HomeMy WebLinkAbout016 MI300.pdfAREA = 856 SQFT
MI300
RJS
1/4" UNIT HVAC PLANS
HC ( MAGIC PAK UNIT ) MOUNTING DETAIL
3/4" PLYWOOD
OUTSIDE WALL FRAMING
SLEEVE & THRU WALL UNIT
CAULK PERIMETER BETWEEN
FOOTPRINT OF UNIT
- PLATFORM TO BE UNDER ENTIRE
PER MANUFACRUERS RECOMMENDATIONS.
- CONSTRUCT HAVC UNIT PLATFORM
NOTES
NO SCALE
CLOSET WITH A HC ( MAGIC PAK UNIT )
SECTION THROUGH A TYPICAL HVAC
NO SCALE
T
1’-0"
NOTES:
LIP PER EXHIBIT 410.1 OF NEC 2005
FROM SHOWER AND/OR BATHTUB
MAINTAIN MIN 3’-0" CLEARANCE
FOR LOCATION OF EXHAUST FANS,
NOTES:
LIP PER EXHIBIT 410.1 OF NEC 2005
FROM SHOWER AND/OR BATHTUB
MAINTAIN MIN 3’-0" CLEARANCE
FOR LOCATION OF EXHAUST FANS,
NO SCALE
HC (MAGIC PAK UNIT) CONDENSATE DRAIN
THIRD FLOOR
SECOND FLOOR
FIRST FLOOR
PAK UNIT
MAGIC
HC
PAK UNIT
MAGIC
HC
PAK UNIT
MAGIC
HC
OPEN
"
3/4" BRANCH
TYPICAL 1 "
PARKING LEVEL
GRADE
200 CFM
16x6
SG-5
200 CFM
16x6
SG-5
600 CFM RET
600 CFM SUP
HC-1
400 CFM
14x18
RG-3
NEAR FLOOR
200 CFM
14x8
RG-314x8 R
(IN ADDITION TO DUCT LINING) IN HVAC CLOSET
EXTERNALLY INSULATE ALL DUCTWORK
INSULATE
14x6 DOWN
DUCT LINER
WITH 1/2"
14x10 O.D.
DUCT LINER
WITH 1/2"
14x10 O.D.
ROOF
ATTIC
75 CFM
HF-1
4" ‘ E
WC-1WC-2
OUTSIDE WALL
PITCH TOWARDS
4" ‘ E IN TRUSS SPACE
AREA = 766 SQFT
12x8 S 8x8 S
100 CFM
10x6
SG-5
100 CFM
10x6
SG-5
200 CFM
16x6
SG-5
200 CFM
16x6
SG-5
600 CFM RET
600 CFM SUP
HC-1
400 CFM
14x18
RG-3
NEAR FLOOR
200 CFM
14x8
RG-3
(IN ADDITION TO DUCT LINING) IN HVAC CLOSET
EXTERNALLY INSULATE ALL DUCTWORK
DUCT LINER
WITH 1/2"
12x10 O.D.
DUCT LINER
WITH 1/2"
14x10 O.D.
75 CFM
HF-1
4" ‘ E
WC-1WC-2
OUTSIDE WALL
PITCH TOWARDS
4" ‘ E IN TRUSS SPACE
8x8 S
100 CFM
10x6
SG-5
100 CFM
10x6
SG-5
T
1’-0"
INSULATE
14x6
INSULATE
14x6 DOWN
ON GRADE
1 1/4" SPILL
DETAIL - INDEPENDANT LIVING
TO MEET ARCHITECTURAL DESIGN.
THE CORRECT HEIGHT OF PLATFORM
CONTRACTOR NEED TO CORDINATE
ROUGH CARPENTER & HVAC
NOTE
CONNECTION
CONTRACTOR
BEYOND BY HVAC
CONDENSATE RISER
3/4" CONDENSATE
EXTERIOR
BUILDING
SLEEVE
MAGIC PAK
MAGIC PAC UNIT
HC THRU-WALL UNIT
PAK UNIT
MAGIC
HC
C
C
C
C
SECTIONS.
ON ARCHITECTURAL
TO BE AS INDICATED
HEIGHT OF PLATFORM
SOFFIT
RETURN DUCT
SUPPLY OR RETURN DUCT
SUPPLY DUCT
WC-2
TYPICAL
DUCT LINER
WITH 1/2
16x12 OD
TYPICAL
FLEX CONN
ANSI TYPE ’A’ UNIT 1507 SIMILAR
MT102
3
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ E UP ON
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ DRYER VENT UP ON
MT102
3
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ E UP ON
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ DRYER VENT UP ON
SEE DETAIL THIS SHEET
PLYWOOD BY OTHERS
WOOD STUDS &
WOOD STUDS
TO MINIMIZE WIDTH OF SOFFIT
TO EXTERIOR WALL AS POSSIBLE
INSTALL DUCTWORK AS CLOSE
NOTE
TO MINIMIZE WIDTH OF SOFFIT
TO EXTERIOR WALL AS POSSIBLE
INSTALL DUCTWORK AS CLOSE
NOTE
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
MI
3
0
0
.
d
g
n
1
0
:
0
5
:
3
3
A
M
8
/
1
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
4
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
8
/
1
/
2
0
1
1
MO
D
E
L
:
P
l
o
t
S
h
e
e
t
r
j
s
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
1.1 TRADITIONAL 1.1 DELUXE
LIVING ROOM
LIVING ROOM
BEDROOM
BEDROOM
W.I.C.W.I.C.
ENTRY
ENTRY
KITCHENKITCHEN
SHOWER
SHOWER
PATIO
PATIO