HomeMy WebLinkAbout029 PC202.pdfG
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
In
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
C F
G
H
J
K
A
B
D
E
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
M
w
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
P
C
2
0
2
.
d
g
n
6
:
3
6
:
4
4
P
M
7
/
3
0
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
8
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
7
/
3
0
/
2
0
1
1
MO
D
E
L
:
U
n
t
i
t
l
e
d
S
h
e
e
t
j
a
w
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:
D
R
A
W
I
N
G
L
I
M
I
T
L
I
N
E
01 AUG 2011
FAX
TEL
COMMONS
GENERAL PLUMBING NOTES
STACK OF UNITS. PROVIDE VENTED REGULATOR AND SHUT-OFF AT EACH UNIT.
- GAS TO HVAC UNITS TO BE SUPPLED FROM ABOVE. EXTEND 3/4" (2 PSI) RISER UP TO EACH
TO FREEZING..
- WATER PIPING SHALL NOT BE LOCATED IN EXTERIOR WALLS, ATTIC OR ANY SPACE SUBJECT
IN DROPPED CEILING SPACES.
SPACE WITH APPROPRIATE FIRESTOPPING APPLIED. DUCTWORK TO HAVE SPACE PRIORITY
AS MUCH AS POSSIBLE. WHERE NECESSARY, PENETRATE UP OR DOWN INTO FLOOR TRUSS.
- WATER PIPING SHOWN WITHIN TYPICAL UNITS TO BE LOCATED IN DROPPED CEILING SPACE
- 3 HOUR RATING EXISTS BETWEEN RESIDENTIAL AND GARAGE.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS AND ROOF OR COMMONS.
- 1 HOUR RATING EXISTS BETWEEN RESIDENTIAL FLOORS.
FOR WALL TYPES AND EXACT LOCATIONS OF RATED CONSTRUCTION.
TO MAINTAIN THE RATING OF THE CONSTRUCTION. REFER TO ARCHITECTURAL PLANS
PIPING (GROUTED TIGHT) OR SEALED WITH A U.L. APPROVED FIRE BARRIER SYSTEM
- ANY PENETRATION OF THE FIRE RATED CONSTRUCTION MUST BE MADE WITH METAL
CEILING SPACES.
JOIST SPACE WHERE POSSIBLE. DUCTWORK TO HAVE SPACE PRIORITY IN DROPPED
- LOCATE ABOVE GRADE DRAIN, VENT AND WATER DISTRIBUTION PIPING WITHIN CEILING
LAYOUTS WITHIN APARTMENT UNITS.
- REFER TO 1/4" TYPICAL UNIT PLUMBING PLANS FOR FIXTURE DESIGNATIONS AND PIPING
1/8" PARTIAL FOUNDATION LEVEL PLUMBING PLAN PC202
TJL/JAW
R
E
F
E
R
T
O
P
C
2
0
0
M
A
T
C
H
L
IN
E
REFER TO PC201
MATCH LINE
M A T C H L I N E REFER T O P S 2 0 0
FD-1
FD-3
FD-3
FD-3
FD-1
FD-1FD-1
C.O.
C.O.
8" SAN.
2" W. DN.
2" W. DN.
2" V. UP
3"
2"
2" V. UP
2" V. UP
2" V. UP
4"4"4"
2" W. DN.
2" W. DN.
2" W. DN.
2" W. DN.
2"
1 1/2" V. UP
2" W. DN.
2" V. UP
8" SAN.
2" V. UP
2" W. DN.
2" V. UP
1 1/2" V. UP
2" W. DN.
4" SAN.4" SAN.
2"
3"
4"
4"4"
2"
4"
2"
2"
8" SAN.
1 1/2" V. UP
(205 S.F.)
4" COND. DN.
(561 S.F.)
4" COND. DN.
(255 S.F.)
4" COND. DN.
(562 S.F.)
4" COND. DN.
(1,532 S.F.)
4" COND. DN.
(1,152 S.F.)
4" COND. DN.
(562 S.F.)
4" STM.
C.O.
(2,094 S.F.)
4" STM.C.O.
(3,246 S.F.)
6" STM.
(1,834 S.F.)
4" COND. DN.
2" W. DN.
2" V. UP
PT101
2
GT-1
(2,420 S.F.)
4" COND. DN.
(2,420 S.F.)
4" STM.
(561 S.F.)
4" STM.
3" SAN.
PLUMBING PLAN
FOR 1/4" KITCHEN
REFER TO PK200
4" G.W.
4" SAN.
4" STM.
4"
4"
(UNDERGROUND)
6" GAS @ 2 PSI
(UNDERGROUND)
8" CW
8" CW UP
6" GAS UP
CORRIDOR
CORRIDOR
JANITOR
WOMEN
MEN
DINING
TOILET
TOILET
SALON
STORAGE
CENTRAL
ELECTRICAL
WATER SERVICE
MECHANICAL &
STORAGE
HSKPG.
DIRECTOR
HSKPG.
ROOM
CONFERENCE
A.L. MARKETING
VESTIBULE
WAITING
LOBBY
CLERICAL
RECEPTION
WORK ROOM
KITCHEN
SERVING
ROOM
BREAK
SERVICES
SOCIAL
CORRIDOR
WASHING
DRYING
C27
C28
C25
C47
C46
C45
C44
C32
C33
C34
C30
C29
C43
C42
C41
C40
C37
C35 C36
C39
C38
CORRIDOR
AL14
AL13
AL12
AL15
AL16
AL10 AL9
AL7
AL6
AL4
AL17
CORRIDOR
AL3
AL2
AL1
AL19AL18
AL20
FILES
COORDINATOR
LIFESTYLE
MAINTENANCE
AL11
DRYING
C31
AL5
DINING
PRIVATE
AL21
CORRIDOR
KITCHEN
C26
AL8
DIRECTOR
MEDICAL
DIRECTOR
A.L.
JANITOR
C70 C.O.
(797 S.F.)
3" STM.
(647 S.F.)
3" STM.
(647 S.F.)
D.S.
(400 S.F.)
D.S.
(400 S.F.)
3" STM.
(797 S.F.)
4" STM.
AD-1
(741 S.F.)
D.S.
(741 S.F.)
3" STM.
(267 S.F.)
D.S.
(267 S.F.)
3" STM.
(105 S.F.)
D.S.
(105 S.F.)
3" STM.
(1,760 S.F.)
D.S.
(1,760 S.F.)
4 STM.
(670 S.F.)
4 STM.
(1,444 S.F.)
4" STM.
(670 S.F.)
D.S.
(205 S.F.)
4" STM.
C.O.
(3,415 S.F.)
6" STM.
(2,132 S.F.)
4" STM.
(2,114 S.F.)
4" STM.
(5,529 S.F.)
8" STM.
(799 S.F.)
4" COND. DN.
(799 S.F.)
4" STM.
(17,843 S.F.)
10" STM.
(6,954 S.F.)
6" STM.
(9,069 S.F.)
8" STM.
(1,874 S.F.)
6" STM.
(16,023 S.F.)
10" STM.C.O.
(267 S.F.)
D.S.
(267 S.F.)
3" STM.
(1,008 S.F.)
3" STM.
(2,753 S.F.)
6" S.F.
(196 S.F.)
D.S.
(196 S.F.)
3" STM.
(3,748 S.F.)
6" S.F.
(24,929 S.F.)
10" STM.
(564 S.F.)
D.S.
(564 S.F.)
3" STM.
(412 S.F.)
D.S.
(1,227 S.F.)
D.S.
(1,227 S.F.)
4" STM.
(1,639 S.F.)
4" STM.
(482 S.F.)
D.S.
(653 S.F.)
D.S.
(653 S.F.)
3" STM.
(482 S.F.)
6" STM.
(2,774 S.F.)
6" STM.
(3,338 S.F.)
6" STM.
(245 S.F.)
D.S.
CHEF
EXECUTIVE
CARTS
TRASH
STORAGE
DRY
ROOM/IT
SERVER
DIRECTOR
OPERATIONS
2"
1 1/2" V. UP
HUB DRAIN
2" OPEN
PT101
4
I.E.=97’-0"
C.O.
I.E.=99’-0"
(797 S.F.)
D.S.
I.E.=98’-0"
C.O.
2"
I.E.=97’-10"
C.O.