HomeMy WebLinkAbout029 MA210.pdfMA210 RJS 12x8 S VENTING UP FURNACE 24x8 DOWN -CONTINUOUS BLOWER OPERATION 150 CFM OUTSIDE AIR 450 CFM RETURN AIR 600 CFM SUPPLY AIR -CU-1 1/2 ON ROOF F-1 1/2 FURNACE WC-3 16 x 8 S 16x8 R 8 "‘ E WC-4 DOOR 1" UNDERCUT 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-18"‘ S VDVD VD VD VD 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 200 CFM 8"ß NK SG-1 10x6 S10x10 S VD VD VD VD 200 CFM 16x6 SG-2 200 CFM 16x6 SG-2 150 CFM 14x6 SG-2 200 CFM 16x6 SG-2 175 CFM 16x6 SG-2 175 CFM 16x6 SG-2 VD VD 1 0 x 6 S VD 175 CFM 16x6 SG-2 175 CFM 16x6 SG-2 10x10 S 1 8 x 1 0 S 2 2 x 1 0 S 22x10 S 24x10 S VD VD VD VD 10"ß S 10"ß S 10"ß R 1 0 "ß R VD 1 8 x 1 0 R 1 2 x 8 E 8 "‘ E VD VD 12x10 S 1 2 x 1 0 S DBU-2 FD-B DBU-2 12x10 R 150 CFM 14x6 SG-2 8"‘ S VD VD 16x10 S16x10 S 12x10 S 225 CFM EA 8"ß NK (2) RG-1 VD VD 8x8 S 8 x 8 S 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 175 CFM 8x8 RG-2VD VD 75 CFM 6x6 EG-2 -CONTINUOUS BLOWER OPERATION 300 CFM OUTSIDE AIR FROM HRV-2 700 CFM RETURN AIR 1000 CFM SUPPLY AIR -CU-2 1/2 ON ROOF F-2 1/2 FURNACE PANEL ACCESS -CONTINUOUS BLOWER OPERATION 450 CFM OUTSIDE AIR FROM HRV-2 1050 CFM RETURN AIR 1500 CFM SUPPLY AIR -CU-4 ON ROOF F-4 FURNACE -CONTINUOUS BLOWER OPERATION 200 CFM OUTSIDE AIR FROM HRV-2 400 CFM RETURN AIR 600 CFM SUPPLY AIR -CU-1 1/2 ON ROOF F-1 1/2 FURNACE -CONTINUOUS BLOWER OPERATION 800 CFM OUTSIDE AIR FROM HRV-3 800 RETURN AIR 1600 CFM SUPPLY AIR -CU-4 ON ROOF F-4 FURNACE -CONTINUOUS BLOWER OPERATION 450 CFM OUTSIDE AIR FROM HRV-2 1050 CFM RETURN AIR 1500 CFM SUPPLY AIR -CU-4 ON ROOF F-4VAV FURNACE 300 CFM 10"ß NK SG-1A 300 CFM 10"ß NK SG-1A 200 CFM 12x8 SG-2 200 CFM 12x8 SG-2 200 CFM 12x8 SG-2 300 CFM 12x10 RG-2 300 CFM 12x10 RG-2 EDH-1 1/2 EDH-1 1/2 EDH-1 1/2EDH-1 1/2EDH-1 1/2EDH-1 1/2EDH-1 1/2EDH-1 1/2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 8x8 S 8x8 S 8x8 S8x8 S 8x8 S 8x8 S 8x8 S8x8 S8x8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S VD VD VD VD VD VD VD VD VD VD VD VD VD VDVD VDVD VD 75 CFM 6x6 EG-2 8"‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD75 CFM 6x6 EG-2 6"‘ E VD 75 CFM 6x6 EG-2 6"‘ E VD 6"‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD75 CFM 6x6 EG-2 6 "‘ E VD 75 CFM 6x6 EG-2 VD 8"‘ OA INSULATE 75 CFM 6x6 EG-2 175 CFM 8x8 RG-2 8"‘ R VD 175 CFM 8x8 RG-2 8"‘ R VD 175 CFM 8x8 RG-2 VD 175 CFM 8x8 RG-2 8"‘ R VD 175 CFM 8x8 RG-2 8"‘ R VD 175 CFM 8x8 RG-2 VD 175 CFM 8x8 RG-2 8"‘ R VD 175 CFM 8x8 RG-2 VD 175 CFM 8x8 RG-2 8"‘ RVD G109 ACTIVITY LIVING G110 DINING H102 EQUIPMENT ELEVATOR G104 STORAGE GENERAL G105 COORDINATOR PROGRAM G103 OFFICE ATTENDANT G102 #4 ELEV. ELEC. H116 LAUNDRY H114 LINEN H115 H110 FOYER MECH. H113 SPA H111 H109 TOILET H101 CORRIDOR PANTRY SERVING H103 H104 TOILET H108 TV ROOM UNIT A 1711 1708 UNIT A STAIR ’G’ 1709 UNIT A 1707 UNIT A 1706 UNIT A 1704 UNIT D 1702 UNIT E 1705 UNIT A 1703 UNIT A 1701 UNIT A 1801 UNIT A UNIT A 1803 1805 UNIT B 1807 UNIT F 1809 UNIT A UNIT C 1802 1804 UNIT G 1806 UNIT C 1808 UNIT A 1810 UNIT A 1812 UNIT A H106 HSKP 1811 UNIT A 1813 UNIT A 1815 UNIT E 1817 UNIT D 1819 UNIT A STAIR ’H’ H107 MECH H105 MECH H117 MECH BY OTHERS TO FLOOR DRAIN. FLOOR DRAIN 3/4" CONDENSATE DOWN IN WALL BY OTHERS TO FLOOR DRAIN. FLOOR DRAIN 3/4" CONDENSATE DOWN IN WALL SOILED ENTRY MECH H112 H100 G101 G106 G111 MECH G107 12x10 75 CFM 6x6 EG-2 VD 6 "‘ E CONTINUOUS RUNS 125 CFM EF-7 175 CFM 8x8 RG-2 VD 8 "‘ R 6 "‘ E VD 75 CFM 6x6 EG-2 EDH-1 1/2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 VD VD VD VDVD VD VD VD VD VD VD VD 8x8 S8x8 S8x8 S 8x8 S 8x8 S 8x8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S 8 x 8 S EDH-1 1/2EDH-1 1/2 EDH-1 1/2 EDH-1 1/2 EDH-1 1/2 6 "‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD 75 CFM 6x6 EG-2 6 "‘ E VD 75 CFM 6x6 EG-2 175 CFM 8x8 RG-2 VD 8 "‘ R 175 CFM 8x8 RG-2VD 8 "‘ R 175 CFM 8x8 RG-2 VD 8 "‘ R 175 CFM 8x8 RG-2 VD 8"‘ R 175 CFM 8x8 RG-2 VD 8 "‘ R EDH-2 UP 24x10 E 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 8x8 S 8 x 8 S VD VD 75 CFM 6x6 EG-2 6"‘ EVD 175 CFM 8x8 RG-2 8 "‘ R VD EDH-2 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 VD VD 8 x 8 S 8x8 S 175 CFM 8x8 RG-2 8"‘ R VD 75 CFM 6x6 EG-2 6"‘ E VD 125 CFM 8x6 SG-2 8 x 8 S 125 CFM 8x6 SG-2 VD VD 8x8 SEDH-1 1/2 175 CFM 8x8 RG-2VD 8"‘ R 75 CFM 6x6 EG-2 VD 6"‘ E 125 CFM 8x6 SG-2VD VD 8 x 8 S 125 CFM 8x6 SG-2 EDH-1 1/2 8x8 S 75 CFM 6x6 EG-2 VD 6"‘ E 175 CFM 8x8 RG-2 VD 8"‘ R EDH-2 125 CFM 8x6 SG-2 VD VD125 CFM 8x6 SG-2 8 x 8 S 8x8 S EDH-1 1/2 75 CFM 6x6 EG-2VD 6"‘ E 175 CFM 8x8 RG-2 VD 8"‘ R 125 CFM 8x6 SG-2 VD VD 125 CFM 8x6 SG-2 8 x 8 S 8x8 S EDH-1 1/2 75 CFM 6x6 EG-2VD6"‘ E 175 CFM 8x8 RG-2 VD 8"‘ R 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 VD VD 8 x 8 S 8x8 SEDH-1 1/2 75 CFM 6x6 EG-2 6"‘ EVD 175 CFM 8x8 RG-2 VD 8"‘ R 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2VD VD 8 x 8 S EDH-1 1/2 8x8 S 75 CFM 6x6 EG-2 VD 6"‘ E 175 CFM 8x8 RG-2 VD 8"‘ R 125 CFM 8x6 SG-2 125 CFM 8x6 SG-2 VD VD 8 x 8 S EDH-1 1/2 8x8 S 125 CFM 8x6 SG-2 VD VD 125 CFM 8x6 SG-2 8 x 8 S EDH-1 1/2 8x8 S 75 CFM 6x6 EG-2 VD 6"‘ E VD 175 CFM 8x8 RG-2 8"‘ R ACCESS PANEL VD 8 "‘ E 75 CFM 6x6 EG-2 VD 8 "‘ R175 CFM 8x8 RG-2 1/8" FIRST FLOOR HVAC PLAN 12x8 S DOWN 24x8 -CONTINUOUS BLOWER OPERATION 300 CFM OUTSIDE AIR FROM HRV-3 700 CFM RETURN AIR 1000 CFM SUPPLY AIR -CU-2 1/2 ON ROOF F-2 1/2 FURNACE -CONTINUOUS BLOWER OPERATION 450 CFM OUTSIDE AIR FROM HRV-3 1050 CFM RETURN AIR 1500 CFM SUPPLY AIR -CU-4 ON ROOF F-4 FURNACE 8 x 8 S 8 " ‘ R 1 0 x 1 0 S1 0 x 1 0 R 1 4 x 1 0 S1 2 x 10 R 1 8 x 1 0 S VD 200 CFM 8"ß NK SG-1 VD 6 " ‘ S 8"‘ S 200 CFM 8" ‘ RG-1 VD 8"‘ R 300 CFM 10" ‘ RG-1 1 2 x 1 0 R VD CORRIDOR 8 " ‘ S 12x10 S 100 CFM 12x6 SG-2 12 x 1 0 S 8 " ‘ S 16x8 S 12x8 S 16x16 RG-2 1 6 x 10 R 1 6 x 1 0 S 12x8 R 400 CFM 12x12 RG-2 VD VD 200 CFM 16x6 SG-2 200 CFM 16x6 SG-2 1 4 x 8 S 6"‘ S 75 CFM 6x6 SG-2 VD F D - B F D - B VD 100 CFM 6x6 EG-2 - CONTINUOUS BLOWER OPERATION 650 CFM OUTSIDE AIR FROM HRV-1 950 RETURN AIR 1600 CFM SUPPLY AIR - CU-4 ON ROOF F-4 FURNACE -CONTINUOUS BLOWER OPERATION 200 CFM OUTSIDE AIR FROM HRV-1 600 RETURN AIR 800 CFM SUPPLY AIR -CU-2 ON ROOF F-2 FURNACE 1 8 x 10 R 50 CFM 6x6 SG-2 VD 6"‘ E 75 CFM 6x6 EG-2 VD 75 CFM 6x6 EG-2 VD 8"‘ E 1 2 x 1 0 S 14x8 S EDH-3 1 0 x 8 S VD 8"‘ S 8"‘ SVD 200 CFM 10x10 EG-2 VD 20x12 S 18x10 R MT102 3 DOWN 16x10 R VENTING UP FURNACE 24x12 DOWN ELEV. #3 24x10 VD VD 8"‘ S VD 8"‘ R 6"‘ E 10x10 S 14x10 S 12x12 E 12x10 E 12x12 R 12x10 R 8x8 E 24x12 DOWN 24x10 DOWN 6"‘ E 8x8 E A MA210 TYPICAL 8" HI DUCT 8" ‘ S. TYPICAL 8" HI DUCT 12x12 E 12x12 R A MA210 SECTION VD 16x10 R 16x10 S DOOR 1" UNDERCUT 12x8 8x8 S 125 CFM 8x8 EG-2 2 0 x 1 2 S 1 2 "‘ E VD DOWN 12"‘ E 16x10 UP 4"‘ E DAMPER FOR 200 CFM VD IN RISE. SET 8" ‘ FA DOWN. 650 CFM DAMPER FOR 12" ‘ FA. SET UP 12"‘ E UP 14"‘ FA 8"‘ S DOOR 1" UNDERCUT 8x8 S 12x10 R UP INSULATE 24x10 FA 12x10 E 12x10 24x10 E F D - B 14x10 S 12x10 E 10x10 10x8 E 8"‘ E 10x10 R 8x8 S RETURN AIR SENSOR RETURN AIR SENSOR 125 CFM 8"ß NK SG-1 8"‘ E VD SENSOR AIR RETURN 12x12 E DOWN 14"‘ FA 8x8 S 10x10 S 8"‘ R 10x10 R12x12 R 16x12 R SENSOR RETURN AIR 18x14 R 6"‘ E IN S U L A T E 1 2 x 1 0 F A 450 CFM. INSUL. DAMPER FOR 10x10 FA. SET INSUL. 300 CFM DAMPER FOR 10x8 FA. SET INSULATE 200 CFM. DAMPER FOR 8"‘ FA. SET 450 CFM. INSULATE DAMPER FOR 10x10 FA. SET 8 "‘ BELOW 10x10 R H101 CORRIDOR SCALE 1/4" = 1’-0" 200 CFM DAMPER FOR 8" ‘ E. SET 12x10 R 14x12 S -CONTINUOUS BLOWER OPERATION 150 CFM OUTSIDE AIR FROM HRV-3 450 CFM RETURN AIR 600 CFM SUPPLY AIR -CU-1 1/2 ON ROOF F-1 1/2 FURNACE DOWN 24x12 75 CFM 6x6 EG-2 DOOR 1" UNDERCUT 8 " ‘ S VD VD VD UP INSULATE 24x12 FA UP 24x12 E 24x8 R RETURN AIR SENSOR 24x12 R DOWN INSULATE FOR 150 CFM. SET DAMPER 8" ‘ FA DOWN. INSULATE FOR 450 CFM. SET DAMPER 10x10 FA DOWN. 16x8 S 24x12 E INSULATE FOR 800 CFM. 16x10 FA. SET DAMPER FLOOR NEAR 24x8 RG-2 INSUL. 24x12 INSULATE FOR 300 CFM. 10x8 FA. SET DAMPER 16x10 FA INSULATE 1 4 x 10 S 1 4 x 1 0 S 1 0 x 10 R 1 2 x 1 0 R 1 0 x 1 0 R 1 4 x 8 E 10 x 8 E 8 x 8 E 8 " ‘ E DOOR 1" UNDERCUT Ma t c h Lin e Match Line - TSTAT OPERATION 700 CFM RETURN AIR 700 CFM SUPPLY AIR FC-5 FAN COIL DOWN IN WALL. SPILL ON GRADE 3/4" CONDENSATE PIPING F S D FSD FSD FSD G108 TRASH SUN PORCH G112 700 CFM 36x10 RG-2 1 4 x 1 0 S 1 2 x 10 S 1 0 x 1 0 S 8"‘ S 8"‘ S 8"‘ S 8"‘ S 8"‘ S 8 "‘ S VD VD VD VD VD 1 0 x 8 S 10x8 S 140 CFM 14x6 SG-2 140 CFM 14x6 SG-2 140 CFM 14x6 SG-2 140 CFM 14x6 SG-2 140 CFM 14x6 SG-2 65 DEG IN SUMMER 75 DEG IN WINTER SET FOR: RETURN AIR SENSORS NOTE 65 DEG IN SUMMER 75 DEG IN WINTER SET FOR: RETURN AIR SENSORS NOTE STOR 2 2 x 1 0 S FD-B 450 CFM 14x14 EG-2 350 CFM 12x12 EG-2 14 x 8 E 1 4 x 1 0 F A IN S U L. 1 4 x 1 0 R F D - B FD-B 6 "‘ E 6"‘ E 14x12 E 2 4 x 1 2 R VD 6 "‘ E 24x12 R DOWN 18x10 S VENTING UP FURNACE FURNACE VENTING UP 800 CFM 18x18 RG-2 VD 1 8 x 1 0 R 8"‘ S 24x10 R DOWN 200 CFM 8"‘ NK SG-1 VD VD 6 "‘ E 8"‘ E VD 6 "‘ S 75 CFM 6x6 SG-2 75 CFM 6x6 SG-2 75 CFM 6x6 SG-2 75 CFM 6x6 EG-2 H119 CORRIDOR H120 TOILET CLOSET H118 1 0 " ‘ S 300 CFM 10"ß NK SG-1 ALL EXHAUSTS BETWEEN INTAKE AND - MAINTAIN 10 FOOT MIN - RUNS CONTINUOUS 850 CFM FA 650 CFM EXH HRV-1 @ 7’-0" AFF 650 CFM 18x18 LV-1 @ 7’-0" AFF 850 CFM 18x24 LV-1 4"‘ E LV-1) (ABOVE WC-1 12x10 R 8x8 S 14x10 S 18x10 S 14x12 R 16x12 R 22x12 S 22x12 S RD RD SPACE 8"‘ R IN TRUSS 8 x 8 S 8"‘ S BELOW BELOW 12x8 S 24x10 S 14x10 1 4 x 1 0 E 8 x 8 S 18x10 REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l C F G H J K A B D E L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ MA 2 1 0 . d g n 9 : 4 3 : 0 8 A M 8 / 1 / 2 0 1 1 P L O T T E D O N : 8 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 8 / 1 / 2 0 1 1 MO D E L : D e f a u l t r j s B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL ASSISTED LIVING T T T TTTTTTTTT T TTT T TT T T T T T T T T T T T T T T T T T