HomeMy WebLinkAbout006 PI211 Addendum 5REV.pdfB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
P
I
2
1
1
.
d
g
n
1
1
:
4
2
:
5
0
A
M
2
/
2
1
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
2
/
6
/
2
0
1
2
MO
D
E
L
:
U
n
t
i
t
l
e
d
S
h
e
e
t
j
a
w
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
B
B
B
A1
3/4" HWR
1 1/4" CW
1" HWA2
1/2" HW, CW
1 1/2" V. UP
2" W. DN.
A3 1/2"
3/4" HWR
1 1/2" CW
1 1/4" HW
1 1/4" HW, CW
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
A4
A5
1 1/4" CW
1" HW
3/4" HWR
1 1/2" CW
1 1/4" HW
3/4" HWR
1 1/4" HW, CW
3/4" HWR
A6
1 1/2" CW
1 1/4" HW
3/4" HWR
B1
3/4" HWR
1 1/2" CW
1 1/4" HW
3/4" HWR
1 1/2" CW
1 1/4" HW B2
1" HWR
1 1/2" HW
2" CW
3/4" HWR
1 1/2" CW
1 1/4" HW
3/4" HWR
1 1/4" CW
1" HW B3
2" HW, CW
1" HWR
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/2" CW
1 1/4" HW
B4
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1 1/4" HW B5
1/2" HW, CW DN.
1 1/2" V. UP
2" W. DN.
2" HW, CW
1" HWR
2 1/2" CW
2" HW
1" HWR
A7
3/4" HWR
1 1/2" CW
1 1/4" HW
A8
2.2 CORNER
1508
2.2TRAD.
1503
1.1 DELUXE
1501
1.1.5 DELUXE
1506
1.1.5 DELUXE
1504
1.1.5 DELUXE
1502
1.1 TRAD.
1401
STANDARD
2.2
1403
2.2 CORNER
1402
DELUXE
1.1.5
1404
DELUXE
1.1.5
1406
2.2TRAD.
1405
2.2 GRAND
1407
2.2 GRAND
1408
2.2 GRAND
1505
1.1 DELUXE
1507
S-4
S-3
GENERAL PLUMBING NOTES
STACK OF UNITS. PROVIDE VENTED REGULATOR AND SHUT-OFF AT EACH UNIT.
- GAS TO HVAC UNITS TO BE SUPPLED FROM ABOVE. EXTEND 3/4" (2 PSI) RISER UP TO EACH
TO FREEZING..
- WATER PIPING SHALL NOT BE LOCATED IN EXTERIOR WALLS, ATTIC OR ANY SPACE SUBJECT
IN DROPPED CEILING SPACES.
SPACE WITH APPROPRIATE FIRESTOPPING APPLIED. DUCTWORK TO HAVE SPACE PRIORITY
AS MUCH AS POSSIBLE. WHERE NECESSARY, PENETRATE UP OR DOWN INTO FLOOR TRUSS.
- WATER PIPING SHOWN WITHIN TYPICAL UNITS TO BE LOCATED IN DROPPED CEILING SPACE
- 3 HOUR RATING EXISTS BETWEEN RESIDENTIAL AND GARAGE.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS AND ROOF OR COMMONS.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS.
FOR WALL TYPES AND EXACT LOCATIONS OF RATED CONSTRUCTION.
TO MAINTAIN THE RATING OF THE CONSTRUCTION. REFER TO ARCHITECTURAL PLANS
PIPING (GROUTED TIGHT) OR SEALED WITH A U.L. APPROVED FIRE BARRIER SYSTEM
- ANY PENETRATION OF THE FIRE RATED CONSTRUCTION MUST BE MADE WITH METAL
CEILING SPACES.
JOIST SPACE WHERE POSSIBLE. DUCTWORK TO HAVE SPACE PRIORITY IN DROPPED
- LOCATE ABOVE GRADE DRAIN, VENT AND WATER DISTRIBUTION PIPING WITHIN CEILING
LAYOUTS WITHIN APARTMENT UNITS.
- REFER TO 1/4" TYPICAL UNIT PLUMBING PLANS FOR FIXTURE DESIGNATIONS AND PIPING
1/8" PARTIAL FIRST FLOOR PLUMBING PLAN PI211
TJL/JAW
STORAGE
A101
STORAGE
RESIDENT
A104
A102
I.T.
A103
MECH.
A105
CORRIDOR
A108
COMMONS
CATERED
STORAGE
RESIDENT
A109
A111
CORRIDOR
DINING
CATERED
A114
A112
MECH
STAIR ’B’
STAIR ’A’
A110
CORRIDOR
MATCH LINE
REFER TO PI225
B101
CORRIDOR
1 1/2" V.
1 1/2" V.
1 1/2" V.
HB-1
3/4"
HB-1
HB-1
3/4"
3/4"
3/4"
HB-1
HB-1
3/4"
3/4"
1 1/2" V. UP
1 1/4" HWR
2 1/2" HW, CW
1 1/4" HWR
2 1/2" HW, CW
1 1/4" HWR
2 1/2" HW, CW
1 1/4" HWR
2 1/2" HW, CW
1 1/4" HWR
2 1/2" HW
3" CW
1 1/4" HWR
3" HW, CW
1 1/4" HWR
4" CW
3" HW
1 1/4" HWR
4" CW
3" HW
ADDITION
FOR FUTURE
CAP PIPES
3/4" HWR
1 1/4" CW
1" HW
1
1
11
1
1
1
1
1
1
1
17 FEB 2012
ADDENDUM #5