Loading...
HomeMy WebLinkAbout015 EI225 Addendum 5REV.pdfEI225 TJL/TAR 1/8" SECOND FLOOR POWER & SYSTEMS PLAN RESIDENT APARTMENT SMOKE DETECTOR - ALTERNATE #1 LOCATED IN THE UNIT BATHROOM - ACCESSABLE UNITS TO HAVE AN ADDITIONAL AUDIO/VISUAL FIRE ALARM BEDROOMS AND LIVING SPACE - ACCESSABLE UNITS TO HAVE AUDIO / VISUAL FIRE ALARMS AT AT BEDROOMS AND LIVING SPACE - APARTMENT UNITS TO BE EQUIPPED W/ SYSTEM MINI HORN FIRE ALARMS SOUND A GENERAL ALARM AND AUTO-DIAL THE FIRE DEPARTMENT. ASSESS THE EVENT. PAST THE DELAY TIME PERIOD THE SYSTEM WILL DETERMINED BY THE OWNER / OPERATOR TO ALLOW FOR STAFF TO PAGER SYSTEM AND DELAY GENERAL ALARM BY A TIME PERIOD TO BE - MODULE TO BE PROGAMMED TO LOCALLY ANNUNCIATE EVENT TO STAFF FIRE ALARM SYSTEM MONITOR MODULE. - SMOKE DETECTOR WITH TYPE ’C’ CONTACTS TO BE CONNECTED TO - (1) SMOKE DETECTOR TO HAVE TYPE ’C’ AUXILLIARY CONTACTS WITH BATTERY BACK-UP. SMOKE DETECTORS TO BE INTERCONNECTED - UNIT SMOKE DETECTORS TO BE STAND ALONE TYPE, LINE VOLTAGE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE T T T T T TT T T T T T T T T T V V V E H D A B KEYED NOTES THIS SHEET ONLY L M N P R C - CABLE TV - TELEPHONE (4) 4" CONDUITS AT FLOOR 120V - 1‘ - 20AMP - 1P CIRCUIT (RDA-2) -W/ (2) 4-PLEX RECEPTACLES WHITE AND BOLTED TO WALL TO 8’ A.F.F. 3/4" PLYWOOD PANEL PAINTED TELEPHONE/CABLE EQUIPMENT PANELS F 20 AMP - 1P CIRCUIT (RDC-9) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-2 1/2 (SO-97) G J K 20 AMP - 1P CIRCUIT (RDA-15) 120V - 1‘ - MCA = 2.1 AMP EXHAUST FAN EF-8 (SO-100) 20 AMP - 1P CIRCUIT (RDA-15) 120V - 1‘ - MCA = 2.1 AMP EXHAUST FAN EF-8 (SO-102) 20 AMP - 1P CIRCUIT (RDA-15) 120V - 1‘ - MCA = 1.3 AMP EXHAUST FAN EF-7 (SO-103) S 20 AMP - 2P CIRCUIT (RDA-21,23) 208V - 1‘ - 1500 WATTS W/ BUILT-IN THERMOSTAT ELECTRIC BASEBOARD - BB-6 ELECTRICAL INSTALLATION) ERS PROVIDER PRIOR TO START OF (VERIFY QUANTITY AND LOCATION W/ 20AMP - 1P CIRCUIT (RDC-34) 120V - 1‘ - 200W RECEIVER/TRANSMITTER RESPONSE CALL SYSTEM (ERS) @7’ A.F.F. FOR WIRELESS EMERGENCY (2) DUPLEX RECEPTACLES W/10"x10" J-BOX 20 AMP - 1P CIRCUIT (RDA-15) 120V - 1‘ - MCA = 2.6 AMP EXHAUST FAN EF-7 (SO-104) PAGER SYSTEM ALARM ANNUNCIATOR PANELS AND STAFF FIRE ALARM SYSTEM AND ANNUNCIATE AT CO DETECTOR TO BE CONNECTED TO INSTALLED BY FIRE ALARM CONTRACTOR - CARBON MONOXIDE DETECTOR PROVIDED AND T V DETECTOR MAY BE USED COMBINATION SMOKE DETECTOR / CO PAGER SYSTEM ALARM ANNUNCIATOR PANELS AND STAFF INDIVIDUAL APARTMENT UNIT AND AT FIRE ALARM SYSTEM AND ANNUNCIATE AT CO DETECTOR TO BE CONNECTED TO INSTALLED BY FIRE ALARM CONTRACTOR - CARBON MONOXIDE DETECTOR PROVIDED AND 1.1.5 DELUXE 2202 2204 1.1.5 DELUXE 1.1 DELUXE 2201 2302 1.1 TRAD. 2304 STANDARD 2.2 2306 2.2 TRAD. 2.2 GRAND 2308 CORRIDOR C201 2.2 TRAD. 2203 2309 2.2 DELUXE B 1.1 TRAD.1.1 DELUXE 23052307 2303 DELUXE 1.1.5 2301 2206 1.1 DELUXE 2207 1.1.5 DELUXE 2205 STANDARD 2.2 MECH C202 I.T. D202 ELECTRICAL D203 D204 MECH D205 D207 CARDS D211 TRASH LOBBY D210 CORRIDOR D209 CORRIDOR D201 20 AMP - 1P CIRCUIT (RDA-20) 120V - 1‘ - 350 WATTS SEE ARCHITECTURAL ELEV. FOR MOUNTING HT. BY OWNER - VERIFY MOUNTING, POWER ETC. WALL MOUNT FLAT PANEL TV UNIT PROVIDED A D BC 20AMP - 1P CIRCUITS (RDA-7) 120V - 1‘ - 100 WATTS VERIFY W/ F.A. CONTRACTOR FIRE ALARM NAC PANEL (SO-96) E F G GFI GFI GFI GFI 20 AMP - 1P CIRCUIT (RDC-11) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-2 (SO-98) 20 AMP - 1P CIRCUIT (RDC-17) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-1 1/2 (SO-99) H L K M N 15AMP - 1P CIRCUIT (RDA-13) 120V - 1‘ - 0.5 AMPS MOTORIZED SMOKE DAMPER R R STORAGE RESIDENT D206 P PER INDIANA ADMINISTRATIVE CODE INTERCONNECTED WITH FIRE ALARM SYSTEM TO INITIATE FIRE FIGHTER SERVICE AND ELEVATOR CONTROLLER. SMOKE DETECTOR SMOKE DETECTOR INTERCONNECTED WITH (RDA-74) (RDA-74) (RDA-76) (RDA-76) (RDA-76) (RDA-76) (RDA-72)(RDA-72)(RDA-70)(RDA-70) (RDA-70) (RDA-22) (RDA-10) (RDA-10) (RDA-10) (RDA-10) (RDA-10) (RDA-8) (RDA-6) (RDA-6) (RDA-6) (RDA-6) (RDA-6) (RDA-6) (RDA-8) (RDA-8) (RDA-8) (RDA-8) (RDA-8) 20 AMP - 1P CIRCUIT (RDA-15) 120V - 1‘ - MCA = 1.1 AMP EXHAUST FAN EF-6 (SO-101) J GFI CORNER B 2.2 TRASH TOILET D212 1 1 1 1 1 1 1 16 APRIL 2012 ADDENDUM #5 REV. REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l In d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l INDEPENDENTINDEPENDENT C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ E I 2 2 5 . d g n 1 1 : 0 5 : 3 1 A M 4 / 1 3 / 2 0 1 2 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 4 / 1 3 / 2 0 1 2 MO D E L : D e f a u l t t a r B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL S M M S F F S S S S S S F VAFVAFVA F VA FVA FVA FVA FVA FVA F VA F VA MM MM MM FM S S F M C S F M FM S SS C S C S F M MM S F M S F M C S MM MM MM MM MM C F M S F M S S FM F M S S S C SC SFM F M C S S F M FM SC S S MM S C S F M MM MM F M F M S C S S F M S C F M S S MM S S C S F M F M MM S C F M F M S S MM S C F M F M S S 4 4 S S T F C C C TV T MM C S S F M F VA FVA F VA S S S S S S S