HomeMy WebLinkAbout04110035.42ARCHITECTURAL GENERAL NOTES: ABBREVIATIONS APPLY TO ALL WORK) /� 1. GENERAL NOTES TO PERTAIN TO ALL DRAWINGS. ACT ACOUSTICAL CLG TILE FE FIRE EXTINGUISHER OC ON CENTER A ,?"m 2. THE CONTRACTOR SHALL. VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY AD AREA DRAIN FEC FIRE EXTINGUISHER CABINET PR PAIR ADA AMERICAN WITH DISABILITIES ACT FLR FLOOR PL PLATE COMMENCEMENT OF ANY WORK AFFECTED UBY�OR RELATE ATTENTION SUCH DISCREPANCY. �THEOR TO THE ADJ ADJUSTABLE FTG FOOTING PLAT PLASTIC LAMINATE CONTRACTOR sews. BE RESPONSIBLE FOR ALL Cows ASSOCIATED WITH, OR CAUSED BY FAILURE TO COMPLY WITH THIS REQUIREMENT. PLYWD PLYWOOD 3. ALL INTERIOR DIMENSIONS ARE TO FACE OF WALL OR CENTERLINE OF COLUMN, AFF ABOVE FINISHED FLOOR FT FEET PT PAINT 8" CMU WALL WITH HORIZONTAL JOINT REINFORCMENT UNLESS OTHERWISE NOTED. AL ALUMINUM GA GAUGE, GAGE 016" O.C. VERTICALLY. 4. PROVIDE ALL WOOD BLOCKING AS REQUIRED FOR THE ATTACHMENT OF QT QUARRY TILE MISCELLANEOUS EQUIPMENT INCLUDING BUT NOT LIMITED TO, TOILET ACCESSORIES, GALV GALVANIZED ANOD ANODIZED DOOR HARDWARE, ELECTRICAL DEVICES, EQUIPMENT INDICATED, R RADIUS GB GYPSUM BOARD GRAB BARS, HANDRAILS, AND CASEWORK. 16 GA. GALVANIZED SHEET METAL APPROX. APPROXIMATELY REINF. REINFORCED, REINFORCING CAN BE USED AS BLOCKING. BD BOARD GMU GLAZED MASONRY UNIT 5• TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT GST GLAZED STRUCTURAL TILE REQ'D REQUIRED CENTERLINE OF DOORS. (TYPICAL) BTWN BETWEEN RM ROOM SAMPLE WALL 6. ALL NEW DOOR FRAMES ARE TO BE 2' FROM ADJACENT FINISHED WALL SURFACE AT BLDG BUILDING GP GYPSUM PLASTER DOOR HINGE U.N.O. DIMENSION FOR OPENINGS WITH DOORS ARE TO FACE OF DOOR RO ROUGH OPENING JAMB. DIMENSION FOR OPENINGS WITHOUT DOORS ARE TO FACE OF WALL. BLK BLOCK, BLOCKING GR GRADE TYPE TAG 7. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD AS RECOMMENDED BY SC SOLID CORE WALLBOARD MANUFACTURER AND COORDINATE LOCATION WITH ARCHITECT. (APPROX. 30' O.C.) BM BENCHMARK HC HOLLOW CORE SEC SECTION A Li ALL CUTTING AND PATCHING AS A RESULT OF NEW CONSTRUCTION OR DEMOLITION BUR BUILT —UP ROOFING HDWD HARDWOOD SHAD. BE PERFORMED IN A WORKMANLIKE MANNER, AND SHALL MATCH IN COLOR, HM HOLLOW METAL SHT SHEET SHAPE, SIZE & TEXTURE ADJACENT AND /OR CONTIGUOUS FINISHED SURFACES. C PAINT ALL CUT AND PATCHED SURFACES AS SPECIFIED. AB CABINET SIM SIMILAR HORZ HORIZONTAL WALL TYPE CONSTRUCTION s. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS & COUNGS IN AREAS INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS CB CATCH BASIN SM SHEET METAL SEE WALL TYPE LEGEND ABOVE HP HIGH POINT ADJACENT TO SURFACES RECEIVING PAINT AND RELOCATE ITEMS. CJ CONTROL JOINT SP STARTING POINT 1o. REPAIR ALL SURFACES DAMAGED BY RENOVATION AND NEW CONSTRUCTION TO HT HEIGHT UL ASSEMBLIES RECEIVE FINISH SPECIFIED AS TO MATCH EXISTING ADJACENT OR CONTIGUOUS FINISH. CL CENTE2 LINE HTG HEATING SPEC SPECIFICATIONS 11. ALL PRODUCTS UTILIZED IN THIS CONSTRUCTION SHALL BE ASBESTOS FREE. CLG CEILING HVAC HEATING / VENTILATION / AIR SQ. SQUARE 1. NOTE: SEE UNDERWRITERS LABORATORIES INC. DIRECTORY. 1996 12 THE CONTRACTOR SHALL BECOME COMPLETELY FATHERS WITH ALL ASPECTS OF THE WORK, EVEN CMU CONCRETE MASONRY UNIT CONDITIONING SS STAINLESS STEEL THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THE FAMILIARIZATION INCLUDES FULL AND EDITION FOR APPROVED MANUFACTURES OF EACH COMPONENT. COMPLETE UNDERSTANDING OF THE WORK DESCRIBED ON ALL SHEETS OF THE DRAWINGS AND ALL CO CLEAN OUT ID INSIDE DIMENSION STD STANDARD SECTIONS OF THE SPECIFICATIONS. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR AND COGNIZANT OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF THE COL COLUMN IN INCH STL STEEL CONC. CONCRETE INCL INCLUDING l( STRUC STRUCTURAL WALL TYPE GENERAL NOTES . DOCUMENT. TO PROVIDE MATERIALS, ASSEMBLIES, OR SERVICE INDICATED IN THE CONTRACT 13. NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM RESPONSIBILITY TO CONT CONTINUOUS INFO INFORMATION ST &V STAIN & VARNISH 1. ALL INTERIOR STEEL SCUDS TO BE BRACED FOR MAXIMUM DEFLECTION OF L /360. PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, CID CEMENT PLASTER INSUL INSULATION SUSP SUSPENDED AT 5 Ib. s .ft. HORIZONTAL LOAD. BRACE TO STRUCTURE AS REQUIRED. ANCHORAGE, AND COORDINATION WITH OTHER TRADES, OR WANE THE CONTRACTOR'S RESPONSIBILITY / q TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, THK THICK CT CERAMIC 11LE JT JOINT 2. WHERE GYPSUM BOARD 0R PLASTER ABUTS MASONRY CONSTRUCTION, PROVIDE CONTINUOUS OR WANE THE CONTRACTOR'S RESPONSIBILITY TO ALERT THE PROJECT MANAGER/ DESIGNER TO DISCREPANCIES CONTAINED THI DEMO DEMOLITION KDHM KNOCK DOWN HOLLOW METAL TYP TYPICAL "J" —MOLD AND SEALANT AT vOINT. 14. THE CONTRACTOR SHALL REVIEW IN N AD ADVANCE ALL PORTIONS Of THE WORK TO VERIFY THAT DIA DIAMETER LAM LAMINATE UNO UNLESS NOTED OTHERWISE 3. THE INTERIOR SIDE LAYER OF GYPSUM BOARD ON ALL RESTROOM CHASE WALLS AND THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED IN THESE CONTRACT DIM DIMENSION LIN LINEAR UL UNDERWRITERS LABORATORY OTHER SHAFTS CAN BE ELIMINATED IF A FIRE RATING IS NOT COMPROMISED. DOCUMENTS. ANY QUESTIONS SHALL BE PROMPTLY REFERRED TO THE DESIGNER FOR RESOLUTION. 15. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR CLEANING AND DISPOSAL REQUIREMENTS. DF DRINKING FOUNTAIN ILL LOWER LEVEL VCT VINYL COMPOSITION TILE 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL SURFACES AND FINISHES A'; L' VENT VENTILATION INTERIOR AND EXTERIOR OF BUILDING. DAMAGED SURFACES AND FINISHES RESULTING FROM THE 8I 5� O O Li z = Ld z S o w �Q � V � ra C) T=- 2 Q CONSULTANTS DN DOW LP LOW POINT DS DOIh'�' SFr'UT MAX MAXIMUM VEST VERTICAL PERFORMANCE OF THE WORK SHALL BE REPAIRED AT NO C05f TO THE OWNER BY THE CONTRACTOR TO MATCH EXISTING ADJACENT. DWG DRAWING MC MINERAL CORE VEST VESTIBULE 17. THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR COORDINATION WITH ALL EA. EACH MECH MECHANICAL VOL VOLUME TRADES. THE CONTRACTOR SHAD. REFER TO ALL ASPECTS OF THE DRAWINGS AND SPECIFICATIONS EL ELE`lA�IOR' MEJ MASONRY EXPANSION JOINT VT VINYL TILE INCLUDING BUT NOT LIMITED TO ARCHITECTURAL DRAWINGS, STRUCTURAL DRAWINGS, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AS WELL AS RELATED SPECIFICATIONS FOR COORDINATION ELEC. ELEC' ".0 MFR MANUFACTURER W/ WITH ISSUES. COORDINATE ALL DIAGRAMMATIC DRAWINGS WITH ALL TRADES TO ENSURE FIT AND COMPATIBILITY. EP EPDXY PAINT MH MANHOLE WD WOOD EQ EQUAL MIN MINIMUM WH WALL HEATER EQUIP EQUIPMENT MISC. MISCELLANEOUS W/O WITHOUT EWC FLECTRIC' WATER COOLER MO MASONRY OPENING WWF WELDED WIRE FABRIC EXIST EXISTING MT MOUNTING EJ EXPANSION JOINT NIC NOT IN CONTRACT MATERIALS LEGENDS 1 FD FLOOR DRAIN NO NUMBER �j POURED CONCRETE GATT INSULATION 01 FEIN FOUNDATION NOM NOMINAL �. • • -� ® W SYMBOLS LEGEND 1z PRE CAST CONCRETE RIGID INSULATION SECTION /DETAIL NOTATION FLOOR ELEVATION SYMBOL y�•,� BLOCK LIEX 12' -0" N �--- SHEET WHERE SECTION IS DRAWN _ 04 TOP OF BEAM BRICK GRAVEL/FILL - No. — N �- _ AR19500167 SECTION REFERENCE ON SHEET �/�,�%%j�.�%'�- STATE OF DOOR SYMBOL WINDOW SYMBOL 11 =1LI _ EARTH CUT STONE 112 —A �1 — — — ' gRCH l T � �``• ELEVATION SYMBOLS : -_ GYPSUM BOARD PIASTER Drown oww 0 -- SHEET WHERE ELEVATION IS DRAWN ROOM NAMEMUMBER SYMBOL ROUGH WOOD PARTICAL BOARD Checked •— NAR Approved N CLASSROOM_.., ROOM NAME ~---- DETAIL REFERENCE ON SHEET A101 PLYWOOD oo Score oo ROOM NUMBER AS NOTED STRUCTURAL STEEL Sheet ® FINISHED WOOD 00 AOO Date 06/13/01 Project number PIC 0000325 -70000