HomeMy WebLinkAbout015 EI225 Addendum 5REV.pdfEI225
TJL/TAR
1/8" SECOND FLOOR POWER & SYSTEMS PLAN
RESIDENT APARTMENT SMOKE DETECTOR - ALTERNATE #1
LOCATED IN THE UNIT BATHROOM
- ACCESSABLE UNITS TO HAVE AN ADDITIONAL AUDIO/VISUAL FIRE ALARM
BEDROOMS AND LIVING SPACE
- ACCESSABLE UNITS TO HAVE AUDIO / VISUAL FIRE ALARMS AT
AT BEDROOMS AND LIVING SPACE
- APARTMENT UNITS TO BE EQUIPPED W/ SYSTEM MINI HORN FIRE ALARMS
SOUND A GENERAL ALARM AND AUTO-DIAL THE FIRE DEPARTMENT.
ASSESS THE EVENT. PAST THE DELAY TIME PERIOD THE SYSTEM WILL
DETERMINED BY THE OWNER / OPERATOR TO ALLOW FOR STAFF TO
PAGER SYSTEM AND DELAY GENERAL ALARM BY A TIME PERIOD TO BE
- MODULE TO BE PROGAMMED TO LOCALLY ANNUNCIATE EVENT TO STAFF
FIRE ALARM SYSTEM MONITOR MODULE.
- SMOKE DETECTOR WITH TYPE ’C’ CONTACTS TO BE CONNECTED TO
- (1) SMOKE DETECTOR TO HAVE TYPE ’C’ AUXILLIARY CONTACTS
WITH BATTERY BACK-UP. SMOKE DETECTORS TO BE INTERCONNECTED
- UNIT SMOKE DETECTORS TO BE STAND ALONE TYPE, LINE VOLTAGE
DETECTOR AND THE BUILDING FIRE ALARM SYSTEM
NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE
DETECTOR AND THE BUILDING FIRE ALARM SYSTEM
NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE
T T
T
T
T
TT
T
T
T
T
T
T
T
T
T
V
V
V
E
H
D
A
B
KEYED NOTES THIS SHEET ONLY
L
M
N
P
R
C
- CABLE TV
- TELEPHONE
(4) 4" CONDUITS AT FLOOR
120V - 1‘ - 20AMP - 1P CIRCUIT (RDA-2)
-W/ (2) 4-PLEX RECEPTACLES
WHITE AND BOLTED TO WALL TO 8’ A.F.F.
3/4" PLYWOOD PANEL PAINTED
TELEPHONE/CABLE EQUIPMENT PANELS
F
20 AMP - 1P CIRCUIT (RDC-9)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-2 1/2 (SO-97)
G
J
K
20 AMP - 1P CIRCUIT (RDA-15)
120V - 1‘ - MCA = 2.1 AMP
EXHAUST FAN EF-8 (SO-100)
20 AMP - 1P CIRCUIT (RDA-15)
120V - 1‘ - MCA = 2.1 AMP
EXHAUST FAN EF-8 (SO-102)
20 AMP - 1P CIRCUIT (RDA-15)
120V - 1‘ - MCA = 1.3 AMP
EXHAUST FAN EF-7 (SO-103)
S
20 AMP - 2P CIRCUIT (RDA-21,23)
208V - 1‘ - 1500 WATTS
W/ BUILT-IN THERMOSTAT
ELECTRIC BASEBOARD - BB-6
ELECTRICAL INSTALLATION)
ERS PROVIDER PRIOR TO START OF
(VERIFY QUANTITY AND LOCATION W/
20AMP - 1P CIRCUIT (RDC-34)
120V - 1‘ - 200W
RECEIVER/TRANSMITTER
RESPONSE CALL SYSTEM (ERS)
@7’ A.F.F. FOR WIRELESS EMERGENCY
(2) DUPLEX RECEPTACLES W/10"x10" J-BOX
20 AMP - 1P CIRCUIT (RDA-15)
120V - 1‘ - MCA = 2.6 AMP
EXHAUST FAN EF-7 (SO-104)
PAGER SYSTEM
ALARM ANNUNCIATOR PANELS AND STAFF
FIRE ALARM SYSTEM AND ANNUNCIATE AT
CO DETECTOR TO BE CONNECTED TO
INSTALLED BY FIRE ALARM CONTRACTOR -
CARBON MONOXIDE DETECTOR PROVIDED AND
T
V
DETECTOR MAY BE USED
COMBINATION SMOKE DETECTOR / CO
PAGER SYSTEM
ALARM ANNUNCIATOR PANELS AND STAFF
INDIVIDUAL APARTMENT UNIT AND AT
FIRE ALARM SYSTEM AND ANNUNCIATE AT
CO DETECTOR TO BE CONNECTED TO
INSTALLED BY FIRE ALARM CONTRACTOR -
CARBON MONOXIDE DETECTOR PROVIDED AND
1.1.5 DELUXE
2202
2204
1.1.5 DELUXE
1.1 DELUXE
2201
2302
1.1 TRAD.
2304
STANDARD
2.2
2306
2.2 TRAD.
2.2 GRAND
2308
CORRIDOR
C201
2.2 TRAD.
2203
2309
2.2 DELUXE B
1.1 TRAD.1.1 DELUXE
23052307 2303
DELUXE
1.1.5
2301
2206
1.1 DELUXE
2207
1.1.5 DELUXE
2205
STANDARD
2.2
MECH
C202
I.T.
D202
ELECTRICAL
D203
D204
MECH
D205
D207
CARDS
D211
TRASH
LOBBY
D210
CORRIDOR
D209
CORRIDOR
D201
20 AMP - 1P CIRCUIT (RDA-20)
120V - 1‘ - 350 WATTS
SEE ARCHITECTURAL ELEV. FOR MOUNTING HT.
BY OWNER - VERIFY MOUNTING, POWER ETC.
WALL MOUNT FLAT PANEL TV UNIT PROVIDED
A
D
BC
20AMP - 1P CIRCUITS (RDA-7)
120V - 1‘ - 100 WATTS
VERIFY W/ F.A. CONTRACTOR
FIRE ALARM NAC PANEL (SO-96)
E F
G
GFI GFI
GFI
GFI
20 AMP - 1P CIRCUIT (RDC-11)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-2 (SO-98)
20 AMP - 1P CIRCUIT (RDC-17)
120V - 1‘ - MCA = 11.0 AMPS
FURNACE F-1 1/2 (SO-99)
H
L
K
M
N
15AMP - 1P CIRCUIT (RDA-13)
120V - 1‘ - 0.5 AMPS
MOTORIZED SMOKE DAMPER
R
R
STORAGE
RESIDENT
D206
P
PER INDIANA ADMINISTRATIVE CODE
INTERCONNECTED WITH FIRE ALARM SYSTEM
TO INITIATE FIRE FIGHTER SERVICE AND
ELEVATOR CONTROLLER. SMOKE DETECTOR
SMOKE DETECTOR INTERCONNECTED WITH
(RDA-74)
(RDA-74)
(RDA-76)
(RDA-76)
(RDA-76)
(RDA-76)
(RDA-72)(RDA-72)(RDA-70)(RDA-70)
(RDA-70)
(RDA-22)
(RDA-10)
(RDA-10)
(RDA-10)
(RDA-10)
(RDA-10)
(RDA-8)
(RDA-6)
(RDA-6)
(RDA-6)
(RDA-6)
(RDA-6)
(RDA-6)
(RDA-8)
(RDA-8)
(RDA-8)
(RDA-8)
(RDA-8)
20 AMP - 1P CIRCUIT (RDA-15)
120V - 1‘ - MCA = 1.1 AMP
EXHAUST FAN EF-6 (SO-101)
J
GFI
CORNER B
2.2
TRASH
TOILET
D212
1
1
1
1
1
1
1 16 APRIL 2012
ADDENDUM #5 REV.
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
INDEPENDENTINDEPENDENT
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
E
I
2
2
5
.
d
g
n
1
1
:
0
5
:
3
1
A
M
4
/
1
3
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
4
/
1
3
/
2
0
1
2
MO
D
E
L
:
D
e
f
a
u
l
t
t
a
r
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL
S
M
M
S
F
F
S
S
S
S
S
S
F VAFVAFVA
F VA
FVA
FVA
FVA
FVA
FVA
F VA
F VA
MM
MM
MM
FM
S
S
F M
C
S
F M
FM
S
SS
C
S C
S F M
MM
S
F M
S
F M
C
S
MM MM
MM
MM
MM
C
F M
S
F M
S
S
FM
F M
S
S
S
C
SC
SFM
F M C S
S
F M
FM
SC
S
S
MM
S
C
S
F M
MM
MM
F M
F M
S
C
S
S
F M
S
C
F M
S
S
MM
S
S
C
S
F M
F M
MM
S
C
F M
F M
S
S
MM
S
C
F M
F M
S
S
4
4
S
S
T F
C
C
C
TV
T
MM
C
S
S F M
F VA
FVA
F VA
S S S S S S S