HomeMy WebLinkAbout017 MI301.pdfMI301 RJS 1/4" UNIT HVAC PLANS NOTES: LIP PER EXHIBIT 410.1 OF NEC 2005 FROM SHOWER AND/OR BATHTUB MAINTAIN MIN 3’-0" CLEARANCE FOR LOCATION OF EXHAUST FANS, 8x8 S10x8 S 175 CFM 14x6 SG-5 200 CFM 16x6 SG-5 NEAR FLOOR 175 CFM 14x8 RG-3 T 1’-0" 14x6 75 CFM 12x6 SG-5 75 CFM HF-1 NOTES: LIP PER EXHIBIT 410.1 OF NEC 2005 FROM SHOWER AND/OR BATHTUB MAINTAIN MIN 3’-0" CLEARANCE FOR LOCATION OF EXHAUST FANS, 4" ‘ E 75 CFM HF-1 4" ‘ E WC-2WC-1 WC-2 MT102 3 (IN ADDITION TO DUCT LINING) IN HVAC CLOSET EXTERNALLY INSULATE ALL DUCTWORK OUTSIDE WALL PITCH TOWARDS 4" ‘ E IN TRUSS SPACE 4" ‘ E IN TRUSS SPACE NEAR CEILING 14x6 RG-3 AREA = 969 SQFT 100 CFM 12x6 SG-5 DUCT LINER WITH 1/2" 16x10 O.D. 800 CFM RET 800 CFM SUP HC-2 INSULATE 14x6 DOWN DUCT LINER WITH" 16x10 O.D. 250 CFM 18x6 SG-5 14x10 R 12x8 S AREA = 1075 SQFT 75 CFM HF-1 4" ‘ E WC-2 OUTSIDE WALL PITCH TOWARDS 4" ‘ E IN TRUSS SPACE WC-2 WC-1 MT102 3 75 CFM HF-1 4" ‘ E OUTSIDE WALL PITCH TOWARDS 4" ‘ E IN TRUSS SPACE NEAR CEILING 14x6 RG-3 14x6 NEAR CEILING 14x6 RG-3 OUTSIDE WALL PITCH TOWARDS 4" ‘ E IN TRUSS SPACE 200 CFM 16x6 SG-5 NEAR FLOOR 175 CFM 14x8 RG-3 (IN ADDITION TO DUCT LINING) IN HVAC CLOSET EXTERNALLY INSULATE ALL DUCTWORK 800 CFM RET 800 CFM SUP HC-2 INSULATE 14x6 DOWN DUCT LINER WITH" 16x10 O.D. 250 CFM 18x6 SG-5 75 CFM 12x6 SG-5 75 CFM 12x6 SG-5 100 CFM 12x6 SG-5 100 CFM 12x6 SG-5 8x8 S 8x8 S 8 x 8 S 8 x 8 S 1 2 x 6 S 14x6 INSULATE T 1’-0" IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ DRYER VENT UP ON IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ DRYER VENT UP ON IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ E UP ON IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ E UP ON IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ E UP ON 625 CFM 24x14 RG-3 625 CFM 24x14 RG-3 NEAR CEILING 14x6 RG-3 TO MINIMIZE WIDTH OF SOFFIT. TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE TO MINIMIZE WIDTH OF SOFFIT. TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE TO MINIMIZE WIDTH OF SOFFIT TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE TO MINIMIZE WIDTH OF SOFFIT. TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ MI 3 0 1 . d g n 1 0 : 0 6 : 0 4 A M 8 / 1 / 2 0 1 1 P L O T T E D O N : 4 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 8 / 1 / 2 0 1 1 MO D E L : P l o t S h e e t r j s B Y U S E R : A T S C A L E : U S I N G D R I V E R : D R A W I N G L I M I T L I N E 01 AUG 2011 FAX TEL 2.2 STANDARD W.I.C. BEDROOM LIVING ROOM SHOWER KITCHENBATH BEDROOM ENTRY KITCHEN W.I.C. SHOWER TOILET LIVING ROOM PATIO DEN BEDROOM 1.1.5 DELUXE ENTRY PATIO RETURN VALANCES TO WALL (TYPICAL OF ALL). SEE SHEET AT401 FOR TRIM PROFILES. PROVIDE BASE BEHIND REFRIGERATOR AND RANGE. TO FLOOR, CEILING & WALL. ALL COUNTERTOPS, SPLASHES & CABINETS TO BE SCRIBED FIXTURES AND FLOOR/WALL UNLESS OTHERWISE NOTED. PROVIDE SILICONE SEALANT BETWEEN ALL PLUMBING ENDS INCLUDING NEXT TO APPLIANCES. PROVIDE FINISHED END PANELS @ ALL EXPOSED CABINET PROVIDE 2 x 6 BLOCKING FOR ALL GRAB BARS. DIMENSIONS. FIELD VERIFY ALL TOPS, MIRRORS AND CABINETRY RECOMMENDED BY MANUFACTURER FOR ADA COMPLIANCE. MOUNT ALL WASHROOM ACCESSORIES AT HEIGHTS AS INTERIOR ELEVATION NOTES: