HomeMy WebLinkAbout032 EI305.pdfEI305
DINING
BATH
GREAT ROOM
BEDROOM
MASTER
PATIO
PATIO
GREAT ROOM
BEDROOM
MASTER
W.I.C.
STUDY
1/4" UNIT ELECTRICAL PLANS
TJL/TAR
AREA = 1615 SQFT
UNITS
1.1 TRADITIONAL & 1.1 DELUXE
UNITS
AREA = 1515 SQFT
1.1 TRADITIONAL & 1.1 TRADITIONAL
ENTRY
S
SHOWER
3-0
S
T
S
S
C2
S
S3
DA
RA
RE-3
BEDROOM
C2
SPSB
S
C2
RF
RG
S
C2
J
SPSB
OUTLET ONLY
SWITCH TOP
1‘ - 3 WIRE
100 AMP - 2P - 120/208V
LOADCENTER PANEL 1.1DLX
J
K
M
J
G
P & SH
GFI-WP
AFI
HVAC
BD
5
S
H
HLF-1
CS
GFI
EDGE-TYPICAL
TUB/SHOWER
FROM HLF-1 &
3’ CLEARANCE
NOTE:
GFI
GFI
AC
AFI
GFI
AFI
AFI
AFI AFI
AFI
AFI
AFI
SHOWER
KITCHEN
BEDROOM
W.I.C.
PATIO
P & SH
5 SH
HVAC
BD
HLF-1
CS
GFI-WP
GFI
GFI
GFI
C
E
B
CW
3-0
GFI
AC
C2
C2
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
EDGE-TYPICAL
TUB/SHOWER
FROM HLF-1 &
3’ CLEARANCE
NOTE:
S PSB
H
S
S
T
S
S S
D
A
S
S PSB
S
3
CA
S
S
GFI
S
AFI
S
F
S
C2
RC
RE-3
RF
RG
RD RD
DA
OUTLET ONLY
SWITCH TOP
OUTLET ONLY
SWITCH TOP
1‘ - 3 WIRE
100 AMP - 2P - 120/208V
LOADCENTER PANEL 1.1TRD
AFI
K
M
GFI
J
BEDROOM
W.I.C.
PATIO
ENTRY
3-0
C2
C2
SPSB
H
J
S
S
T
S
S
S
SPSB
S
3
CA
S3
S
S
S
S
C2
S3
RA
RE-3
RF
RG
DA
OUTLET ONLY
SWITCH TOP
1‘ - 3 WIRE
100 AMP - 2P - 120/208V
LOADCENTER PANEL 1.1TRD
J
K
M
J
G
P & SH
5 SH
HVAC
BD
HLF-1CS
GFI-WP
GFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
EDGE-TYPICAL
TUB/SHOWER
FROM HLF-1 &
3’ CLEARANCE
NOTE:
AFI
AFI
SHOWER
KITCHEN
W.I.C.
PATIO
P & SH
HVAC
BD
HLF-1
CS
GFI-WP
GFI
GFI
GFIGFI
C
E
B
3-0
GFI
AC
C2
C2
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
S PSB
J
J
S
T
S
S S
D
A
S
S
S PSB
S
3
CA
S
S
S
AFI
S
F
S
C2
S
D
RA
RC
RE-3
RF
RG
RD RD
DA
OUTLET ONLY
SWITCH TOPOUTLET ONLY
SWITCH ONE
1‘ - 3 WIRE
100 AMP - 2P - 120/208V
LOADCENTER PANEL 1.1TRD
AFI
J
K
L
M
GFI
CA
EDGE-TYPICAL
& TUB/SHOWER
FROM HLF-1 / CA
3’ CLEARANCE
NOTE:
S
S3
AFI AFI
AFIAFI
J
J
S
AFI
CA
S
S
3
C2
C2
H
30A - 2P
COMBINATION UNIT
WASHER / DRYER
20 AMP - 1P
REFRIGERATOR
40 AMP - 2P
RANGEB
C
D
E
A
NOTES FOR THIS SHEET ONLY
J
K
L
NOTE:
INSTALLATION - TYPICAL FOR ALL UNITS.
AVOID CONFLICT WITH THE MEDICINE CABINET
INTERIOR ELEVATION DRAWINGS SO AS TO
TO BE DETERMINED PER ARCHITECTURAL
OF BATHROOM SWITCHES AND OUTLETS ARE
THE HORIZONTAL AND VERTICAL POSITION
NOTE:
TENANT TO PROVIDE FIXTURE
FAN SUPPORT TO BE CENTERED IN ROOM.
SWITCHED JUNCTION BOX FOR PADDLE
M
20 AMP - 1P
FOR WASTE DISPOSAL
SWITCHED OUTLET BELOW SINK
’ADA’ UNIT NOTES
- AUDIO/VISUAL FIRE ALARM DEVICE
BATH
FIRE ALARM DEVICE
FIRE ALARM SYSTEM TO PROVIDE POWER TO VIBRATING PAD
- DUPLEX RECEPTACLE NEAR BED LOCATION TIED INTO
- VISUAL ALARM
- SMOKE DETECTOR W/SYSTEM PROGRAMMABLE SOUNDER BASE
BEDROOM
- DOOR BELL W/ INDICATOR LIGHT
LIVING ROOM OR HALL AREA OF BEDROOM
- AUDIO/VISUAL FIRE ALARM DEVICE
LIVING ROOM
TO BE DESIGNATED FOR USE BY THE PHYSICALLY DISABLED
IN ADDITION TO TYPICAL UNIT NOTES AT THOSE UNITS
NOTE:
NEC ART. 210.12 (B)
ARC FAULT INTERUPTER PROTECTED PER
LIVING, DINING, DEN, HALLWAYS, ETC. TO BE
REMAINING RECEPTACLES IN BEDROOMS,
PROTECTED PER NEC ART. 210.8 (A)
TO BE GROUND FAULT INTERUPTER (GFI)
RECEPTACLES IN KITCHEN AND BATHS
SWITCH DISCONNECT
W/ UNDERCABINET
20 AMP - 1P
DISHWASHER
WIRED BY ELECTRICAL CONTRACTOR
SUPPLIED AND INSTALLED BY OTHERS
20 AMP - 1P
120V - 1‘ - 2.5 AMP
RANGEHOOD W/ LIGHT
SUPPLIED AND INSTALLED BY OTHERS
IN SELF SPACE - UNIT IS
PROVIDE OUTLET BEHIND UNIT
20 AMP - 1P
120V - 1‘ - 1100 WATTS
MICROWAVE OVEN
BY DIV. 16
PROVIDED AND INSTALLED BY DIV. 15 AND WIRED
20AMP - 1P CIRCUIT - GFI
120V - 1‘ - .75AMP (FAN) - 250 WATT (HEAT LAMP)
HF-1 EXHAUST FAN/HEATER
20 AMP - 2P CIRCUIT
208V - 1‘ - MCA=14.1 AMPS
MAGIC PAK HVAC UNIT HC-1 1/2
N
25 AMP - 2P CIRCUIT
208V - 1‘ - MCA=17.5 AMPS
MAGIC PAK HVAC UNIT HC-2F
TENANT TO PROVIDE FIXTURE
SWITCHED JUNCTION BOX.
P
AND WIRED BY DIV. 16
PROVIDED AND INSTALLED BY DIV. 15
20AMP - 1P CIRCUIT - GFI
120V - 1‘ - .75AMP (FAN)
EF-X EXHAUST FANG
- TYPICAL AT 48" A.F.F.
CABLE CONNECTORS
FOR TELEVISION / TELEPHONE
RECESSED JUNCTION BOX W/ COVER
FAN AND LIGHT CONTROLS
FEEDER TO THIS BOX FOR FUTURE SEPARATE
ELECTRICAL CONTRACTOR TO PROVIDE 4-WIRE
TO THE LISTING INSTALLATION INSTRUCTIONS.
THEIR MANUFACTURER AND SECURED ACCORDING
(PADDLE) FAN LISTED, SHALL BE MARKED BY
ANY AREA PERIMETER WALL SHALL BE CEILING
IN DWELLING UNITS TWO FEET OR MORE FROM
CEILING MOUNTED LIGHTING J - BOXES
CA
GFI
RE-3
S
S
AFI
CW
S
S
AFI
CW
RC
S
GFI
AC
J
AFI
AFI
AFI
AFI
AFI
CA
CA CA CACACACA
S
S
3
S
3S
CAS3S3AFI
AFI
S D
L
INDEPENDENT
(MANCHESTER) COMBO UNIT (SUFOLK) COMBO UNIT
REVISIONS
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
C
o
n
t
i
n
u
i
n
g
C
a
r
e
R
e
t
i
r
e
m
e
n
t
C
a
r
m
e
l
I
n
d
i
a
n
a
071101
T
h
e
B
a
r
r
i
n
g
t
o
n
o
f
C
a
r
m
e
l
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
p
l
t
c
f
g
\
a
g
p
d
f
.
p
l
t
c
f
g
L
:
\
X
Mw
o
r
k
s
p
a
c
e
\
S
t
a
n
d
a
r
d
s
\
t
a
b
l
e
s
\
P
e
n
\
a
g
.
t
b
l
P
L
O
T
P
A
R
A
ME
T
E
R
S
:
F
I
L
E
:
K
:
\
0
7
1
1
0
1
\
C
A
D
D
G
N
\
E
I
3
0
5
.
d
g
n
6
:
1
0
:
5
6
P
M
7
/
3
1
/
2
0
1
1
P
L
O
T
T
E
D
O
N
:
4
:
0
’
:
"
/
i
n
.
L
A
S
T
S
A
V
E
:
P
E
N
T
A
B
L
E
:
7
/
3
1
/
2
0
1
1
MO
D
E
L
:
D
e
f
a
u
l
t
t
a
r
B
Y
U
S
E
R
:
A
T
S
C
A
L
E
:
U
S
I
N
G
D
R
I
V
E
R
:01 AUG 2011
FAX
TEL