HomeMy WebLinkAbout022 EI233 Addendum 5REV.pdfEI233 TJL/TAR 1/8" FIRST FLOOR POWER & SYSTEMS PLAN 1.1 DELUXE 1209 1101 STANDARD 2.2 1103 2.2 DELUXE 1105 MECH E108 1109 1111 2.2 TRAD.2.2 DELUXE 1113 ’E2’ STAIR E107 1102 STANDARD 2.2 STANDARD 2.2 1108 1110 1.1 TRAD.1.1 TRAD. 1112 2.2 GRAND 11141104 DELUXE 1.1.5 1106 DELUXE 1.1.5 2.2 GRAND 1107 E105 IT E104 E103 ELECTSTORAGE E102 E106 HSKP STORAGE RESIDENTAL E101 D101 CORRIDOR E109 CORRIDOR ’E1’ STAIR 1.1.5 DELUXE 1208 RESIDENT APARTMENT SMOKE DETECTOR - ALTERNATE #1 LOCATED IN THE UNIT BATHROOM - ACCESSABLE UNITS TO HAVE AN ADDITIONAL AUDIO/VISUAL FIRE ALARM BEDROOMS AND LIVING SPACE - ACCESSABLE UNITS TO HAVE AUDIO / VISUAL FIRE ALARMS AT AT BEDROOMS AND LIVING SPACE - APARTMENT UNITS TO BE EQUIPPED W/ SYSTEM MINI HORN FIRE ALARMS SOUND A GENERAL ALARM AND AUTO-DIAL THE FIRE DEPARTMENT. ASSESS THE EVENT. PAST THE DELAY TIME PERIOD THE SYSTEM WILL DETERMINED BY THE OWNER / OPERATOR TO ALLOW FOR STAFF TO PAGER SYSTEM AND DELAY GENERAL ALARM BY A TIME PERIOD TO BE - MODULE TO BE PROGAMMED TO LOCALLY ANNUNCIATE EVENT TO STAFF FIRE ALARM SYSTEM MONITOR MODULE. - SMOKE DETECTOR WITH TYPE ’C’ CONTACTS TO BE CONNECTED TO - (1) SMOKE DETECTOR TO HAVE TYPE ’C’ AUXILLIARY CONTACTS WITH BATTERY BACK-UP. SMOKE DETECTORS TO BE INTERCONNECTED - UNIT SMOKE DETECTORS TO BE STAND ALONE TYPE, LINE VOLTAGE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM NOTE: VISUAL SIGNAL TO BE ACTIVATED BY BOTH THE IN-ROOM SMOKE E H D A B KEYED NOTES THIS SHEET ONLY L M N C - CABLE TV - TELEPHONE (4) 4" CONDUITS AT FLOOR 120V - 1‘ - 20AMP - 1P CIRCUIT (REA-32) -W/ (2) 4-PLEX RECEPTACLES WHITE AND BOLTED TO WALL TO 8’ A.F.F. 3/4" PLYWOOD PANEL PAINTED TELEPHONE/CABLE EQUIPMENT PANELS 20 AMP - 1P CIRCUIT (REA-33) 120V - 1‘ - MCA = 11.0 AMPS FURNACE F-2 (SO-139) F G J K 15 AMP - 1P CIRCUIT (REA-37) 120V - 1‘ - MCA = 1.8 AMP EXHAUST FAN EF-5 (SO-141) 15 AMP - 1P CIRCUIT (REA-37) 120V - 1‘ - MCA = 2.1 AMP EXHAUST FAN EF-8 (SO-143) 15AMP - 1P CIRCUIT (REA-35) 120V - 1‘ - 0.5 AMPS MOTORIZED SMOKE DAMPER 15 AMP - 1P CIRCUIT (REA-37) 120V - 1‘ - MCA = 2.1 AMP EXHAUST FAN EF-6 (SO-144) PAGER SYSTEM ALARM ANNUNCIATOR PANELS AND STAFF FIRE ALARM SYSTEM AND ANNUNCIATE AT CO DETECTOR TO BE CONNECTED TO INSTALLED BY FIRE ALARM CONTRACTOR - CARBON MONOXIDE DETECTOR PROVIDED AND DETECTOR MAY BE USED COMBINATION SMOKE DETECTOR / CO PAGER SYSTEM ALARM ANNUNCIATOR PANELS AND STAFF INDIVIDUAL APARTMENT UNIT AND AT FIRE ALARM SYSTEM AND ANNUNCIATE AT CO DETECTOR TO BE CONNECTED TO INSTALLED BY FIRE ALARM CONTRACTOR - CARBON MONOXIDE DETECTOR PROVIDED AND 20AMP - 1P CIRCUITS (REA-31) 120V - 1‘ - 100 WATTS VERIFY W/ F.A. CONTRACTOR FIRE ALARM NAC PANEL (SO-137) P HOUSE PANEL ’REA’ - FIRST FLOOR SERVES FIRST AND SECOND FLOOR COMMON SPACES 350 AMP - 3P - 120/208 V - 3‘ - 4 WIRE 1000 AMP - 3P - 120/208 V - 3‘ - 4 WIRE D A B C EF F G K J H H 20 AMP - 2P CIRCUIT (REA-39,41) 2 @ 208V - 1‘ - 1500 WATTS EACH W/ BUILT-IN THERMOSTAT (2) ELECTRIC BASEBOARD - BB-6 ELECTRICAL INSTALLATION) ERS PROVIDER PRIOR TO START OF (VERIFY QUANTITY AND LOCATION W/ 20AMP - 1P CIRCUIT (REA-34) 120V - 1‘ - 200W RECEIVER/TRANSMITTER RESPONSE CALL SYSTEM (ERS) @7’ A.F.F. FOR WIRELESS EMERGENCY (2) DUPLEX RECEPTACLES W/10"x10" J-BOX P APARTMENT DISTRIBUTION PANEL RADP-E 2 - 125 AMP - 3P - LOADCENTER 2.2 GRAND 3 UNIT STACK 2 - 125 AMP - 3P - LOADCENTER 2.2 CORNER 3 UNIT STACK 1 - 125 AMP - 3P - LOADCENTER 2.2 TRADITIONAL 3 UNIT STACK 3 - 125 AMP - 3P - LOADCENTER 2.2 STANDARD 3 UNIT STACK 2 - 125 AMP - 3P - LOADCENTER 2.2 DELUXE 3 UNIT STACK 2 - 125 AMP - 3P - LOADCENTER 1.15 DELUXE 3 UNIT STACK 2 - 125 AMP - 3P - LOADCENTER 1.1 TRADITIONAL 3 UNIT STACK (REA-36) (REA-36)(REA-36) (REA-36) (REA-36) (REA-36) (REA-36) (REA-38) GFI (REA-36) GFI/WP GFI/WP (REA-40)(REA-40) (REA-56) (REA-56)(REA-56)(REA-58)(REA-56)(REA-60)(REA-60) (REA-60) (REA-58) (REA-58) F (REA-60) CORNER B 2.2 CORNER B 2.2 1 1 1 1 1 1 STORAGE 1 16 APRIL 2012 ADDENDUM #5 REV. REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l In d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l INDEPENDENTINDEPENDENT C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ E I 2 3 3 . d g n 1 0 : 0 2 : 1 7 A M 4 / 1 3 / 2 0 1 2 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 4 / 1 3 / 2 0 1 2 MO D E L : D e f a u l t t a r B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL T T F F SS S S S S SSSS S S F VA FVAFVA F VA F VA F VA F VA S MM S F M F M MM MM MM MM MM MM MM MM MMMM MM MM MM F M FM C S FM F M F M FM S S S S S S C C S SS C FM F M S S S C F M S C S MM FM SC S S S FM FM C S MM FM FM C S S S F M C S S F M S FM F M S S S C F M FMSC S S FM F M S C S S FM S S F M C S FM FM S C S S S C S FM 4 4 C C C T S S FVA C