HomeMy WebLinkAbout012 PI221 Addendum 5REV.pdfB
B
BBB
B
B
B
B
B
A B
B
B
AB
B
B
A
B
B
B
B
A
B
B
B
A B
B
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
P
I
2
2
1
.
d
g
n
1
0
:
5
7
:
4
6
A
M
4
/
1
1
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
4
/
1
1
/
2
0
1
2
MO
D
E
L
:
U
n
t
i
t
l
e
d
S
h
e
e
t
j
a
w
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
1 1/4" HWR
3" HW, CW
D6
1 1/4" HWR
4" HW & CW
C1
3/4" HWR
1 1/2" CW
1 1/4" HW
C2
1" HWR
1 1/2" HW
2" CW
3/4" HWR
1 1/2" CW
1 1/4" HW
1 1/4" HW, CW
3/4" HWR
3/4" HWR
1 1/2" CW
1 1/4" HW
C3
2" HW, CW
1" HWR
3/4" HWR
1 1/4" CW
1" HW
1 1/4" HW, CW
3/4" HWR
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1" HW
C4
3/4" HWR
1 1/2" CW
1 1/4" HW
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1" HW
2 1/2" CW
2" HW
1" HWR
1 1/4" HW, CW
3/4" HWR
3/4" HWR
1 1/4" CW
1" HW C5
2 1/2" CW
2" HW
1" HWR
D2
3/4" HWR
1 1/2" CW
1 1/4" HW
1 1/4" HW, CW
3/4" HWR
1 1/2" HWR
4" CW
3" HW
3/4" HWR
1 1/4" CW
1" HW
3/4" HWR
1 1/4" CW
1" HW
D3
1 1/2" HWR
4" CW
3" HW
3/4" HWR
1 1/4" CW
1" HW
D4
4" HW, CW
1 1/2" HWR
3/4"
3/4" HWR
1 1/4" CW
1" HW
1 1/4" HW, CW
3/4" HWR
3/4" HWR UP
1 1/4" CW UP
1" HW UP
D5
4" HW, CW
1 1/2" HWR D7
1/2"
1/2" HW, CW DN.
1 1/2" V. UP
3" W. DN.
1.1 DELUXE
1202
1.1 DELUXE
1204
2.2 TRAD.
1203
STANDARD
2.2
1304
2.2 TRAD.
1306
1308
2.2 GRAND
1309
2.2 DELUXE
1.1 TRAD.
1307 1305
1.1 DELUXE
CORNER
2.2
1301DELUXE
1.1.5
1303
STANDARD
2.2
1205
1.1.5 DELUXE
1207
1206
1.1 DELUXE
1302
1.1 TRAD.
GENERAL PLUMBING NOTES
STACK OF UNITS. PROVIDE VENTED REGULATOR AND SHUT-OFF AT EACH UNIT.
- GAS TO HVAC UNITS TO BE SUPPLED FROM ABOVE. EXTEND 3/4" (2 PSI) RISER UP TO EACH
TO FREEZING..
- WATER PIPING SHALL NOT BE LOCATED IN EXTERIOR WALLS, ATTIC OR ANY SPACE SUBJECT
IN DROPPED CEILING SPACES.
SPACE WITH APPROPRIATE FIRESTOPPING APPLIED. DUCTWORK TO HAVE SPACE PRIORITY
AS MUCH AS POSSIBLE. WHERE NECESSARY, PENETRATE UP OR DOWN INTO FLOOR TRUSS.
- WATER PIPING SHOWN WITHIN TYPICAL UNITS TO BE LOCATED IN DROPPED CEILING SPACE
- 3 HOUR RATING EXISTS BETWEEN RESIDENTIAL AND GARAGE.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS AND ROOF OR COMMONS.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS.
FOR WALL TYPES AND EXACT LOCATIONS OF RATED CONSTRUCTION.
TO MAINTAIN THE RATING OF THE CONSTRUCTION. REFER TO ARCHITECTURAL PLANS
PIPING (GROUTED TIGHT) OR SEALED WITH A U.L. APPROVED FIRE BARRIER SYSTEM
- ANY PENETRATION OF THE FIRE RATED CONSTRUCTION MUST BE MADE WITH METAL
CEILING SPACES.
JOIST SPACE WHERE POSSIBLE. DUCTWORK TO HAVE SPACE PRIORITY IN DROPPED
- LOCATE ABOVE GRADE DRAIN, VENT AND WATER DISTRIBUTION PIPING WITHIN CEILING
LAYOUTS WITHIN APARTMENT UNITS.
- REFER TO 1/4" TYPICAL UNIT PLUMBING PLANS FOR FIXTURE DESIGNATIONS AND PIPING
1/8" PARTIAL FIRST FLOOR PLUMBING PLAN PI221
TJL/JAW
S-3
S-4
WC-2
L-4
(2) 1 1/2" HWR
6" HW, CW
MATCH LINE
REFER TO PI220
M
A
T
C
H
L
I
N
E
R
E
F
E
R
T
O
P
C
2
0
3
W10
PI401
W9
PI401
W8
PI401
MATCH LINE
REFER TO PI211
LOBBY
D111
D112
TRASH
TOILET
CRAFTS STUDIO
D109
D115
OFFICE
D114
STORAGE
OUTDOOR
D110
KILN
D113
CORRIDOR
TV ROOM
D107
C101
CORRIDOR
D101
CORRIDOR
D105
MECH
STORAGE
RESIDENT
D106 D104
TRASH
ELECTRICAL
D103
I.T.
D102
STAIR ’D’
ELEV #2
ELEV #1
4" GAS UP (9,226 MBH)
1 1/2" GAS DN. (1,250 MBH)
1 1/4" CW DN.
(10,226 MBH)
@ 2" PSI
4 GAS
1 1/4" CW
D116
3/4" CW DN.
1/2" HW DN.
1/2" HW, CW DN.
3/4" HW, CW UP
C102
MECH
1 1/2" V. UP
1 1/2" V.
1 1/4" HWR UP
3" HW, CW UP
1 1/4" HWR UP
3" HW, CW UP
STAIR ’C’
HB-1
3/4"
HB-1
3/4"
HB-1
3/4"
HB-1
3/4"
1
1
16 APRIL 2012
ADDENDUM #5 REV.
2
2
17 FEB 2012
ADDENDUM #5