HomeMy WebLinkAbout032 EI305.pdfEI305 DINING BATH GREAT ROOM BEDROOM MASTER PATIO PATIO GREAT ROOM BEDROOM MASTER W.I.C. STUDY 1/4" UNIT ELECTRICAL PLANS TJL/TAR AREA = 1615 SQFT UNITS 1.1 TRADITIONAL & 1.1 DELUXE UNITS AREA = 1515 SQFT 1.1 TRADITIONAL & 1.1 TRADITIONAL ENTRY S SHOWER 3-0 S T S S C2 S S3 DA RA RE-3 BEDROOM C2 SPSB S C2 RF RG S C2 J SPSB OUTLET ONLY SWITCH TOP 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 1.1DLX J K M J G P & SH GFI-WP AFI HVAC BD 5 S H HLF-1 CS GFI EDGE-TYPICAL TUB/SHOWER FROM HLF-1 & 3’ CLEARANCE NOTE: GFI GFI AC AFI GFI AFI AFI AFI AFI AFI AFI AFI SHOWER KITCHEN BEDROOM W.I.C. PATIO P & SH 5 SH HVAC BD HLF-1 CS GFI-WP GFI GFI GFI C E B CW 3-0 GFI AC C2 C2 AFI AFI AFI AFI AFI AFI AFI AFI AFI EDGE-TYPICAL TUB/SHOWER FROM HLF-1 & 3’ CLEARANCE NOTE: S PSB H S S T S S S D A S S PSB S 3 CA S S GFI S AFI S F S C2 RC RE-3 RF RG RD RD DA OUTLET ONLY SWITCH TOP OUTLET ONLY SWITCH TOP 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 1.1TRD AFI K M GFI J BEDROOM W.I.C. PATIO ENTRY 3-0 C2 C2 SPSB H J S S T S S S SPSB S 3 CA S3 S S S S C2 S3 RA RE-3 RF RG DA OUTLET ONLY SWITCH TOP 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 1.1TRD J K M J G P & SH 5 SH HVAC BD HLF-1CS GFI-WP GFI AFI AFI AFI AFI AFI AFI AFI AFI AFI EDGE-TYPICAL TUB/SHOWER FROM HLF-1 & 3’ CLEARANCE NOTE: AFI AFI SHOWER KITCHEN W.I.C. PATIO P & SH HVAC BD HLF-1 CS GFI-WP GFI GFI GFIGFI C E B 3-0 GFI AC C2 C2 AFI AFI AFI AFI AFI AFI AFI AFI AFI S PSB J J S T S S S D A S S S PSB S 3 CA S S S AFI S F S C2 S D RA RC RE-3 RF RG RD RD DA OUTLET ONLY SWITCH TOPOUTLET ONLY SWITCH ONE 1‘ - 3 WIRE 100 AMP - 2P - 120/208V LOADCENTER PANEL 1.1TRD AFI J K L M GFI CA EDGE-TYPICAL & TUB/SHOWER FROM HLF-1 / CA 3’ CLEARANCE NOTE: S S3 AFI AFI AFIAFI J J S AFI CA S S 3 C2 C2 H 30A - 2P COMBINATION UNIT WASHER / DRYER 20 AMP - 1P REFRIGERATOR 40 AMP - 2P RANGEB C D E A NOTES FOR THIS SHEET ONLY J K L NOTE: INSTALLATION - TYPICAL FOR ALL UNITS. AVOID CONFLICT WITH THE MEDICINE CABINET INTERIOR ELEVATION DRAWINGS SO AS TO TO BE DETERMINED PER ARCHITECTURAL OF BATHROOM SWITCHES AND OUTLETS ARE THE HORIZONTAL AND VERTICAL POSITION NOTE: TENANT TO PROVIDE FIXTURE FAN SUPPORT TO BE CENTERED IN ROOM. SWITCHED JUNCTION BOX FOR PADDLE M 20 AMP - 1P FOR WASTE DISPOSAL SWITCHED OUTLET BELOW SINK ’ADA’ UNIT NOTES - AUDIO/VISUAL FIRE ALARM DEVICE BATH FIRE ALARM DEVICE FIRE ALARM SYSTEM TO PROVIDE POWER TO VIBRATING PAD - DUPLEX RECEPTACLE NEAR BED LOCATION TIED INTO - VISUAL ALARM - SMOKE DETECTOR W/SYSTEM PROGRAMMABLE SOUNDER BASE BEDROOM - DOOR BELL W/ INDICATOR LIGHT LIVING ROOM OR HALL AREA OF BEDROOM - AUDIO/VISUAL FIRE ALARM DEVICE LIVING ROOM TO BE DESIGNATED FOR USE BY THE PHYSICALLY DISABLED IN ADDITION TO TYPICAL UNIT NOTES AT THOSE UNITS NOTE: NEC ART. 210.12 (B) ARC FAULT INTERUPTER PROTECTED PER LIVING, DINING, DEN, HALLWAYS, ETC. TO BE REMAINING RECEPTACLES IN BEDROOMS, PROTECTED PER NEC ART. 210.8 (A) TO BE GROUND FAULT INTERUPTER (GFI) RECEPTACLES IN KITCHEN AND BATHS SWITCH DISCONNECT W/ UNDERCABINET 20 AMP - 1P DISHWASHER WIRED BY ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED BY OTHERS 20 AMP - 1P 120V - 1‘ - 2.5 AMP RANGEHOOD W/ LIGHT SUPPLIED AND INSTALLED BY OTHERS IN SELF SPACE - UNIT IS PROVIDE OUTLET BEHIND UNIT 20 AMP - 1P 120V - 1‘ - 1100 WATTS MICROWAVE OVEN BY DIV. 16 PROVIDED AND INSTALLED BY DIV. 15 AND WIRED 20AMP - 1P CIRCUIT - GFI 120V - 1‘ - .75AMP (FAN) - 250 WATT (HEAT LAMP) HF-1 EXHAUST FAN/HEATER 20 AMP - 2P CIRCUIT 208V - 1‘ - MCA=14.1 AMPS MAGIC PAK HVAC UNIT HC-1 1/2 N 25 AMP - 2P CIRCUIT 208V - 1‘ - MCA=17.5 AMPS MAGIC PAK HVAC UNIT HC-2F TENANT TO PROVIDE FIXTURE SWITCHED JUNCTION BOX. P AND WIRED BY DIV. 16 PROVIDED AND INSTALLED BY DIV. 15 20AMP - 1P CIRCUIT - GFI 120V - 1‘ - .75AMP (FAN) EF-X EXHAUST FANG - TYPICAL AT 48" A.F.F. CABLE CONNECTORS FOR TELEVISION / TELEPHONE RECESSED JUNCTION BOX W/ COVER FAN AND LIGHT CONTROLS FEEDER TO THIS BOX FOR FUTURE SEPARATE ELECTRICAL CONTRACTOR TO PROVIDE 4-WIRE TO THE LISTING INSTALLATION INSTRUCTIONS. THEIR MANUFACTURER AND SECURED ACCORDING (PADDLE) FAN LISTED, SHALL BE MARKED BY ANY AREA PERIMETER WALL SHALL BE CEILING IN DWELLING UNITS TWO FEET OR MORE FROM CEILING MOUNTED LIGHTING J - BOXES CA GFI RE-3 S S AFI CW S S AFI CW RC S GFI AC J AFI AFI AFI AFI AFI CA CA CA CACACACA S S 3 S 3S CAS3S3AFI AFI S D L INDEPENDENT (MANCHESTER) COMBO UNIT (SUFOLK) COMBO UNIT REVISIONS THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. DATE PROJECT DRAWN BY C o n t i n u i n g C a r e R e t i r e m e n t C a r m e l I n d i a n a 071101 T h e B a r r i n g t o n o f C a r m e l L : \ X Mw o r k s p a c e \ S t a n d a r d s \ p l t c f g \ a g p d f . p l t c f g L : \ X Mw o r k s p a c e \ S t a n d a r d s \ t a b l e s \ P e n \ a g . t b l P L O T P A R A ME T E R S : F I L E : K : \ 0 7 1 1 0 1 \ C A D D G N \ E I 3 0 5 . d g n 6 : 1 0 : 5 6 P M 7 / 3 1 / 2 0 1 1 P L O T T E D O N : 4 : 0 ’ : " / i n . L A S T S A V E : P E N T A B L E : 7 / 3 1 / 2 0 1 1 MO D E L : D e f a u l t t a r B Y U S E R : A T S C A L E : U S I N G D R I V E R :01 AUG 2011 FAX TEL