7)
120V - 1‘ - 100 WATTS
VERIFY W/ F.A. CONTRACTOR
FIRE ALARM NAC PANEL (SO-56)
ELECTRICAL INSTALLATION)
ERS PROVIDER PRIOR TO START OF
(VERIFY QUANTITY AND LOCATION W/
20AMP - 1P CIRCUIT (RAA-4)
120V - 1‘ - 200W
RECEIVER/TRANSMITTER
RESPONSE CALL SYSTEM (ERS)
@7’ A.F.F. FOR WIRELESS EMERGENCY
(2) DUPLEX RECEPTACLES W/10"x10" J-BOX
(RAA-6)(RAA-6)
(RAA-6)
(RAA-6)
(RAA-6)
(RAA-6)
(RAA-6)
(RAA-6)(RAA-6)
(RAA-6)
(RAA-8)
(RAA-8)(RAA-8)
(RAA-8)
(RAA-8)
(RAA-8)
(RAA-8)(RAA-8)
(RAA-10)
(RAA-10)
(RAA-10)
(RAA-10)
(RAA-10)
(RAA-12)
GFI
GFI
(RAA-12)
1.1 DELUXE
2507
2.2 GRAND
2505
STAIR ’A’
2.2 CORNER
2508
2.2TRAD.
2503
2501
1.1 DELUXE
2506
1.1.5 DELUXE
1.1.5 DELUXE
2504 DELUXE
1.1.5
2406
DELUXE
1.1.5
2404 2402
2.2 CORNER2.2 GRAND
2408
2407
2.2 GRAND
STAIR ’B’
2.2TRAD.
2405
STANDARD
2.2
2403 2401
1.1 TRAD.
A211
A206
A202
A204
A205
A110
A207
A201
B201
B203
B202
STORAGE
STORAGE
A2203
(RAA-70)(RAA-70)(RAA-70)
(RAA-70)
(RAA-72)
(RAA-72)
(RAA-72)
(RAA-72)
(RAA-74)(RAA-74)(RAA-74)(RAA-74)(RAA-76)(RAA-76)
A212
STORAGE
(RAA-6)
S
AA
20 AMP - 2P CIRCUIT (RAA-27,29)
208V - 1‘ - 1500 WATTS
W/ BUILT-IN THERMOSTATS
ELECTRIC BASEBOARDS - BB-6
1
1
MECH
STORAGE
RESIDENT
STORAGE
RESIDENT
CORRIDOR
XXXX
XXXX
CORRIDOR
LAUNDRY
I.T.
CORRIDOR
15AMP - 1P CIRCUIT (RAA-13)
120V - 1‘ - 0.5 AMPS
MOTORIZED SMOKE OR FIRE/SMOKE DAMPER
1
G
G
1
1
1
A212
MECH
1
1 16 APRIL 2012
ADDENDUM #5 REV.
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
E
I
2
1
5
.
d
g
n
1
1
:
4
9
:
1
6
A
M
4
/
1
3
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
4
/
1
3
/
2
0
1
2
MO
D
E
L
:
D
e
f
a
u
l
t
t
a
r
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL
F VA
F VA
FVA
F
F
SS S S S S
S
S
S
S
S S S
F VAFVA
F VAFVA
F VA
F VA
FVA
FVA
MM
MM
MM
F M
F M
S
C
S
S
F M
F M
S
C
S
S
F M
F M
S
C
S
S
MM
FM
F M S C
S
S
MM
MM
FMSC
SFM
S
CS
F M
S
MM
MM
S
S
C
S
F M
F M
S
C
S
F M
MM
MMMM
MM
S
F M
S
F M
C
S
F M
FM
SC
S
S
F M
FM
FM
F M
S
S
S S
S
S
C C
MM
MM
MM
MM
S
F M
S
F M
C
S
FM
S
S
F M
C
S
F M
FM
S
SS
C
S C
S F M
C
C
C
C
C
44
C
T
T
F VA