Loading...
HomeMy WebLinkAbout009 PI218 Addendum 5REV.pdfREVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l In d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l INDEPENDENTINDEPENDENT C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ P I 2 1 8 . d g n 3 : 1 9 : 2 0 P M 4 / 1 6 / 2 0 1 2 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 4 / 9 / 2 0 1 2 MO D E L : U n t i t l e d S h e e t j a w B Y U S E R : A T S C A L E : U S I N G D R I V E R : D R A W I N G L I M I T L I N E 01 AUG 2011 FAX TEL GENERAL PLUMBING NOTES STACK OF UNITS. PROVIDE VENTED REGULATOR AND SHUT-OFF AT EACH UNIT. - GAS TO HVAC UNITS TO BE SUPPLED FROM ABOVE. EXTEND 3/4" (2 PSI) RISER UP TO EACH TO FREEZING.. - WATER PIPING SHALL NOT BE LOCATED IN EXTERIOR WALLS, ATTIC OR ANY SPACE SUBJECT IN DROPPED CEILING SPACES. SPACE WITH APPROPRIATE FIRESTOPPING APPLIED. DUCTWORK TO HAVE SPACE PRIORITY AS MUCH AS POSSIBLE. WHERE NECESSARY, PENETRATE UP OR DOWN INTO FLOOR TRUSS. - WATER PIPING SHOWN WITHIN TYPICAL UNITS TO BE LOCATED IN DROPPED CEILING SPACE - 3 HOUR RATING EXISTS BETWEEN RESIDENTIAL AND GARAGE. - 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS AND ROOF OR COMMONS. - 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS. FOR WALL TYPES AND EXACT LOCATIONS OF RATED CONSTRUCTION. TO MAINTAIN THE RATING OF THE CONSTRUCTION. REFER TO ARCHITECTURAL PLANS PIPING (GROUTED TIGHT) OR SEALED WITH A U.L. APPROVED FIRE BARRIER SYSTEM - ANY PENETRATION OF THE FIRE RATED CONSTRUCTION MUST BE MADE WITH METAL CEILING SPACES. JOIST SPACE WHERE POSSIBLE. DUCTWORK TO HAVE SPACE PRIORITY IN DROPPED - LOCATE ABOVE GRADE DRAIN, VENT AND WATER DISTRIBUTION PIPING WITHIN CEILING LAYOUTS WITHIN APARTMENT UNITS. - REFER TO 1/4" TYPICAL UNIT PLUMBING PLANS FOR FIXTURE DESIGNATIONS AND PIPING W3 W8 W2 W6 W1 FD-1 W7 W6 W5 W2 W6 W4 W8 W3 W1 W1 W3 W6 W8 W2 W1 W3 W8 W3 W8 W3 W1 W1 W1 W3 W2 W4 W1 W1 W5 W6 W7 W1 W6 W2 W3 W8 FD-1 C.O. W2 W1 W2 W6 W9 W1 1/8" PARTIAL FOUNDATION LEVEL PLUMBING PLAN PI218 TJL/JAW PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 PI400 2.2 GRAND 1107 E108 MECH 2.2 DELUXE 1105 STANDARD 2.2 1103 CORNER 2.2 1101 1.1.5 DELUXE 1208 1.1 DELUXE 1209 DELUXE 1.1.5 1106 DELUXE 1.1.5 1104 STANDARD 2.2 1102 STANDARD 2.2 1108 1.1 TRAD. 1110 1.1 TRAD. 1112 CORRIDOR E109 CORNER 2.2 1109 2.2 TRAD. 1111 2.2 DELUXE 1113 2.2 GRAND 1114 PI400 PI400 2" 3" 3" 3" 2" 2" 3" 3" 3" 2" 2" 3" 4" SAN. PI400 PI400 W1 PI400 PI400 W11 PI400 PI400 PI400 PI400 PI400 PI400 PI400 2" 3" 3" 3" 1 1/2" V. 2" 2"2" 3"3"3" PI400 3"3" 2" 2" 3" 3"3"W1 PI400 PI400 2"3" PI400 3"2" 4" SAN.4" SAN.4" SAN. 3" PI401 2" 3" WI400 3" PI400 2"3" 3" 3" 3"3" PI400 2" PI400 3" W2 PI400 6" SAN. C.O. PI400 PI401 2" 2" 3" 2" 3" 2" 3" 2"3" 2" 2" 2" 2" 2" 2" 2" 2" 2" 3" 3" MATCH LINE REFER TO PI219 FD-1 ’E1’ STAIR E105 E106 HSKP IT/ELEC. STORAGE RESIDENTAL E101 E110 STORAGE STORAGE E102 E103 MECH. ’E2’ STAIR 1 1/2" V. UP 2" 3" 2"2" W2 2" 2" 2" W11 W11 W2 PI400 W6 W2 PI400 W6 W2 PI400 W6 PI400 W6 W2 2" 2" W2W6 PI400 W12 W2 PI400 W6 2" W12 W12 2" 2" 2" 2" E107 MECH I.E.=99’-0" C.O. 1 1/2" V. UP 16 APRIL 2012 ADDENDUM #5 REV. 1 1 1 6" SAN.