HomeMy WebLinkAbout030 EI303.pdfEI303 TJL/TAR 1/4" ELECTRICAL UNIT PLANS G H 30A - 2P COMBINATION UNIT WASHER / DRYER 20 AMP - 1P REFRIGERATOR 40 AMP - 2P RANGEB C D E A NOTES FOR THIS SHEET ONLY J K L NOTE: TO THE LISTING INSTALLATION INSTRUCTIONS. THEIR MANUFACTURER AND SECURED ACCORDING (PADDLE) FAN LISTED, SHALL BE MARKED BY ALL AREA PERIMETER WALLS SHALL BE CEILING IN DWELLING UNITS TWO FEET OR MORE FROM CEILING MOUNTED LIGHTING OUTLET BOXES INSTALLATION - TYPICAL FOR ALL UNITS. AVOID CONFLICT WITH THE MEDICINE CABINET INTERIOR ELEVATION DRAWINGS SO AS TO TO BE DETERMINED PER ARCHITECTURAL OF BATHROOM SWITCHES AND OUTLETS ARE THE HORIZONTAL AND VERTICAL POSITION NOTE: TENANT TO PROVIDE FIXTURE FAN SUPPORT TO BE CENTERED IN ROOM. SWITCHED JUNCTION BOX FOR PADDLE TENANT TO PROVIDE FIXTURE SWITCHED JUNCTION BOX. M 20 AMP - 1P FOR WASTE DISPOSAL SWITCHED OUTLET BELOW SINK ’ADA’ UNIT NOTES - AUDIO/VISUAL FIRE ALARM DEVICE BATH FIRE ALARM DEVICE FIRE ALARM SYSTEM TO PROVIDE POWER TO VIBRATING PAD - DUPLEX RECEPTACLE NEAR BED LOCATION TIED INTO - VISUAL ALARM - SMOKE DETECTOR W/SYSTEM PROGRAMMABLE SOUNDER BASE BEDROOM - DOOR BELL W/ INDICATOR LIGHT LIVING ROOM OR HALL AREA OF BEDROOM - AUDIO/VISUAL FIRE ALARM DEVICE LIVING ROOM TO BE DESIGNATED FOR USE BY THE PHYSICALLY DISABLED IN ADDITION TO TYPICAL UNIT NOTES AT THOSE UNITS NOTE: NEC ART. 210.12 (B) ARC FAULT INTERUPTER PROTECTED PER LIVING, DINING, DEN, HALLWAYS, ETC. TO BE REMAINING RECEPTACLES IN BEDROOMS, PROTECTED PER NEC ART. 210.8 (A) TO BE GROUND FAULT INTERUPTER (GFI) RECEPTACLES IN KITCHEN AND BATHS SWITCH DISCONNECT W/ UNDERCABINET 20 AMP - 1P DISHWASHER E WIRED BY ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED BY OTHERS 20 AMP - 1P 120V - 1‘ - 2.5 AMP RANGEHOOD W/ LIGHT SUPPLIED AND INSTALLED BY OTHERS IN SELF SPACE - UNIT IS PROVIDE OUTLET BEHIND UNIT 20 AMP - 1P 120V - 1‘ - 1100 WATTS MICROWAVE OVEN BY DIV. 16 PROVIDED AND INSTALLED BY DIV. 15 AND WIRED 20AMP - 1P CIRCUIT - GFI 120V - 1‘ - .75AMP (FAN) - 250 WATT (HEAT LAMP) HF-1 EXHAUST FAN/HEATER 30 AMP - 2P CIRCUIT 208V - 1‘ - MCA=21.2 AMPS MAGIC PAK HVAC UNIT HC-2 1/2 S DC AFI HVAC BD GFI-WP S3 J J L RG 3 - 0 RE-3GFI K SHOWER S S S T K CS H G M AFI AFI C2 OUTLET ONLY SWITCH TOP BEDROOM S S OUTLET ONLY SWITCH TOP W.I.C. BEDROOM LIVING ROOM ENTRY BATH P & SH P & S H 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 2.2DLX KITCHEN C E B CW AFI SS D A S F RD RC GFI GFI GFIAC GFI GFI RD GFI PATIO P & S H P & SH P & SH AFI GFI RE-2 CS 3-0 S S ST C2 AFI AFI RF S SS AFI AFI AFI AFI AFI AFI RF RA RB AFI AFI J AFI C2 C2 C2C2 S S 3 S 3 S3 S3 S3 S D OUTLET ONLY SWITCH TOP S CA AFI GFI DINING S PSB S PSB S PSB S PSB ENTRY S 3 RA W.I.C. P & SH P & S H P & S H RG AFI GFI S J - TYPICAL AT 48" A.F.F. CABLE CONNECTORS FOR TELEVISION / TELEPHONE RECESSED JUNCTION BOX W/ COVER 2.2 DELUXE ’B’ AREA = 1380 SQFT UNITS 1309 AREA = 1280 SQFT 2.2 DELUXE ’A’ UNITS 1105, 1113, 1309 (SIMILAR) S REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ E I 3 0 3 . d g n 3 : 4 1 : 4 4 P M 7 / 3 1 / 2 0 1 1 P L O T T E D O N : 4 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 7 / 2 6 / 2 0 1 1 MO D E L : D e f a u l t t a r B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL