HomeMy WebLinkAbout008 MI217.pdfMI217
2.2 GRAND
1308
1309
1.1 TRAD.
1307
1.1 DELUXE
1305 1303
1301
CORRIDOR
C101
1306
2.2 TRAD.
1304 1302
1.1 TRAD.
STORAGE
RESIDENT
106
D104
ELECTRICAL
103
105
MECH
CORRIDOR
C101
TV ROOM
D107
D101
CORRIDOR
D115
OFFICE
CRAFTS STUDIO
D109
STORAGE
OUTDOOR
D114
D110
KILN
LOBBY
D111
ELEV #1
ELEV #2
STAIR ’D’
D112
TRASH
C102
MECH
STAIR ’C’
102
I.T.
1.1.5 DELUXE
2.2 CORNER
STANDARD
2.2
1.1 DELUXE
1206
1.1.5 DELUXE
1207
1205
STANDARD
2.2
2.2 TRAD.
1203
1.1 DELUXE
1204
1.1 DELUXE
1202
RJS
1/8" FIRST FLOOR HVAC PLAN
200 CFM
8"ß NK
SG-1
8"‘ SVD
12x8 S
FD-B
VENTING UP
FURNACE
24x8 DOWN
-CONTINUOUS BLOWER OPERATION
150 CFM OUTSIDE AIR
450 CFM RETURN AIR
600 CFM SUPPLY AIR
-CU-1 1/2 ON ROOF
F-1 1/2 FURNACE
200 CFM
8"ß NK
SG-1
200 CFM
8"ß NK
SG-1
VD
VD
INSULATE
TRUSS SPACE
8"‘ OA IN
INSULATE
TRUSS SPACE
8"‘ OA IN
WC-3
1
6
x
8
S
1
6
x
8
R
8"‘ S
FD-B
FD-B
RD
8"‘ UP
BY HC
ACCESS PANEL
VD
FLEX
8"ß
VENTING UP
FURNACE
AD-1
FD-B
8
"‘
S
2
0
x
1
0
S
16x10 S NEAR FLOOR
600 CFM
18x12
RG-2
DOWN
24x10
1
8
x
1
0
S
1
8
x
1
0
S200 CFM
8"ß NK
SG-1
150 CFM
8"ß NK
SG-1
200 CFM
16x6
SG-2
175 CFM
16x6
SG-2
200 CFM
16x6
SG-2
125 CFM
14x6
SG-2
VD
VD
VD
VD
VD
VD
8"‘ S8"‘ S 10x10 S
8
"‘
S
8
"‘
S
FD-B
FD-B
-EF-8 OFF
-AD-1 CLOSED
-TSTAT OPERATION
-INTERMITANT BLOWER OPERATION
1000 CFM RETURN AIR
1000 CFM SUPPLY AIR
UNOCCUPIED MODE
-OCCUPANCY SWITCH STARTS FURNACE
-EF-8 ON
-AD-1 OPEN
-CONTINUOUS BLOWER OPERATION
250 CFM OUTSIDE AIR
750 CFM RETURN AIR
1000 CFM SUPPLY AIR
OCCUPIED MODE
-CU-2 1/2 ON ROOF
F-2 1/2 FURNACE
WC-48"‘ E
WC-610"‘ E
10"‘ E
150 CFM
12x12
SG-6
125 CFM
8"ß NK
SG-1
8"ß NK
RG-1
VD
VD
VD
VD
VD
VD
VD
8
"‘
S
8
"‘
S
8
"‘
S
8
"‘
S
8
"‘
S
20x10 S 20x10 S
20x10 R
VD
OCCUPIED MODE
WITH F-3
INTERLOCK
300 CFM
EF-4
OPERATION
WITH KILN
INTERLOCK
200 CFM
EF-5
12x12
TG-4
2
0
x
1
0
S
2
0
x
1
0
R
2
0
x
1
0
2
0
x
1
0
FD-BF
D
-
B
F
D
-
B
FD-B
FD-B
-EF-4 OFF
-AD-1 CLOSED
-TSTAT OPERATION
-INTERMITANT BLOWER OPERATION
1200 CFM RETURN AIR
1200 CFM SUPPLY AIR
UNOCCUPIED MODE
-OCCUPANCY SWITCH STARTS FURNACE
-EF-4 ON
-AD-1 OPEN
-CONTINUOUS BLOWER OPERATION
300 CFM OUTSIDE AIR
900 CFM RETURN AIR
1200 CFM SUPPLY AIR
OCCUPIED MODE
-CU-3 ROOF
F-3 FURNACE
VD
VD
VD
8"‘ S
VD
RD
RUNS CONTINUOUS
150 CFM
EF-78"‘ E UP
WC-4
TRUSS SPACE
8"‘ E IN
150 CFM
14x6
SG-2
VD
225 CFM
14x8
SG-2
2
0
x
1
0
S
2
0
x
1
0
R
RD
WC-4
TRUSS SPACE
8"‘ E IN
750 CFM
20x20
RG-2
-CONTINUOUS BLOWER OPERATION
200 CFM OUTSIDE AIR
600 CFM RETURN AIR
800 CFM SUPPLY AIR
-CU-2 ON ROOF
F-2 FURNACE
DOWN INSULATE
8x8 OA
INSULATE
10x8 OA
AD-1
INSULATE
14x14 OA UP
24x12 R
DOWN
24x12 R
1
2
x
1
0
S
TRUSS SPACE
8"‘ E IN
VD
VD
VD VD
VD
225 CFM
8"ß NK
SG-1
VD
8
"‘
S
1
2
x
8
S
MATCH LINE MATCH LINE
MATCH LINE
MATCH LINE
DOOR 1"
UNDERCUT
SD
DOOR 1"
UNDERCUT
TOILET
D116
RUNS CONTINUOUS
200 CFM
EF-8
RD
8"‘ E UP
TRUSS SPACE
8"‘ E IN
WC-4
WC-2
TRUSS SPACE
4"‘ E IN
4"‘ E UP
RD
RUNS CONTINUOUS
100 CFM
EF-6
225 CFM
15x15
SG-6
TRASH
8"‘ E IN TRUSS SPACE
WC-4
TRUSS SPACE
8"‘ E IN
DOOR 1"
UNDERCUT
RUNS CONTINUOUS
150 CFM
EF-7
RD
8"‘ E UP
INSULATE
14x14 OA
FSD
DOWN INSULATE
10x8 OA
EACH
200 CFM
8"ß NK
RG-1
MATCH LINE
UP
8"‘ E
10"‘ S
10"‘ S
275 CFM
15x15
SG-6
225 CFM
10"‘ NK
SG-1
10"‘ S 10"‘ S
275 CFM
10"‘ NK
SG-1
4"‘ E IN TRUSS SPACE
2.2 DELUXE B
D113
CORRIDOR
D108
CLOSET
D118
CLOSET
D117
CLOSET
OCCUPIED MODE
WITH F-2 1/2
INTERLOCK
250 CFM
EF-8
FD-B
FD-B
F
D
-
BFD-B
8
"‘
R
24x18
RG-2
200 CFM
14x8
SG-2
200 CFM
14x8
SG-2
200 CFM
14x8
SG-2
150 CFM
12x12
SG-6
175 CFM
12x12
SG-6
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
MI
2
1
7
.
d
g
n
1
0
:
0
2
:
1
8
A
M
8
/
1
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
8
/
1
/
2
0
1
1
MO
D
E
L
:
D
e
f
a
u
l
t
r
j
s
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL
T
T
O
O
T