HomeMy WebLinkAbout020 PI303.pdfB WC-1
L-1
BT-1
WOB-1
WC-1
L-1
SH-1
S-1
2" WET V. DN.
1 1/2" V. UP
UNIT SHUT-OFF VALVESRISER SHUT-OFF VALVES
BALANCING VALVE
3/4" HWR
2" WET V. DN.
1 1/2" V. UP
B
S-1 WOB-1
L-1
WC-1
BT-1
SH-1
WC-1
L-1
UNIT WATER ISOMETRIC W1
PI303
ICE MAKER
DISHWASHER
2" W. DN. IN WALL
STOP @ 48" A.F.F.
PROVIDE ANGLE
STOP @ 48" A.F.F.
PROVIDE ANGLE
1 1/4" HW, 1 1/2" CW
1 1/4" HW, CW UP
DROPPED CEILING SPACE
HW, CW MANIFOLDS IN
4" S.S. UP
BALANCING VALVE
3/4" HWR
1 1/4" HW, 1 1/2" CW
DROPPED CEILING SPACE
HW, CW MANIFOLDS IN
1 1/4" HW, CW
1" HW, CW
TO UNIT SHOWN BELOW.
PIPING IS SIMILAR
FLOOR APARTMENT
SECOND THRU THIRD
1 1/2" V. UP
3" W.S. DN.
1 1/2" V. UP
2" W.S. DN.
1 1/2" V. UP
2" W.S. DN.
4" S.S. UP
1 1/2" V. UP
2" W.S. DN.
PI303
TJL/JAW
BATH
ENTRY
SHOWER
BEDROOM
PATIO
LIVING ROOM
BEDROOM
KITCHEN
PATIO
W.I.C.
GENERAL PLUMBING NOTES
- PROVIDE COPPER STUB-OUT AT ALL FIXTURE CONNECTIONS.
RECOMMENDATIONS
- ALL TUBING TO BE BENT AND SUPPORTED IN ACCORDANCE TO TUBING MANUFACTURER’S
MAY BE LOCATED IN ATTIC OR OTHER UNHEATED SPACE.
- MANIFOLDS TO BE LOCATED IN DROPPED CEILING SPACE. NO PIPING OR MANIFOLDS
- LABEL EACH FIXTURE RUN-OUTS AT MANIFOLD.
- CAP ALL UNUSED MANIFOLD PORTS.
- ALL FIXTURE RUN-OUTS TO BE 1/2" TUBING.
MAINS, RISER AND BRANCH LINES INTO APARTMENT SHALL BE RIGID PIPE.
- SYSTEM SHOWN EMPLOYS MANIFOLDED PEX TUBING WITHIN THE APARTMENTS. WATER
WATER DISTRIBUTION NOTES:
BE MIRRORED FROM TYPICAL UNIT SHEETS.
SIDE FOR ACCESSIBILITY COMPLIANCE. VERIFY WITH OVERALL FLOORPLAN AS UNITS MAY
- PROVIDE TOILET TRIP LEVER ON SIDE OF TANK ADJACENT TO LAVATORY OR ON THE WIDE
COILED BEHIND REFRIGERATORS.
- PROVIDE 3/8" STOP WITH ESCUTCHEON 4’-0" A.F.F. WITH 10 L.F. OF 1/4" DIAMETER PEX
- WATER PIPING SHALL NOT BE LOCATED IN EXTERIOR WALL OR ATTIC SPACE.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL APARTMENT UNITS
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS
FOR WALL TYPES AND EXACT LOCATIONS OF RATED CONSTRUCTION.
TO MAINTAIN THE RATING OF THE CONSTRUCTION. REFER TO ARCHITECTURAL PLANS
PIPING (GROUTED TIGHT) OR SEALED WITH A U.L. APPROVED FIRE BARRIER SYSTEM
- ANY PENETRATION OF THE FIRE RATED CONSTRUCTION MUST BE MADE WITH METAL
UNIT SHUT-OFF VALVES
VALVES
RISER SHUT-OFF
1/4" UNIT PLUMBING PLAN
TO ADJACENT UNIT
PLUMBING LAYOUT SIMILAR
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
P
I
3
0
3
.
d
g
n
6
:
3
6
:
2
0
P
M
7
/
3
0
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
4
:
0
5
/
1
6
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
7
/
2
7
/
2
0
1
1
MO
D
E
L
:
P
l
o
t
S
h
e
e
t
j
a
w
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
2.2 DELUXE ’A’2.2 DELUXE ’B’