HomeMy WebLinkAbout022 MI306.pdfRJS MI3061/4" UNIT HVAC PLAN BEDROOM GREAT ROOM BEDROOM DEN KITCHEN DINING ENTRY SHOWER W.I.C. 1.1.5 DELUXE & 1.1.5 DELUXE SHOWER BATH W.I.C. 8x8 S10x8 S 175 CFM 14x6 SG-5 200 CFM 16x6 SG-5 NEAR FLOOR 175 CFM 14x8 RG-3 T 1’-0" 14x6 75 CFM 12x6 SG-5 75 CFM HF-1 NOTES: LIP PER EXHIBIT 410.1 OF NEC 2005 FROM SHOWER AND/OR BATHTUB MAINTAIN MIN 3’-0" CLEARANCE FOR LOCATION OF EXHAUST FANS, 4" ‘ E 75 CFM HF-1 4" ‘ E WC-2WC-1 WC-2 MT102 3 (IN ADDITION TO DUCT LINING) IN HVAC CLOSET EXTERNALLY INSULATE ALL DUCTWORK OUTSIDE WALL PITCH TOWARDS 4" ‘ E IN TRUSS SPACE 4" ‘ E IN TRUSS SPACE NEAR CEILING 14x6 RG-3 100 CFM 12x6 SG-5 DUCT LINER WITH 1/2" 16x10 O.D. 800 CFM RET 800 CFM SUP HC-2 INSULATE 14x6 DOWN DUCT LINER WITH" 16x10 O.D. 250 CFM 18x6 SG-5 14x10 R 12x8 S IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ DRYER VENT UP ON IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ E UP ON 625 CFM 24x14 RG-3 NEAR CEILING 14x6 RG-3 8x8 S 10x8 S 175 CFM 14x6 SG-5 200 CFM 16x6 SG-5 14x6 75 CFM 12x6 SG-5 75 CFM HF-1 4" ‘ E WC-2 WC-1 WC-2 (IN ADDITION TO DUCT LINING) IN HVAC CLOSET EXTERNALLY INSULATE ALL DUCTWORK OUTSIDE WALL PITCH TOWARDS 4" ‘ E IN TRUSS SPACE 4" ‘ E IN TRUSS SPACE NEAR CEILING 14x6 RG-3 100 CFM 12x6 SG-5 DUCT LINER WITH 1/2" 16x10 O.D. 800 CFM RET 800 CFM SUP HC-2 INSULATE 14x6 DOWN DUCT LINER WITH" 16x10 O.D. 250 CFM 18x6 SG-514x10 R 12x8 S 625 CFM 24x14 RG-3 NOTES: LIP PER EXHIBIT 410.1 OF NEC 2005 FROM SHOWER AND/OR BATHTUB MAINTAIN MIN 3’-0" CLEARANCE FOR LOCATION OF EXHAUST FANS, W.I.C. CAPPED ABOVE CEILING 4" ‘ DRYER VENT ABOVE CEILING 4" ‘ E CAPPED T 1’-0" IN 2ND FLOOR JOIST SPACE 3RD FLOOR DUCT RUNS 4"‘ DOWN FROM 3RD FLOOR. 1ST & 2ND FLOORS. 4" ‘ E UP ON 4" ‘ E NEAR CEILING 14x6 RG-3 TO MINIMIZE WIDTH OF SOFFIT TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE TO MINIMIZE WIDTH OF SOFFIT TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE TO MINIMIZE WIDTH OF SOFFIT TO EXTERIOR WALL AS POSSIBLE INSTALL DUCTWORK AS CLOSE NOTE NEAR FLOOR 175 CFM 14x8 RG-3 REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ MI 3 0 6 . d g n 1 0 : 0 8 : 2 6 A M 8 / 1 / 2 0 1 1 P L O T T E D O N : 4 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 8 / 1 / 2 0 1 1 MO D E L : P l o t S h e e t r j s B Y U S E R : A T S C A L E : U S I N G D R I V E R : D R A W I N G L I M I T L I N E 01 AUG 2011 FAX TEL COMBO UNIT