HomeMy WebLinkAbout020 MI304.pdfMI304
RJS
1/4" UNIT HVAC PLANS
1000 CFM RET
1000 CFM SUP
HC-2 1/2
T
75 CFM
12x6
SG-5
100 CFM
12x6
SG-58x8 S
8
x
8
S
HVAC CLOSET
(IN ADDITION TO DUCT LINING) IN
EXTERNALLY INSULATE ALL DUCTWORK
14
x
6
NEAR CEILING
14x6
RG-3
NEAR CEILING
14x6
RG-3
14x6
500 CFM
24x12
RG-3
500 CFM
24x12
RG-3
8x8 S
175 CFM
16x6
SG-5
12x8 S 16x8 S
1
2
x
8
S
8
x
8
S
150 CFM
14x6
SG-5
125 CFM
14x6
SG-5
1
0
x
8
S
100 CFM
12x6
SG-5
100 CFM
12x6
SG-5
100 CFM
12x6
SG-5
75 CFM
12x6
SG-5
75 CFM
HF-1
WC-2
OUTSIDE WALL
PITCH TOWARDS
4" ‘ E IN TRUSS SPACE
4" ‘ E IN TRUSS SPACE
NOTES:
LIP PER EXHIBIT 410.1 OF NEC 2005
FROM SHOWER AND/OR BATHTUB
MAINTAIN MIN 3’-0" CLEARANCE
FOR LOCATION OF EXHAUST FANS,
NOTES:
LIP PER EXHIBIT 410.1 OF NEC 2005
FROM SHOWER AND/OR BATHTUB
MAINTAIN MIN 3’-0" CLEARANCE
FOR LOCATION OF EXHAUST FANS,
AREA = 1379 SQFTAREA = 688 SQFT
75 CFM
HF-1
4" ‘ E
WC-2
OUTSIDE WALL
PITCH TOWARDS
4" ‘ E IN TRUSS SPACE
4" ‘ E IN TRUSS SPACE
WC-1
MT102
3
DUCT LINER
WITH 1/2"
18x8 O.D.
DUCT LINER
WITH 1/2"
18x10 O.D.
DUCT LINER
WITH 1/2"
18x10 O.D.
75 CFM
HF-1
4" ‘ E
WC-2
OUTSIDE WALL
PITCH TOWARDS
4" ‘ E IN TRUSS SPACE
T
1’-0"
200 CFM
16x6
SG-5
200 CFM
16x6
SG-5
600 CFM RET
600 CFM SUP
HC-1
(IN ADDITION TO DUCT LINING) IN HVAC CLOSET
EXTERNALLY INSULATE ALL DUCTWORK
DUCT LINER
WITH 1/2"
14x10 O.D.
8x8 S
100 CFM
10x6
SG-5
100 CFM
10x6
SG-5
8x8 S
DUCT LINER
WITH 1/2"
10x10 O.D.
DUCT LINER
WITH 1/2"
8x8 O.D.
600 CFM
24x14
RG-3
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ E UP ON
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ DRYER VENT UP ON
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ E UP ON
IN 2ND FLOOR JOIST SPACE
3RD FLOOR DUCT RUNS
4"‘ DOWN FROM 3RD FLOOR.
1ST & 2ND FLOORS.
4" ‘ E UP ON
NEAR CEILING
14x6
RG-3
NEAR CEILING
14x6
RG-3
OUTSIDE WALL
PITCH TOWARDS
4" ‘ E IN TRUSS SPACE
TO MINIMIZE WIDTH OF SOFFIT
TO EXTERIOR WALL AS POSSIBLE
INSTALL DUCTWORK AS CLOSE
NOTE
TO MINIMIZE WIDTH OF SOFFIT
TO EXTERIOR WALL AS POSSIBLE
INSTALL DUCTWORK AS CLOSE
NOTE
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
MI
3
0
4
.
d
g
n
1
0
:
0
7
:
0
9
A
M
8
/
1
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
4
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
8
/
1
/
2
0
1
1
MO
D
E
L
:
P
l
o
t
S
h
e
e
t
r
j
s
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
2.2 GRAND
BEDROOM
PATIO
ENTRY
SHOWER
W.I.C.
BATH
BEDROOM
LIVING ROOM
KITCHEN
DINING
GUEST UNIT
BALCONY
LIVING ROOM
SHOWER
ENTRY