HomeMy WebLinkAbout010 MI219.pdfMI219 RJS 1/8" THIRD FLOOR HVAC PLAN 200 CFM 8"ß NK SG-1 8"‘ SVD 12x8 S FD-B VENTING UP FURNACE 24x8 DOWN -CONTINUOUS BLOWER OPERATION 150 CFM OUTSIDE AIR 450 CFM RETURN AIR 600 CFM SUPPLY AIR -CU-1 1/2 ON ROOF F-1 1/2 FURNACE 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 VD VD INSULATE TRUSS SPACE 8"‘ OA IN 1 6 x 8 S 1 6 x 8 R 8"‘ S FD-B FD-B RD 8"‘ UP BY HC ACCESS PANEL VD INSULATE TRUSS SPACE 8"‘ OA IN WC-3 FLEX 8"ß ELEV #1 ELEV #2 STAIR ’D’ VENTING UP FURNACE FD-B 8 "‘ S 16x10 S NEAR FLOOR 600 CFM 18x12 RG-2 18 x 1 0 S 1 8 x 1 0 S 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 VD VD 8 "‘ S F D - B FD-B FD-B VDVD 8"‘ S VD RD RUNS CONTINUOUS 150 CFM EF-78"‘ E UP WC-4 TRUSS SPACE 8"‘ E IN 150 CFM 14x6 SG-2 VD 225 CFM 14x8 SG-2 2 0 x 1 0 S 2 0 x 1 0 R -CONTINUOUS BLOWER OPERATION 200 CFM OUTSIDE AIR 600 CFM RETURN AIR 800 CFM SUPPLY AIR -CU-2 ON ROOF F-2 FURNACE DOWN INSULATE 10x8 OA INSULATE 10x8 OA INSULATE 10x8 OA AD-1 24x12 R DOWN 24x12 R 225 CFM 8"ß NK SG-1 VD 8 "‘ S 1 2 x 8 S INSULATE 16x16 OA DOWN INSULATE 18x18 OA UP MATCH LINE MATCH LINE MATCH LINE MATCH LINE -EF-8 OFF -AD-1 CLOSED -TSTAT OPERATION -INTERMITANT BLOWER OPERATION 1000 CFM RETURN AIR 1000 CFM SUPPLY AIR "PRESENT" UNOCCUPIED MODE -OCCUPANCY SWITCH STARTS FURNACE -EF-8 ON -AD-1 OPEN -CONTINUOUS BLOWER OPERATION 250 CFM OUTSIDE AIR 750 CFM RETURN AIR 1000 CFM SUPPLY AIR "FUTURE" OCCUPIED MODE -CU-2 1/2 ON ROOF F-2 1/2 FURNACE I.T. D302 ELECTRICAL D303 D306 STORAGE RESIDENTIAL D304 MECH D305 D307 CARDS CORRIDOR D301 3301 CORNER 2.2 3303 DELUXE 1.1.5 1.1 DELUXE 3305 1.1 TRAD. 3307 C301 CORRIDOR 3309 2.2 DELUXE B 3308 2.2 GRAND 3306 2.2 TRAD. ’C’ STAIR 3304 STANDARD 2.2 3302 GUEST UNIT STANDARD 2.2 3205 2.2 TRAD. 3203 1.1 DELUXE 3201 1.1.5 DELUXE 3204 1.1.5 DELUXE 3202 3207 1.1.5 DELUXE 3206 1.1 DELUXE D309 CORRIDOR LOBBY D310 D311 TRASH SD WC-4 TRASH RUNS CONTINUOUS 150 CFM EF-7 8"‘ E UP RD DOOR 1" UNDERCUT TRUSS SPACE 8"‘ E IN 8"‘ E IN TRUSS SPACE F S D SEE DEATIL "B" SHEET AI606 FOR EXACT LOCATION, 6.3 SQ FT OPEN AREA. 38"W x 56"H LV-2 ( AUTO. LOUVER/DAMPER ) COORDINATE WITH FIRE ALARM CONTRACTOR DETECTION OF SMOKE IN ANY ELEVATOR LOBBY. THE LOUVER/DAMPER SHALL AUTOMATICALLY OPEN UPON THE LOUVER/DAMPER SHALL BE NORMALLY CLOSED. WITH ALL ELEVATOR LOBBY SMOKE DETECTORS. MOTORIZED CLOSING MECHANISM INTERCONNECTED BUILDING CODE SECTION 3004. HOISTWAY VENT PER THE INTERNATIONAL CONNECTION TO ELEVATOR SHAFT PROVIDE 1"x1" W.W. MESH SCREEN AT 38x56 EACH 200 CFM 8"ß NK RG-1 WC-2 WC-4 4"‘ E IN TRUSS SPACE TRUSS SPACE 8"‘ E IN DOOR 1" UNDERCUT RD 4"‘ E UP RUNS CONTINUOUS 100 CFM EF-6 DOOR 1" UNDERCUT 10x10 S VD 150 CFM 14x6 SG-2 8 "‘ S 8"‘ S 200 CFM 16x6 SG-2VD RUNS CONTINUOUS 200 CFM EF-8 8"‘ E UP TRUSS SPACE 4"‘ E IN RD 200 CFM 16x8 SG-2 VD WC-4 TRUSS SPACE 8"‘ E IN VD 225 CFM 10"‘ NK SG-1 10"‘ S 10"‘ S 275 CFM 15x15 SG-6VD 275 CFM 10"‘ NK SG-1 1 2 x 1 0 S 10"‘ S 225 CFM 15x15 SG-6 750 CFM 20x20 RG-2 VD 10"‘ S VD UP 8"‘ E RD OCCUPIED MODE WITH F-2 1/2 INTERLOCK 250 CFM EF-8 TRUSS SPACE 8"‘ E IN D318 CLOSET D308 CLOSET D317 CLOSET D312 TOILET MECH C302 F D - BFD-B REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l INDEPENDENTINDEPENDENT C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ MI 2 1 9 . d g n 1 0 : 0 3 : 1 1 A M 8 / 1 / 2 0 1 1 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 8 / 1 / 2 0 1 1 MO D E L : D e f a u l t r j s B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TELT T T O