HomeMy WebLinkAbout029 EI302 Addendum 5REV.pdfEI3021/4" UNIT ELECTRICAL PLANS
TJL/TAR
G
H
30A - 2P
COMBINATION UNIT
WASHER / DRYER
20 AMP - 1P
REFRIGERATOR
40 AMP - 2P
RANGEB
C
D
E
A
NOTES FOR THIS SHEET ONLY
J
K
L
INSTALLATION - TYPICAL FOR ALL UNITS.
AVOID CONFLICT WITH THE MEDICINE CABINET
INTERIOR ELEVATION DRAWINGS SO AS TO
TO BE DETERMINED PER ARCHITECTURAL
OF BATHROOM SWITCHES AND OUTLETS ARE
THE HORIZONTAL AND VERTICAL POSITION
NOTE:
TENANT TO PROVIDE FIXTURE
FAN SUPPORT TO BE CENTERED IN ROOM.
SWITCHED JUNCTION BOX FOR PADDLE
TENANT TO PROVIDE FIXTURE
SWITCHED JUNCTION BOX.
M
20 AMP - 1P
FOR WASTE DISPOSAL
SWITCHED OUTLET BELOW SINK
’ADA’ UNIT NOTES
- AUDIO/VISUAL FIRE ALARM DEVICE
BATH
FIRE ALARM DEVICE
FIRE ALARM SYSTEM TO PROVIDE POWER TO VIBRATING PAD
- DUPLEX RECEPTACLE NEAR BED LOCATION TIED INTO
- VISUAL ALARM
- SMOKE DETECTOR W/SYSTEM PROGRAMMABLE SOUNDER BASE
BEDROOM
- DOOR BELL W/ INDICATOR LIGHT
LIVING ROOM OR HALL AREA OF BEDROOM
- AUDIO/VISUAL FIRE ALARM DEVICE
LIVING ROOM
TO BE DESIGNATED FOR USE BY THE PHYSICALLY DISABLED
IN ADDITION TO TYPICAL UNIT NOTES AT THOSE UNITS
NOTE:
NEC ART. 210.12 (B)
ARC FAULT INTERUPTER PROTECTED PER
LIVING, DINING, DEN, HALLWAYS, ETC. TO BE
REMAINING RECEPTACLES IN BEDROOMS,
PROTECTED PER NEC ART. 210.8 (A)
TO BE GROUND FAULT INTERUPTER (GFI)
RECEPTACLES IN KITCHEN AND BATHS
SWITCH DISCONNECT
W/ UNDERCABINET
20 AMP - 1P
DISHWASHER
E
WIRED BY ELECTRICAL CONTRACTOR
SUPPLIED AND INSTALLED BY OTHERS
20 AMP - 1P
120V - 1‘ - 2.5 AMP
RANGEHOOD W/ LIGHT
SUPPLIED AND INSTALLED BY OTHERS
IN SELF SPACE - UNIT IS
PROVIDE OUTLET BEHIND UNIT
20 AMP - 1P
120V - 1‘ - 1100 WATTS
MICROWAVE OVEN
BY DIV. 16
PROVIDED AND INSTALLED BY DIV. 15 AND WIRED
20AMP - 1P CIRCUIT - GFI
120V - 1‘ - .75AMP (FAN) - 250 WATT (HEAT LAMP)
HF-1 EXHAUST FAN/HEATER
30 AMP - 2P CIRCUIT
208V - 1‘ - MCA=21.2 AMPS
MAGIC PAK HVAC UNIT HC-2 1/2
S
DC
AFI
HVAC
BD
-WP
GFI
S3
KITCHEN
C
E
B
CW
AFI
SS
D
A
S
S
F
RD
RC
J
J
L
RF
RE-3 GFI
S
S
S T
SHOWER
ST
CS
H
M
AFI
AFI
C2
AFI
AFI
C2
OUTLET ONLY
SWITCH TOP
BEDROOM
S
S
C2
AFI
S
D
OUTLET ONLY
SWITCH TOP
W.I.C.
BEDROOM
LIVING ROOM
ENTRY
BATH
P & SH
PATIO
GFIGFI
GFI
AC
GFI
AC
GFIGFI
DINING
P & SH
P & SH
P
&
S
H
P
&
S
H
RA
S3
S
3
RF
3
-
0
3
-
0
CS
RG
GFI
AFI
S
S
S
S
S
3
C2
RE-3
CA
S
S
RD GFI
AFI
AFI
S
AFI
J
S
C2
C2
AFI
AFI
AFI
AFI
AFI
AFI
AFI
K K
1‘ - 3 WIRE
100 AMP - 2P - 120/208V
LOADCENTER PANEL 2.2TRD
S PSB
S PSB
S PSB
- TYPICAL AT 48" A.F.F.
CABLE CONNECTORS
FOR TELEVISION / TELEPHONE
RECESSED JUNCTION BOX W/ COVER
J
GKITCHEN
GFI
GFIGFI
GFI
C
E
B
CW
GFI
AC
AFI
AFI
S S
D
A
S
S
S
GFI
F
GFI-WPS
AFI
HVAC
BD
S3
RD
RD
RC RA
J
J
L
JRG
RF
RF
RB
3
-
03
-
0
RE-3
GFI
RE-3
GFI
S
S
S T
CS
K
SHOWER
S
S
S T
K
CS
H
G
M
S
AFI
AFI
C2
AFI
AFI
C2
OUTLET ONLY
SWITCH TOP
BEDROOM
S
S
S
3
C2
AFI
AFI
C2
C2
AFI
AFI
C2
AFI
S
3
S
S
S
S
S
3
AFI
AFI
AFI
AFI
SD
AFI
OUTLET ONLY
SWITCH TOP
OUTLET ONLY
SWITCH TOP
W.I.C.
BEDROOM
LIVING ROOM
ENTRY
BATH
P & SH
P & SH
P & SH
P & SH
P
&
S
H
PATIO
DA
AFI
1‘ - 3 WIRE
100 AMP - 2P - 120/208V
LOADCENTER PANEL 2.2 CNR
S PSB
S PSB
S PSB
J
2.2 TRADITIONAL
AREA = 1202 SQFT
UNITS 1111, 1203, 1503
2.2 CORNER
AREA = 1161 SQFT
UNITS 1101, 1109, 1301, 1402, 1508
NOTE:
FAN AND LIGHT CONTROLS
FEEDER TO THIS BOX FOR FUTURE SEPARATE
ELECTRICAL CONTRACTOR TO PROVIDE 4-WIRE
TO THE LISTING INSTALLATION INSTRUCTIONS.
THEIR MANUFACTURER AND SECURED ACCORDING
(PADDLE) FAN LISTED, SHALL BE MARKED BY
ANY AREA PERIMETER WALL SHALL BE CEILING
IN DWELLING UNITS TWO FEET OR MORE FROM
CEILING MOUNTED LIGHTING J - BOXES
2.2 CORNER B
AREA = 1212 SQFT
UNITS 1101, 1109, 1301, 2101, 2109, 2301, 3101, 3109 3301
RG
RF
AFI
AFI
C2
C2
AFI
S
S
AFI
AFI
OUTLET ONLY
SWITCH TOP
W.I.C.
BEDROOM
P & SH
P & SH
P
&
S
H
S PSB
3
-
0
RE-3
GFI
S
S
S T
CS
K
SHOWER
AFI
AFIAFI
AFI
RBS
RB
1 1
1 16 APRIL 2012
ADDENDUM #5 REV.
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
E
I
3
0
2
.
d
g
n
1
2
:
2
6
:
5
9
P
M
4
/
1
3
/
2
0
1
2
P
L
O
T
T
E
D
O
N
:
4
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
4
/
1
3
/
2
0
1
2
MO
D
E
L
:
D
e
f
a
u
l
t
t
a
r
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL