HomeMy WebLinkAbout024 MC220.pdfMC220 RJS Match Line M a tch L i n e Ma tc h Lin e M a t c h L in e PREPERATION SALON CORRIDOR TOILET TOILET FITNESS CENTER LIBRARY LIVING/ ARTS & CRAFTS A.L. MULTIPURPOSE TV ROOM MAIL STORAGE AL22 AL26 AL28 CORRIDOR AL23 AL24 AL25 AL29 AL27 C50 C51 C52 CORRIDOR C53 C48 C49 M a t c h L in e M a t c h L in e CORRIDOR JANITOR WOMEN MEN DINING TOILETTOILET SALON STORAGE CENTRAL DIRECTOR OPERATIONS ELECTRICAL WATER SERVICE MECHANICAL & STORAGE HSKPG. DIRECTOR HSKPG. ROOM CONFERENCE A.L. MARKETING VESTIBULE LOBBY CLERICAL RECEPTION KITCHEN SERVING ROOM BREAK SERVICES SOCIAL CORRIDOR WASHING DRYING PORT COUCHERE C46 C45 C44 C32 C33 C34 C30 C29 C43 C42 C41 C40 C37 C35 C36 C39 C38 CORRIDOR AL14 AL13 AL12 AL15 AL16 AL10 AL9 AL7 AL4 AL3 AL2 AL1 AL18 AL20 FILES COORDINATOR LIFESTYLE MAINTENANCE SERVER ROOM/IT AL11 DRYING C31 AL5 DINING PRIVATE AL21 CORRIDOR AL8 DIRECTOR MEDICAL DIRECTOR A.L. DOOR 1" UNDERCUT DOOR 1" UNDERCUT DOOR 1" UNDERCUT DOOR 1" UNDERCUT SWITCH WITH LITE INTERLOCK 75 CFM EF-6 6"‘ E WC-5 WC-5 6 "‘ E SWITCH WITH LITE INTERLOCK 75 CFM EF-6 FD-B FD-B F D - B FD-B 18x10 R 18x10 S 14x14 UP 18x10 S 1 8 x 10 R 1 8 x 10 S 24x14 RG-2 24x8 250 CFM 10"ß NK SG-1 350 CFM 10"ß NK SG-1 1 0 "ß S 1 0 "ß S VD VD 1 0 "ß S 325 CFM 16x8 SG-2 6 "ß S VD 75 CFM 8x8 SG-2 VD RUNS CONTINUOUS 100 CFM EF-7 FD-B 8"‘ E 10x10 S 12x10 S VD VD VD VD VD VD VDVD 100 CFM 8x8 SG-2 8"‘ S DOOR 1" UNDERCUT 8 " ‘ S 8 " ‘ S 8 " ‘ S 8 " ‘ S 8 " ‘ S DBU-1 1/2 DOWN IN WALL. SPILL ON GRADE 3/4" CONDENSATE PIPING FD-B F D - B FD-B 1 0 " ‘ S 1 0 " ‘ S 10x10 S 18x10 S 10x10 S12x10 250 CFM 10"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 2 4 x 1 0 S 250 CFM 20x6 SG-2 200 CFM 8"ß NK SG-1 VD 16x16 S 10"ß R VD 14x12 R 14x12 R 18x10 R 16x16 UP 18x10 R1 8 x 10 R 8"‘ S 12x10 S 14x12 S 1 8 x 10 S 1 0 x 1 0 S 10"ß S 10"ß S 10"ß S 10"ß S VD VD VD VD 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 200 CFM 12x8 SG-2 200 CFM 12x8 SG-2 16x16 UP 1 2 x 1 0 S 16x12 R 1 6 x 1 2 R 14x10 R 1 0 x 10 S 8"‘ S 8"‘ S 225 CFM 10"ß NK SG-1 225 CFM 10"ß NK SG-1 250 CFM 10"ß NK SG-1 400 CFM 10"ß NK RG-1 400 CFM 10"ß NK RG-1 400 CFM 10"ß NK RG-1 400 CFM 10"ß NK RG-1 14x12 S 650 CFM 16x16 RG-2 950 CFM 24x16 RG-2 VD WC-7 HOOD BY OTHERS CONNECT TO HOOD. 3 1/4x10 E. - T STAT OPERATION 400 CFM - RETURN AIR 400 CFM - SUPPLY AIR CONDENSER ON GRADE FC-3 FAN COIL DOWN IN WALL. SPILL ON GRADE 3/4" CONDENSATE PIPING 400 CFM 12"ß NK RG-1 160 CFM 8"ß NK SG-1 175 CFM 12x8 SG-2 140 CFM 12x6 SG-2 200 CFM 8"ß NK SG-1 175 CFM 12x8 SG-2 175 CFM 12x8 SG-2 1 2 " ‘ S 12" ‘ S 1 2 " ‘ R 12" ‘ 10"‘ S VD VD VD VD VD VD VD 8"‘ S 8"‘ S 8"‘ S 8"‘ S 8 " ‘ S 8 " ‘ S F D - B 14x14 S 28x8 S 14x14 R 14x14 UP 350 CFM 10"ß NK RG-1 10"ß R 8 " ‘ R 160 CFM 8"ß NK RG-1 VD AND THIMBLES. STRAPS, FIRESTOP SUPPORTS CAP, STORM COLLAR, FLASHING, SUPPORT INCLUDING, BUT NOT LIMITED TO: WEATHER PROVIDE ALL REQUIRED ACCESSORIES FIRE PLACE FLUE PER MANUFACTURER. 4 1/2" INNER 7 1/2" OUTER CO-AXIAL DV FCCU-3 14x8 S 8 " ‘ S 8 " ‘ S 8 " ‘ S 1 0 x 8 S 1 0 x 8 S 10 x 8 S VD 1 2 x 1 2 R 20x8 690 CFM 24x12 RG-2 200 CFM 10"ß NK SG-1 200 CFM 10"ß NK SG-1 DOOR 1" UNDERCUT 225 CFM 8"‘ NK SG-1 DOOR 1" UNDERCUT DOOR 1" UNDERCUT DOOR 1" UNDERCUT DOOR 1" UNDERCUT UP TO EF-15 10x10 E 10"‘ E 6 "‘ E 6 "‘ E 6 "‘ E 6 "‘ E 75 CFM 6x6 EG-2 75 CFM 6x6 EG-2 75 CFM 6x6 EG-2 75 CFM 6x6 EG-2 VD VD VD VD 10 "‘ E 6 "‘ S VD 100 CFM 8x6 SG-2 100 CFM 8x6 SG-2 6 "‘ S VD 8 "‘ S VD VD TO RTU-5 FULL SIZE UP16 x 1 2 R 20x14 S 20x16 R 1 6 x 12 R VD VD VD 500 CFM 12" ‘ NK SG-1 500 CFM 12" ‘ NK SG-1 500 CFM 12" ‘ NK SG-1 500 CFM 12" ‘ NK SG-1 1 2 " ‘ S 12" ‘ S VD VD 10"‘ NK TG-1 200 CFM 10"‘ NK TG-1 10"‘ FLEX 400 CFM 12" NK RG-1 400 CFM 12" NK RG-1 400 CFM 12" NK RG-1 400 CFM 12" NK RG-1 500 CFM 12"‘ NK EG-1 TO EF-16 12"‘ E UP TO IH-1 28X28 UP VENT UP 10"‘ DRYER VENT UP 10"‘ DRYER INSULATED 28x28 INTAKE 12" ‘ S 12" ‘ S 16x12 S 1 6 x 1 2 DOWN IN WALL. SPILL ON GRADE 3/4" CONDENSATE PIPING DBU-2 DOOR 1" UNDERCUT 150 CFM 8" ‘ NK SG-1 150 CFM 8" ‘ NK SG-1 175 CFM 8" ‘ NK SG-1 175 CFM 8" ‘ NK SG-1 175 CFM 8" ‘ NK SG-1 150 CFM 8" ‘ NK SG-1 150 CFM 8" ‘ NK SG-1 8" ‘ NK RG-1 8" ‘ NK RG-1 8" ‘ NK RG-1 8" ‘ NK RG-1 8" ‘ NK RG-1 8" ‘ NK RG-1 8" ‘ NK RG-1 8 "‘ S 6 "‘ S 8 "‘ S 8"‘ S 8 "‘ S 8 "‘ S VD VDVDVD VD VD VD VD SWITCH WITH LITE INTERLOCK 75 CFM EF-6 SWITCH WITH LITE INTERLOCK 75 CFM EF-6 6 "‘ E 6 "‘ E 6"‘ UP 150 CFM 8" ‘ NK SG-1 175 CFM 8" ‘ NK SG-1 350 CFM 10" ‘ NK SG-1 175 CFM 8" ‘ NK SG-1 125 CFM 8x8 SG-2 150 CFM 12x6 SG-2 8 "‘ S 8 "‘ S 8 "‘ S 8 "‘ S 8 "‘ S 10"‘ S 1 0 "‘ S 8 "‘ S - TSTAT OPERATION 200 CFM RETURN AIR 200 CFM SUPPLY AIR FC-6 FAN COIL VDVD VD VD VD VD VD 8" ‘ NK RG-1 8" ‘ NK RG-1 12"‘ FLEX 1 0 "‘ E 10"‘ UP 200 CFM EF-8 8"‘ UP 8"‘ UP 8"‘ UP RUNS CONTINUOUS 200 CFM EF-8 HUB DRAIN BY PC DOWN IN WALL TO HUD DRAIN. 3/4" CONDENSATE PIPING 100 CFM 12x8 SG-2 200 CFM 14x8 SG-2 VD 10"‘ S 10"‘ R 200 CFM 14x8 RG-2 6"‘ UP CONTINUOUS RUNS 75 CFM EF-6 18x12 AD-1 @ 12" ABOVE GRADE 300 CFM 18x12 LV-1 WC-3 8"‘ E EXPOSED RATED CEILING INSTALL BELOW 300 CFM EF-17 75 CFM 6" ‘ NK SG-1 DBU-3/4 DOOR 3/4" UNDERCUT 8 "‘ R 8"‘ R 8 "‘ R 8 "‘ R 8 "‘ R 8 "‘ R 8 "‘ R WORK ROOM AL6 8" ‘ NK RG-1 1 2 x 1 0 S 1 2 x 1 0 20x10 S 8"‘ R 250 CFM 14x8 SG-2 200 CFM 14x8 SG-2WAITING AL19 10"‘ S 10"‘ S VD VD - TSTAT OPERATION 300 CFM RETURN AIR 300 CFM SUPPLY AIR FC-1 FAN COIL DOWN IN WALL. SPILL ON GRADE 3/4" CONDENSATE PIPING 10x10 S 10x8 S 10x10 S 10x8 S 14x10 R24x10 R 10x8 R TO RTU-3 FULL SIZE UP VD 8 "‘ S 8 "‘ S 200 CFM 8" ‘ NK SG-1A 200 CFM 8"‘ NK SG-1 DOOR 1" UNDERCUT DOOR 1" UNDERCUT DOOR 1" UNDERCUT CONTINUOUS RUNS 125 CFM EF-7 CONTINUOUS RUNS 125 CFM EF-7 8"‘ E 8"‘ E 125 CFM 12x6 SG-2 125 CFM 12x6 SG-2 10" ‘ NK RG-1 10 "‘ R 300 CFM 10" ‘ NK SG-1 100 CFM 6" ‘ NK RG-1 RUNS CONTINUOUS 375 CFM EF-17 DOOR 1" UNDERCUT 225 CFM 12x12 TG-2 12x12 TG-2 200 CFM 14x8 SG-2 VD TO RTU-4 FULL SIZE UP 10x10 S 14x10 S 14x10 S 12x10 S 22x10 R 14x10 R 1 HOUR TIMER 10" ‘ NK RG-110x8 S DBU-1 DOOR 1" UNDERCUT 10"‘ S VD 1 0 "‘ R WITH RTU-6 INTERLOCK 200 CFM EF-8 8"‘ S 1 0 "‘ S TO RTU-5 FULL SIZE UP TO RTU-6 FULL SIZE UP SD 24x14 R 2 4 x 1 4 R 1 6 x 1 4 R 20x20 RG-2 RISE UP 14x14 R 20x20 RG-2 DOWN 14x14 R 10 x 1 0 S 2 4 x 1 4 S 24x14 S 24x12 S 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 250 CFM 14x8 SG-2 RISE UP 22x12 S 22x12 S 20x12 S 18x12 S 18x10 S 14x10 S 10x10 S VD VD VD VD VD VD VD VD 8x8 S 12" ‘ NK RG-1 150 CFM 10" ‘ NK SG-1 150 CFM 10" ‘ NK SG-1 VD VD 10"‘ S 160 CFM 8" ‘ NK SG-1 1 2 "‘ R 1 2 "‘ S 12"‘ R 12"‘ S 225 CFM 20x6 SG-2 225 CFM 20x6 SG-2 225 CFM 20x6 SG-2 VDVD VD VD 1 6 x 1 4 R 6"‘ R DOWN 8x8 S DOWN 8x8 S 1 4 x 1 4 R 18x12 R 10"‘ INSULATED FLEX CORRIDOR AL17 EACH 325 CFM 10"‘ RG-1 24x14 RISE UP 16x14 R 20x14 S 8x8 S 8x8 S8x8 S 16 x 1 0 S 8x14 S 8x14 S VD 200 CFM 14x8 SG-2 8"‘ S 8"‘ S 1 0 "‘ S 8 "‘ S 8 "‘ S DOWN 16x14 R 14"‘ INSULATED FLEX 14"‘ INSULATED FLEX 14"‘ RG-1 14"‘ RG-1 SD SD 8"‘ INSULATED FLEX 8 x 1 4 S DOWN 8x8 S 8" ‘ NK RG-1 SET FOR 85 DEG. ACTING TSTAT. REVERSE DRYER OPERATIONS INTERLOCK WITH BOTH AD-1 AT 1 FOOT BELOW CEILING DOWN TO 28/14 OPENING 28/14 COMB AIR DUCT AT 1 FOOT ABOVE FLOOR DOWN TO 28/14 OPENING 28/14 COMB AIR DUCT 1/8" FIRST FLOOR PARTIAL HVAC PLAN UP THRU ROOF. COMBUSTION AIR INTAKE 10"‘ ’B’ VENT OFFSET OVER STORAGE TANK HW HEATERS DOMESTIC UP THRU ROOF. 10"‘ AL29-4C SEALED VENTING REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ MC 2 2 0 . d g n 9 : 4 7 : 3 7 A M 8 / 1 / 2 0 1 1 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 8 / 1 / 2 0 1 1 MO D E L : D e f a u l t r j s B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL COMMONS T T T T T T T T T T T T T T T COLD PAK FREEZER PARAFFIN BATH - COUNTER WALL PULLEY - WALLWEIGHT RACK