HomeMy WebLinkAbout008 PI213.pdfREVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
M
w
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
P
I
2
1
3
.
d
g
n
6
:
3
5
:
3
4
P
M
7
/
3
0
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
7
/
3
0
/
2
0
1
1
MO
D
E
L
:
U
n
t
i
t
l
e
d
S
h
e
e
t
j
a
w
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
GENERAL PLUMBING NOTES
STACK OF UNITS. PROVIDE VENTED REGULATOR AND SHUT-OFF AT EACH UNIT.
- GAS TO HVAC UNITS TO BE SUPPLED FROM ABOVE. EXTEND 3/4" (2 PSI) RISER UP TO EACH
TO FREEZING..
- WATER PIPING SHALL NOT BE LOCATED IN EXTERIOR WALLS, ATTIC OR ANY SPACE SUBJECT
IN DROPPED CEILING SPACES.
SPACE WITH APPROPRIATE FIRESTOPPING APPLIED. DUCTWORK TO HAVE SPACE PRIORITY
AS MUCH AS POSSIBLE. WHERE NECESSARY, PENETRATE UP OR DOWN INTO FLOOR TRUSS.
- WATER PIPING SHOWN WITHIN TYPICAL UNITS TO BE LOCATED IN DROPPED CEILING SPACE
- 3 HOUR RATING EXISTS BETWEEN RESIDENTIAL AND GARAGE.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS AND ROOF OR COMMONS.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS.
FOR WALL TYPES AND EXACT LOCATIONS OF RATED CONSTRUCTION.
TO MAINTAIN THE RATING OF THE CONSTRUCTION. REFER TO ARCHITECTURAL PLANS
PIPING (GROUTED TIGHT) OR SEALED WITH A U.L. APPROVED FIRE BARRIER SYSTEM
- ANY PENETRATION OF THE FIRE RATED CONSTRUCTION MUST BE MADE WITH METAL
CEILING SPACES.
JOIST SPACE WHERE POSSIBLE. DUCTWORK TO HAVE SPACE PRIORITY IN DROPPED
- LOCATE ABOVE GRADE DRAIN, VENT AND WATER DISTRIBUTION PIPING WITHIN CEILING
LAYOUTS WITHIN APARTMENT UNITS.
- REFER TO 1/4" TYPICAL UNIT PLUMBING PLANS FOR FIXTURE DESIGNATIONS AND PIPING
1/8" PARTIAL THIRD FLOOR PLUMBING PLAN PI213
TJL/JAW
3507
1.1 DELUXE3505
2.2 GRAND
2.2TRAD.
3503
3501
1.1 DELUXE
3508
2.2 CORNER
3506
1.1.5 DELUXE
1.1.5 DELUXE
3504
3402
2.2 CORNER
DELUXE
1.1.5
3404
DELUXE
1.1.5
3406
2.2 GRAND
3408
2.2 GRAND
3407
3405
STANDARD
2.2
3403
3401
1.1.5 DELUXE
3502
STORAGE
A301
STORAGE
RESIDENT
A304
A303
MECH.
I.T.
A302
A305
CORRIDOR
A306
STORAGE
A307
A308
CORRIDOR
STORAGE
RESIDENT
A311
STORAGE
A310
MECH.
A309
CORRIDOR
STAIR ’B’
STAIR ’A’
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(180 MBH)
@ 2 PSI
3/4" GAS
(288 MBH)
@ 2 PSI
1" GAS
(180 MBH)
@ 2 PSI
3/4" GAS
(390 MBH)
@ 2 PSI
1" GAS
(678 MBH)
@ 2 PSI
1 1/4" GAS
(858 MBH)
@ 2 PSI
1 1/2" GAS (1,038 MBH)
@ 2 PSI
1 1/2" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(1,470 MBH)
@ 2 PSI
2" GAS
(88 MBH)
@ 2 PSI
1/2" GAS
(180 MBH)
@ 2 PSI
3/4" GAS
(268 MBH)
@ 2 PSI
1" GAS
(180 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
2.2 TRAD.
(180 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
UNIT
GUEST
(592 MBH)
@ 2 PSI
1 1/4" GAS
(916 MBH)
@ 2 PSI
1 1/2" GAS
(1,348 MBH)
@ 2 PSI
2" GAS
(396 MBH)
@ 2 PSI
1" GAS
(144 MBH)
@ 2 PSI
3/4" GAS
(2,818 MBH)
@ 2 PSI
2 1/2" GAS
(3,358 MBH)
@ 2 PSI
2 1/2" GAS
PI300
G3
PI300
G4
PI300
G3
G2
PI300 PI300
G2 G2
PI300
PI300
G2
PI300
G3
PI300
G1
PI300
G2
PI300
G8
PI300
G2
PI300
G2
PI300
G1
PI300
G2
G9
PI300
PI300
G1
PI300
G3
PI300
G3
W5
PI400
2" V.
W6
PI400
W7
PI400
2" V.
PI400
W2
W1
PI400
2" V.
3" V.
W7
PI400
TO 4" VTR.
4" V. UP
2" V.
W5
PI400
PI400
W2
W1
PI400
2" V.2" V.
4" V.
W2
PI400
W11
PI400
PI400
W11
2" V.
4" V.
TO 4" VTR.
4" V. UP
W2
PI400
2" V.
W9
PI400
W1
PI401
2" V.
W3
PI400
2" V.
PI400
W6
PI400
W2
2" V.2" V.
W1
PI400
W1
PI400
2" V.2" V.
2" V.2" V.
2" V.3" V.
3" V.
3" V.
4" V.
3" V.
W6
PI400
W4
PI400
2" V.
2" V.3" V.
W3
PI400
PI400
W2
PI400
W6
3" V.
2" V.
W8
PI400
2" V.
3" V.
3" V.
TO 4" VTR.
4" V. UP
W11
PI400
W2
PI400
2" V.
W6
PI400
4" V.3" V.
PI400
W10
2" V.
PI401
W11
PI401
W12
2" V.
3" V.
TO 4" VTR.
4" V. UP
W1
PI400
PI400
W2
PI400
W6
2" V.
2" V.
2" V.3" V.
W3
PI400
W8
PI400
2" V.3" V.
3" V.W2
PI400
PI400
W11
PI400
W11
W6
PI400
2" V.
3" V.
2" V.2" V.
W2
PI401
W3
PI400
W2
PI400 2" V.
W11
PI400 3" V.
W6
PI400
2" V.
W11
PI400
2" V.
3" V.
TO 3" VTR.
3" V. UP
W4
PI400
W6
PI400
PI400
W12
W1
PI400
2" V.
2" V.
W11
PI400
W2
PI400
2" V.
2" V.
2" V.
3" V.
3" V.3" V.
2" V.
TO 4" VTR.
4" V. UP
2" V.
W3
PI400
2" V.
W9
PI400
2" V.
W2
PI400
2" V.
2" V.
3" V.
W1
PI401
2" V.
W3
PI400
2" V.
3" V.
TO 3" VTR.
3" V. UP
PI400
W2
W1
PI400 (1,038 MBH)
@ 2 PSI
1 1/2" GAS
2" V.
3" V.
W5
PI400
W7
PI400
W6
PI400
2" V.
2" V.
TO 3" VTR.
3" V. UP
PI400
W1 PI400
W2
2" V.
3" V.
2" V.
PI400
W12
W1
PI400
2" V.
TO 4" VTR.
4" V. UP
W3
PI400
2" V.
3" V.
3" V.
W8
PI400
W3
PI400
W1
PI400
PI400
W6
PI400
W2
2" V.2" V.
2" V.3" V.3" V.
2" V.
3" V.
MATCH LINE
REFER TO PI221