Loading...
HomeMy WebLinkAbout029 EI302 Addendum 5REV.pdfEI3021/4" UNIT ELECTRICAL PLANS TJL/TAR G H 30A - 2P COMBINATION UNIT WASHER / DRYER 20 AMP - 1P REFRIGERATOR 40 AMP - 2P RANGEB C D E A NOTES FOR THIS SHEET ONLY J K L INSTALLATION - TYPICAL FOR ALL UNITS. AVOID CONFLICT WITH THE MEDICINE CABINET INTERIOR ELEVATION DRAWINGS SO AS TO TO BE DETERMINED PER ARCHITECTURAL OF BATHROOM SWITCHES AND OUTLETS ARE THE HORIZONTAL AND VERTICAL POSITION NOTE: TENANT TO PROVIDE FIXTURE FAN SUPPORT TO BE CENTERED IN ROOM. SWITCHED JUNCTION BOX FOR PADDLE TENANT TO PROVIDE FIXTURE SWITCHED JUNCTION BOX. M 20 AMP - 1P FOR WASTE DISPOSAL SWITCHED OUTLET BELOW SINK ’ADA’ UNIT NOTES - AUDIO/VISUAL FIRE ALARM DEVICE BATH FIRE ALARM DEVICE FIRE ALARM SYSTEM TO PROVIDE POWER TO VIBRATING PAD - DUPLEX RECEPTACLE NEAR BED LOCATION TIED INTO - VISUAL ALARM - SMOKE DETECTOR W/SYSTEM PROGRAMMABLE SOUNDER BASE BEDROOM - DOOR BELL W/ INDICATOR LIGHT LIVING ROOM OR HALL AREA OF BEDROOM - AUDIO/VISUAL FIRE ALARM DEVICE LIVING ROOM TO BE DESIGNATED FOR USE BY THE PHYSICALLY DISABLED IN ADDITION TO TYPICAL UNIT NOTES AT THOSE UNITS NOTE: NEC ART. 210.12 (B) ARC FAULT INTERUPTER PROTECTED PER LIVING, DINING, DEN, HALLWAYS, ETC. TO BE REMAINING RECEPTACLES IN BEDROOMS, PROTECTED PER NEC ART. 210.8 (A) TO BE GROUND FAULT INTERUPTER (GFI) RECEPTACLES IN KITCHEN AND BATHS SWITCH DISCONNECT W/ UNDERCABINET 20 AMP - 1P DISHWASHER E WIRED BY ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED BY OTHERS 20 AMP - 1P 120V - 1‘ - 2.5 AMP RANGEHOOD W/ LIGHT SUPPLIED AND INSTALLED BY OTHERS IN SELF SPACE - UNIT IS PROVIDE OUTLET BEHIND UNIT 20 AMP - 1P 120V - 1‘ - 1100 WATTS MICROWAVE OVEN BY DIV. 16 PROVIDED AND INSTALLED BY DIV. 15 AND WIRED 20AMP - 1P CIRCUIT - GFI 120V - 1‘ - .75AMP (FAN) - 250 WATT (HEAT LAMP) HF-1 EXHAUST FAN/HEATER 30 AMP - 2P CIRCUIT 208V - 1‘ - MCA=21.2 AMPS MAGIC PAK HVAC UNIT HC-2 1/2 S DC AFI HVAC BD -WP GFI S3 KITCHEN C E B CW AFI SS D A S S F RD RC J J L RF RE-3 GFI S S S T SHOWER ST CS H M AFI AFI C2 AFI AFI C2 OUTLET ONLY SWITCH TOP BEDROOM S S C2 AFI S D OUTLET ONLY SWITCH TOP W.I.C. BEDROOM LIVING ROOM ENTRY BATH P & SH PATIO GFIGFI GFI AC GFI AC GFIGFI DINING P & SH P & SH P & S H P & S H RA S3 S 3 RF 3 - 0 3 - 0 CS RG GFI AFI S S S S S 3 C2 RE-3 CA S S RD GFI AFI AFI S AFI J S C2 C2 AFI AFI AFI AFI AFI AFI AFI K K 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 2.2TRD S PSB S PSB S PSB - TYPICAL AT 48" A.F.F. CABLE CONNECTORS FOR TELEVISION / TELEPHONE RECESSED JUNCTION BOX W/ COVER J GKITCHEN GFI GFIGFI GFI C E B CW GFI AC AFI AFI S S D A S S S GFI F GFI-WPS AFI HVAC BD S3 RD RD RC RA J J L JRG RF RF RB 3 - 03 - 0 RE-3 GFI RE-3 GFI S S S T CS K SHOWER S S S T K CS H G M S AFI AFI C2 AFI AFI C2 OUTLET ONLY SWITCH TOP BEDROOM S S S 3 C2 AFI AFI C2 C2 AFI AFI C2 AFI S 3 S S S S S 3 AFI AFI AFI AFI SD AFI OUTLET ONLY SWITCH TOP OUTLET ONLY SWITCH TOP W.I.C. BEDROOM LIVING ROOM ENTRY BATH P & SH P & SH P & SH P & SH P & S H PATIO DA AFI 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 2.2 CNR S PSB S PSB S PSB J 2.2 TRADITIONAL AREA = 1202 SQFT UNITS 1111, 1203, 1503 2.2 CORNER AREA = 1161 SQFT UNITS 1101, 1109, 1301, 1402, 1508 NOTE: FAN AND LIGHT CONTROLS FEEDER TO THIS BOX FOR FUTURE SEPARATE ELECTRICAL CONTRACTOR TO PROVIDE 4-WIRE TO THE LISTING INSTALLATION INSTRUCTIONS. THEIR MANUFACTURER AND SECURED ACCORDING (PADDLE) FAN LISTED, SHALL BE MARKED BY ANY AREA PERIMETER WALL SHALL BE CEILING IN DWELLING UNITS TWO FEET OR MORE FROM CEILING MOUNTED LIGHTING J - BOXES 2.2 CORNER B AREA = 1212 SQFT UNITS 1101, 1109, 1301, 2101, 2109, 2301, 3101, 3109 3301 RG RF AFI AFI C2 C2 AFI S S AFI AFI OUTLET ONLY SWITCH TOP W.I.C. BEDROOM P & SH P & SH P & S H S PSB 3 - 0 RE-3 GFI S S S T CS K SHOWER AFI AFIAFI AFI RBS RB 1 1 1 16 APRIL 2012 ADDENDUM #5 REV. REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ E I 3 0 2 . d g n 1 2 : 2 6 : 5 9 P M 4 / 1 3 / 2 0 1 2 P L O T T E D O N : 4 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 4 / 1 3 / 2 0 1 2 MO D E L : D e f a u l t t a r B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL