HomeMy WebLinkAbout029 MA210.pdfMA210
RJS
12x8 S
VENTING UP
FURNACE
24x8 DOWN
-CONTINUOUS BLOWER OPERATION
150 CFM OUTSIDE AIR
450 CFM RETURN AIR
600 CFM SUPPLY AIR
-CU-1 1/2 ON ROOF
F-1 1/2 FURNACE
WC-3
16
x
8
S
16x8 R
8
"‘
E
WC-4
DOOR 1"
UNDERCUT 200 CFM
8"ß NK
SG-1
200 CFM
8"ß NK
SG-1
200 CFM
8"ß NK
SG-18"‘ S VDVD VD
VD
VD
200 CFM
8"ß NK
SG-1
200 CFM
8"ß NK
SG-1
200 CFM
8"ß NK
SG-1
200 CFM
8"ß NK
SG-1
10x6 S10x10 S
VD
VD
VD
VD
200 CFM
16x6
SG-2
200 CFM
16x6
SG-2
150 CFM
14x6
SG-2
200 CFM
16x6
SG-2
175 CFM
16x6
SG-2
175 CFM
16x6
SG-2
VD
VD
1
0
x
6
S
VD
175 CFM
16x6
SG-2
175 CFM
16x6
SG-2
10x10 S
1
8
x
1
0
S
2
2
x
1
0
S
22x10 S
24x10 S
VD
VD
VD
VD
10"ß S
10"ß S
10"ß R
1
0
"ß
R
VD
1
8
x
1
0
R
1
2
x
8
E
8
"‘
E
VD
VD
12x10 S
1
2
x
1
0
S
DBU-2
FD-B
DBU-2
12x10 R
150 CFM
14x6
SG-2
8"‘ S
VD
VD
16x10 S16x10 S
12x10 S
225 CFM EA
8"ß NK
(2) RG-1
VD
VD 8x8 S
8
x
8
S
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
175 CFM
8x8
RG-2VD
VD
75 CFM
6x6
EG-2
-CONTINUOUS BLOWER OPERATION
300 CFM OUTSIDE AIR FROM HRV-2
700 CFM RETURN AIR
1000 CFM SUPPLY AIR
-CU-2 1/2 ON ROOF
F-2 1/2 FURNACE
PANEL
ACCESS
-CONTINUOUS BLOWER OPERATION
450 CFM OUTSIDE AIR FROM HRV-2
1050 CFM RETURN AIR
1500 CFM SUPPLY AIR
-CU-4 ON ROOF
F-4 FURNACE
-CONTINUOUS BLOWER OPERATION
200 CFM OUTSIDE AIR FROM HRV-2
400 CFM RETURN AIR
600 CFM SUPPLY AIR
-CU-1 1/2 ON ROOF
F-1 1/2 FURNACE
-CONTINUOUS BLOWER OPERATION
800 CFM OUTSIDE AIR FROM HRV-3
800 RETURN AIR
1600 CFM SUPPLY AIR
-CU-4 ON ROOF
F-4 FURNACE
-CONTINUOUS BLOWER OPERATION
450 CFM OUTSIDE AIR FROM HRV-2
1050 CFM RETURN AIR
1500 CFM SUPPLY AIR
-CU-4 ON ROOF
F-4VAV FURNACE
300 CFM
10"ß NK
SG-1A
300 CFM
10"ß NK
SG-1A
200 CFM
12x8
SG-2
200 CFM
12x8
SG-2
200 CFM
12x8
SG-2
300 CFM
12x10
RG-2
300 CFM
12x10
RG-2
EDH-1 1/2
EDH-1 1/2
EDH-1 1/2EDH-1 1/2EDH-1 1/2EDH-1 1/2EDH-1 1/2EDH-1 1/2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
8x8 S
8x8 S
8x8 S8x8 S 8x8 S
8x8 S
8x8 S8x8 S8x8 S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
VD
VD
VD VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VDVD
VDVD
VD
75 CFM
6x6
EG-2
8"‘ E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD75 CFM
6x6
EG-2
6"‘ E
VD
75 CFM
6x6
EG-2
6"‘ E
VD
6"‘ E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD75 CFM
6x6
EG-2
6
"‘
E
VD
75 CFM
6x6
EG-2
VD
8"‘ OA INSULATE
75 CFM
6x6
EG-2
175 CFM
8x8
RG-2
8"‘ R
VD
175 CFM
8x8
RG-2
8"‘ R
VD
175 CFM
8x8
RG-2
VD
175 CFM
8x8
RG-2
8"‘ R
VD
175 CFM
8x8
RG-2
8"‘ R
VD
175 CFM
8x8
RG-2
VD
175 CFM
8x8
RG-2
8"‘ R
VD
175 CFM
8x8
RG-2
VD
175 CFM
8x8
RG-2 8"‘ RVD
G109
ACTIVITY
LIVING
G110
DINING
H102
EQUIPMENT
ELEVATOR
G104
STORAGE
GENERAL
G105
COORDINATOR
PROGRAM
G103
OFFICE
ATTENDANT
G102
#4
ELEV.
ELEC.
H116
LAUNDRY
H114
LINEN
H115
H110
FOYER
MECH.
H113
SPA
H111
H109
TOILET
H101
CORRIDOR
PANTRY
SERVING
H103
H104
TOILET
H108
TV ROOM
UNIT A
1711 1708
UNIT A
STAIR ’G’
1709
UNIT A
1707
UNIT A
1706
UNIT A
1704
UNIT D
1702
UNIT E
1705
UNIT A
1703
UNIT A
1701
UNIT A
1801
UNIT A UNIT A
1803
1805
UNIT B
1807
UNIT F
1809
UNIT A
UNIT C
1802
1804
UNIT G
1806
UNIT C 1808
UNIT A
1810
UNIT A
1812
UNIT A
H106
HSKP
1811
UNIT A
1813
UNIT A
1815
UNIT E
1817
UNIT D
1819
UNIT A
STAIR ’H’
H107
MECH
H105
MECH
H117
MECH
BY OTHERS
TO FLOOR DRAIN. FLOOR DRAIN
3/4" CONDENSATE DOWN IN WALL
BY OTHERS
TO FLOOR DRAIN. FLOOR DRAIN
3/4" CONDENSATE DOWN IN WALL
SOILED
ENTRY
MECH
H112
H100
G101
G106
G111
MECH
G107
12x10
75 CFM
6x6
EG-2
VD
6
"‘
E
CONTINUOUS
RUNS
125 CFM
EF-7
175 CFM
8x8
RG-2
VD
8
"‘
R
6
"‘
E
VD
75 CFM
6x6
EG-2
EDH-1 1/2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
VD
VD
VD
VDVD
VD
VD
VD
VD
VD
VD
VD
8x8 S8x8 S8x8 S
8x8 S
8x8 S
8x8 S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
8
x
8
S
EDH-1 1/2EDH-1 1/2
EDH-1 1/2
EDH-1 1/2
EDH-1 1/2
6
"‘
E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD
75 CFM
6x6
EG-2
6
"‘
E
VD
75 CFM
6x6
EG-2
175 CFM
8x8
RG-2
VD
8
"‘
R
175 CFM
8x8
RG-2VD
8
"‘
R
175 CFM
8x8
RG-2
VD
8
"‘
R
175 CFM
8x8
RG-2
VD
8"‘ R
175 CFM
8x8
RG-2
VD
8
"‘
R
EDH-2
UP
24x10 E
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
8x8 S
8
x
8
S
VD
VD
75 CFM
6x6
EG-2 6"‘ EVD
175 CFM
8x8
RG-2
8
"‘
R
VD
EDH-2
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2 VD
VD
8
x
8
S
8x8 S
175 CFM
8x8
RG-2
8"‘ R
VD
75 CFM
6x6
EG-2
6"‘ E
VD
125 CFM
8x6
SG-2
8
x
8
S
125 CFM
8x6
SG-2
VD
VD
8x8 SEDH-1 1/2
175 CFM
8x8
RG-2VD
8"‘ R
75 CFM
6x6
EG-2
VD 6"‘ E
125 CFM
8x6
SG-2VD
VD
8
x
8
S
125 CFM
8x6
SG-2
EDH-1 1/2 8x8 S
75 CFM
6x6
EG-2 VD
6"‘ E
175 CFM
8x8
RG-2
VD
8"‘ R
EDH-2
125 CFM
8x6
SG-2
VD
VD125 CFM
8x6
SG-2
8
x
8
S
8x8 S EDH-1 1/2
75 CFM
6x6
EG-2VD
6"‘ E
175 CFM
8x8
RG-2
VD
8"‘ R
125 CFM
8x6
SG-2
VD
VD
125 CFM
8x6
SG-2
8
x
8
S
8x8 S EDH-1 1/2
75 CFM
6x6
EG-2VD6"‘ E
175 CFM
8x8
RG-2
VD
8"‘ R
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
VD
VD
8
x
8
S
8x8 SEDH-1 1/2
75 CFM
6x6
EG-2
6"‘ EVD
175 CFM
8x8
RG-2
VD
8"‘ R
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2VD
VD
8
x
8
S
EDH-1 1/2
8x8 S
75 CFM
6x6
EG-2
VD
6"‘ E
175 CFM
8x8
RG-2
VD
8"‘ R
125 CFM
8x6
SG-2
125 CFM
8x6
SG-2
VD
VD
8
x
8
S
EDH-1 1/2
8x8 S
125 CFM
8x6
SG-2
VD
VD
125 CFM
8x6
SG-2
8
x
8
S
EDH-1 1/2 8x8 S
75 CFM
6x6
EG-2
VD
6"‘ E
VD 175 CFM
8x8
RG-2
8"‘ R ACCESS PANEL
VD
8
"‘
E
75 CFM
6x6
EG-2
VD
8
"‘
R175 CFM
8x8
RG-2
1/8" FIRST FLOOR HVAC PLAN
12x8 S
DOWN
24x8
-CONTINUOUS BLOWER OPERATION
300 CFM OUTSIDE AIR FROM HRV-3
700 CFM RETURN AIR
1000 CFM SUPPLY AIR
-CU-2 1/2 ON ROOF
F-2 1/2 FURNACE
-CONTINUOUS BLOWER OPERATION
450 CFM OUTSIDE AIR FROM HRV-3
1050 CFM RETURN AIR
1500 CFM SUPPLY AIR
-CU-4 ON ROOF
F-4 FURNACE
8
x
8
S
8
"
‘
R
1
0
x
1
0
S1
0
x
1
0
R
1
4
x
1
0
S1
2
x
10
R
1
8
x
1
0
S
VD
200 CFM
8"ß NK
SG-1
VD
6
" ‘
S
8"‘ S
200 CFM
8" ‘
RG-1
VD
8"‘ R
300 CFM
10" ‘
RG-1
1
2
x
1
0
R VD
CORRIDOR
8
"
‘
S
12x10 S
100 CFM
12x6
SG-2
12
x
1
0
S
8
" ‘
S
16x8 S 12x8 S
16x16
RG-2
1
6
x
10
R
1
6
x
1
0
S
12x8 R
400 CFM
12x12
RG-2
VD VD
200 CFM
16x6
SG-2
200 CFM
16x6
SG-2
1
4
x
8
S
6"‘ S
75 CFM
6x6
SG-2
VD
F
D
-
B
F
D
-
B
VD
100 CFM
6x6
EG-2
- CONTINUOUS BLOWER OPERATION
650 CFM OUTSIDE AIR FROM HRV-1
950 RETURN AIR
1600 CFM SUPPLY AIR
- CU-4 ON ROOF
F-4 FURNACE
-CONTINUOUS BLOWER OPERATION
200 CFM OUTSIDE AIR FROM HRV-1
600 RETURN AIR
800 CFM SUPPLY AIR
-CU-2 ON ROOF
F-2 FURNACE
1
8
x
10
R
50 CFM
6x6
SG-2
VD
6"‘ E
75 CFM
6x6
EG-2
VD
75 CFM
6x6
EG-2 VD
8"‘ E
1
2
x
1
0
S
14x8 S
EDH-3
1
0
x
8
S
VD
8"‘ S
8"‘ SVD
200 CFM
10x10
EG-2
VD
20x12 S
18x10 R
MT102
3
DOWN
16x10 R
VENTING UP
FURNACE
24x12 DOWN
ELEV. #3
24x10
VD
VD 8"‘ S
VD
8"‘ R
6"‘ E
10x10 S
14x10 S
12x12 E 12x10 E
12x12 R 12x10 R
8x8 E
24x12 DOWN
24x10 DOWN
6"‘ E 8x8 E
A
MA210
TYPICAL 8" HI DUCT
8" ‘ S.
TYPICAL 8" HI DUCT
12x12 E
12x12 R
A
MA210
SECTION
VD
16x10 R
16x10 S
DOOR 1"
UNDERCUT
12x8
8x8 S
125 CFM
8x8
EG-2
2
0
x
1
2
S 1
2
"‘
E
VD
DOWN
12"‘ E
16x10
UP
4"‘ E
DAMPER FOR 200 CFM
VD IN RISE. SET
8" ‘ FA DOWN.
650 CFM
DAMPER FOR
12" ‘ FA. SET
UP
12"‘ E
UP
14"‘ FA
8"‘ S
DOOR 1"
UNDERCUT
8x8 S
12x10 R
UP INSULATE
24x10 FA
12x10 E 12x10
24x10 E
F
D
-
B
14x10 S
12x10 E 10x10 10x8 E
8"‘ E
10x10 R
8x8 S
RETURN AIR SENSOR
RETURN AIR SENSOR
125 CFM
8"ß NK
SG-1
8"‘ E
VD
SENSOR
AIR
RETURN
12x12 E
DOWN
14"‘ FA
8x8 S
10x10 S
8"‘ R
10x10 R12x12 R
16x12 R
SENSOR
RETURN AIR
18x14 R
6"‘ E
IN
S
U
L
A
T
E
1
2
x
1
0
F
A
450 CFM. INSUL.
DAMPER FOR
10x10 FA. SET
INSUL.
300 CFM
DAMPER FOR
10x8 FA. SET
INSULATE
200 CFM.
DAMPER FOR
8"‘ FA. SET
450 CFM. INSULATE
DAMPER FOR
10x10 FA. SET
8
"‘
BELOW
10x10 R
H101
CORRIDOR
SCALE 1/4" = 1’-0"
200 CFM
DAMPER FOR
8" ‘ E. SET
12x10 R
14x12 S
-CONTINUOUS BLOWER OPERATION
150 CFM OUTSIDE AIR FROM HRV-3
450 CFM RETURN AIR
600 CFM SUPPLY AIR
-CU-1 1/2 ON ROOF
F-1 1/2 FURNACE
DOWN
24x12
75 CFM
6x6
EG-2
DOOR 1"
UNDERCUT
8
" ‘
S
VD
VD
VD
UP INSULATE
24x12 FA
UP
24x12 E
24x8 R
RETURN AIR SENSOR
24x12 R DOWN
INSULATE
FOR 150 CFM.
SET DAMPER
8" ‘ FA DOWN.
INSULATE
FOR 450 CFM.
SET DAMPER
10x10 FA DOWN.
16x8 S
24x12 E
INSULATE
FOR 800 CFM.
16x10 FA. SET DAMPER
FLOOR
NEAR
24x8
RG-2
INSUL.
24x12
INSULATE
FOR 300 CFM.
10x8 FA. SET DAMPER
16x10 FA INSULATE
1
4
x
10
S
1
4
x
1
0
S
1
0
x
10
R
1
2
x
1
0
R
1
0
x
1
0
R
1
4
x
8
E
10
x
8
E
8
x
8
E
8
" ‘
E
DOOR 1"
UNDERCUT
Ma
t
c
h
Lin
e
Match Line
- TSTAT OPERATION
700 CFM RETURN AIR
700 CFM SUPPLY AIR
FC-5 FAN COIL
DOWN IN WALL. SPILL ON GRADE
3/4" CONDENSATE PIPING
F
S
D
FSD
FSD
FSD
G108
TRASH
SUN PORCH
G112
700 CFM
36x10
RG-2
1
4
x
1
0
S
1
2
x
10
S
1
0
x
1
0
S
8"‘ S
8"‘ S
8"‘ S
8"‘ S
8"‘ S
8
"‘
S
VD
VD
VD
VD
VD
1
0
x
8
S
10x8 S
140 CFM
14x6
SG-2
140 CFM
14x6
SG-2
140 CFM
14x6
SG-2
140 CFM
14x6
SG-2
140 CFM
14x6
SG-2
65 DEG IN SUMMER
75 DEG IN WINTER
SET FOR:
RETURN AIR SENSORS
NOTE
65 DEG IN SUMMER
75 DEG IN WINTER
SET FOR:
RETURN AIR SENSORS
NOTE
STOR
2
2
x
1
0
S
FD-B
450 CFM
14x14
EG-2
350 CFM
12x12
EG-2
14
x
8
E
1
4
x
1
0
F
A
IN
S
U
L.
1
4
x
1
0
R
F
D
-
B
FD-B
6
"‘
E
6"‘ E
14x12 E
2
4
x
1
2
R
VD
6
"‘
E
24x12 R DOWN
18x10 S
VENTING UP
FURNACE
FURNACE VENTING UP
800 CFM
18x18
RG-2
VD
1
8
x
1
0
R
8"‘ S
24x10 R DOWN
200 CFM
8"‘ NK
SG-1
VD
VD
6
"‘
E
8"‘ E
VD
6
"‘
S
75 CFM
6x6
SG-2
75 CFM
6x6
SG-2
75 CFM
6x6
SG-2
75 CFM
6x6
EG-2
H119
CORRIDOR
H120
TOILET
CLOSET
H118
1
0
" ‘
S
300 CFM
10"ß NK
SG-1
ALL EXHAUSTS
BETWEEN INTAKE AND
- MAINTAIN 10 FOOT MIN
- RUNS CONTINUOUS
850 CFM FA
650 CFM EXH
HRV-1
@ 7’-0" AFF
650 CFM
18x18
LV-1
@ 7’-0" AFF
850 CFM
18x24
LV-1
4"‘ E
LV-1)
(ABOVE
WC-1
12x10 R
8x8 S
14x10 S
18x10 S
14x12 R
16x12 R
22x12 S
22x12 S
RD
RD
SPACE
8"‘ R IN TRUSS
8
x
8
S
8"‘ S BELOW
BELOW
12x8 S
24x10 S
14x10
1
4
x
1
0
E
8
x
8
S
18x10
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
MA
2
1
0
.
d
g
n
9
:
4
3
:
0
8
A
M
8
/
1
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
8
/
1
/
2
0
1
1
MO
D
E
L
:
D
e
f
a
u
l
t
r
j
s
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL
ASSISTED LIVING
T
T
T
TTTTTTTTT
T
TTT
T
TT
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T