HomeMy WebLinkAbout04110035.42ARCHITECTURAL GENERAL NOTES:
ABBREVIATIONS APPLY TO ALL WORK)
/�
1. GENERAL NOTES TO PERTAIN TO ALL DRAWINGS.
ACT ACOUSTICAL CLG TILE FE FIRE EXTINGUISHER OC ON CENTER A ,?"m 2. THE CONTRACTOR SHALL. VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS
SHOWN ON THE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY
AD AREA DRAIN FEC FIRE EXTINGUISHER CABINET PR PAIR
ADA AMERICAN WITH DISABILITIES ACT FLR FLOOR
PL PLATE COMMENCEMENT OF ANY WORK AFFECTED UBY�OR RELATE ATTENTION SUCH DISCREPANCY. �THEOR TO THE
ADJ ADJUSTABLE FTG FOOTING PLAT PLASTIC LAMINATE CONTRACTOR sews. BE RESPONSIBLE FOR ALL Cows ASSOCIATED WITH, OR CAUSED BY FAILURE
TO COMPLY WITH THIS REQUIREMENT.
PLYWD PLYWOOD 3. ALL INTERIOR DIMENSIONS ARE TO FACE OF WALL OR CENTERLINE OF COLUMN,
AFF ABOVE FINISHED FLOOR FT FEET
PT PAINT 8" CMU WALL WITH HORIZONTAL JOINT REINFORCMENT UNLESS OTHERWISE NOTED.
AL ALUMINUM GA GAUGE, GAGE 016" O.C. VERTICALLY. 4. PROVIDE ALL WOOD BLOCKING AS REQUIRED FOR THE ATTACHMENT OF
QT QUARRY TILE MISCELLANEOUS EQUIPMENT INCLUDING BUT NOT LIMITED TO, TOILET ACCESSORIES,
GALV GALVANIZED
ANOD ANODIZED DOOR HARDWARE, ELECTRICAL DEVICES, EQUIPMENT INDICATED,
R RADIUS
GB GYPSUM BOARD GRAB BARS, HANDRAILS, AND CASEWORK. 16 GA. GALVANIZED SHEET METAL
APPROX. APPROXIMATELY REINF. REINFORCED, REINFORCING CAN BE USED AS BLOCKING.
BD BOARD GMU GLAZED MASONRY UNIT 5• TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT
GST GLAZED STRUCTURAL TILE REQ'D REQUIRED CENTERLINE OF DOORS. (TYPICAL)
BTWN BETWEEN RM ROOM SAMPLE WALL 6. ALL NEW DOOR FRAMES ARE TO BE 2' FROM ADJACENT FINISHED WALL SURFACE AT
BLDG BUILDING GP GYPSUM PLASTER DOOR HINGE U.N.O. DIMENSION FOR OPENINGS WITH DOORS ARE TO FACE OF DOOR
RO ROUGH OPENING JAMB. DIMENSION FOR OPENINGS WITHOUT DOORS ARE TO FACE OF WALL.
BLK BLOCK, BLOCKING GR GRADE TYPE TAG 7. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD AS RECOMMENDED BY
SC SOLID CORE WALLBOARD MANUFACTURER AND COORDINATE LOCATION WITH ARCHITECT. (APPROX. 30' O.C.)
BM BENCHMARK HC HOLLOW CORE SEC SECTION
A Li ALL CUTTING AND PATCHING AS A RESULT OF NEW CONSTRUCTION OR DEMOLITION
BUR BUILT —UP ROOFING HDWD HARDWOOD SHAD. BE PERFORMED IN A WORKMANLIKE MANNER, AND SHALL MATCH IN COLOR,
HM HOLLOW METAL SHT SHEET SHAPE, SIZE & TEXTURE ADJACENT AND /OR CONTIGUOUS FINISHED SURFACES.
C PAINT ALL CUT AND PATCHED SURFACES AS SPECIFIED.
AB CABINET SIM SIMILAR
HORZ HORIZONTAL WALL TYPE CONSTRUCTION s. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS & COUNGS IN AREAS
INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS
CB CATCH BASIN SM SHEET METAL SEE WALL TYPE LEGEND ABOVE
HP HIGH POINT ADJACENT TO SURFACES RECEIVING PAINT AND RELOCATE ITEMS.
CJ CONTROL JOINT SP STARTING POINT 1o. REPAIR ALL SURFACES DAMAGED BY RENOVATION AND NEW CONSTRUCTION TO
HT HEIGHT UL ASSEMBLIES RECEIVE FINISH SPECIFIED AS TO MATCH EXISTING ADJACENT OR CONTIGUOUS FINISH.
CL CENTE2 LINE HTG HEATING SPEC SPECIFICATIONS 11. ALL PRODUCTS UTILIZED IN THIS CONSTRUCTION SHALL BE ASBESTOS FREE.
CLG CEILING HVAC HEATING / VENTILATION / AIR SQ. SQUARE 1. NOTE: SEE UNDERWRITERS LABORATORIES INC. DIRECTORY. 1996 12 THE CONTRACTOR SHALL BECOME COMPLETELY FATHERS WITH ALL ASPECTS OF THE WORK, EVEN
CMU CONCRETE MASONRY UNIT CONDITIONING SS STAINLESS STEEL THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THE FAMILIARIZATION INCLUDES FULL AND
EDITION FOR APPROVED MANUFACTURES OF EACH COMPONENT. COMPLETE UNDERSTANDING OF THE WORK DESCRIBED ON ALL SHEETS OF THE DRAWINGS AND ALL
CO CLEAN OUT ID INSIDE DIMENSION STD STANDARD SECTIONS OF THE SPECIFICATIONS. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR
AND COGNIZANT OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF THE
COL COLUMN IN INCH STL STEEL
CONC. CONCRETE INCL INCLUDING l(
STRUC STRUCTURAL WALL TYPE GENERAL NOTES . DOCUMENT.
TO PROVIDE MATERIALS, ASSEMBLIES, OR SERVICE INDICATED IN THE CONTRACT
13. NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM RESPONSIBILITY TO
CONT CONTINUOUS INFO INFORMATION ST &V STAIN & VARNISH 1. ALL INTERIOR STEEL SCUDS TO BE BRACED FOR MAXIMUM DEFLECTION OF L /360. PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION,
CID CEMENT PLASTER INSUL INSULATION SUSP SUSPENDED AT 5 Ib. s .ft. HORIZONTAL LOAD. BRACE TO STRUCTURE AS REQUIRED. ANCHORAGE, AND COORDINATION WITH OTHER TRADES, OR WANE THE CONTRACTOR'S RESPONSIBILITY
/ q TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS,
THK THICK
CT CERAMIC 11LE JT JOINT 2. WHERE GYPSUM BOARD 0R PLASTER ABUTS MASONRY CONSTRUCTION, PROVIDE CONTINUOUS OR WANE THE CONTRACTOR'S RESPONSIBILITY TO ALERT THE PROJECT MANAGER/ DESIGNER
TO DISCREPANCIES CONTAINED THI
DEMO DEMOLITION KDHM KNOCK DOWN HOLLOW METAL TYP TYPICAL "J" —MOLD AND SEALANT AT vOINT.
14. THE CONTRACTOR SHALL REVIEW IN N AD ADVANCE ALL PORTIONS Of THE WORK TO VERIFY THAT
DIA DIAMETER LAM LAMINATE UNO UNLESS NOTED OTHERWISE 3. THE INTERIOR SIDE LAYER OF GYPSUM BOARD ON ALL RESTROOM CHASE WALLS AND THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED IN THESE CONTRACT
DIM DIMENSION LIN LINEAR UL UNDERWRITERS LABORATORY OTHER SHAFTS CAN BE ELIMINATED IF A FIRE RATING IS NOT COMPROMISED. DOCUMENTS. ANY QUESTIONS SHALL BE PROMPTLY REFERRED TO THE DESIGNER FOR RESOLUTION.
15. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR CLEANING AND DISPOSAL REQUIREMENTS.
DF DRINKING FOUNTAIN ILL LOWER LEVEL VCT VINYL COMPOSITION TILE 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL SURFACES AND FINISHES A';
L' VENT VENTILATION INTERIOR AND EXTERIOR OF BUILDING. DAMAGED SURFACES AND FINISHES RESULTING FROM THE
8I
5�
O
O
Li
z
=
Ld
z
S o
w
�Q
�
V
�
ra
C)
T=-
2
Q
CONSULTANTS
DN DOW LP LOW POINT
DS DOIh'�' SFr'UT MAX MAXIMUM VEST VERTICAL PERFORMANCE OF THE WORK SHALL BE REPAIRED AT NO C05f TO THE OWNER BY THE CONTRACTOR
TO MATCH EXISTING ADJACENT.
DWG DRAWING MC MINERAL CORE VEST VESTIBULE 17. THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR COORDINATION WITH ALL
EA. EACH MECH MECHANICAL VOL VOLUME TRADES. THE CONTRACTOR SHAD. REFER TO ALL ASPECTS OF THE DRAWINGS AND SPECIFICATIONS
EL ELE`lA�IOR' MEJ MASONRY EXPANSION JOINT VT VINYL TILE INCLUDING BUT NOT LIMITED TO ARCHITECTURAL DRAWINGS, STRUCTURAL DRAWINGS, MECHANICAL,
ELECTRICAL AND PLUMBING DRAWINGS AS WELL AS RELATED SPECIFICATIONS FOR COORDINATION
ELEC. ELEC' ".0 MFR MANUFACTURER W/ WITH ISSUES. COORDINATE ALL DIAGRAMMATIC DRAWINGS WITH ALL TRADES TO ENSURE FIT AND
COMPATIBILITY.
EP EPDXY PAINT MH MANHOLE WD WOOD
EQ EQUAL MIN MINIMUM WH WALL HEATER
EQUIP EQUIPMENT MISC. MISCELLANEOUS W/O WITHOUT
EWC FLECTRIC' WATER COOLER MO MASONRY OPENING WWF WELDED WIRE FABRIC
EXIST EXISTING MT MOUNTING
EJ EXPANSION JOINT
NIC NOT IN CONTRACT MATERIALS LEGENDS 1
FD FLOOR DRAIN NO NUMBER
�j POURED CONCRETE GATT INSULATION 01
FEIN FOUNDATION NOM NOMINAL �. • • -� ® W
SYMBOLS LEGEND 1z
PRE CAST CONCRETE RIGID INSULATION
SECTION /DETAIL NOTATION FLOOR ELEVATION SYMBOL y�•,�
BLOCK LIEX
12' -0"
N �--- SHEET WHERE SECTION IS DRAWN _
04 TOP OF BEAM BRICK GRAVEL/FILL
- No. —
N �- _ AR19500167
SECTION REFERENCE ON SHEET
�/�,�%%j�.�%'�- STATE OF
DOOR SYMBOL WINDOW SYMBOL 11 =1LI _ EARTH CUT STONE
112 —A �1 — — — ' gRCH l T � �``•
ELEVATION SYMBOLS : -_ GYPSUM BOARD PIASTER Drown
oww
0 -- SHEET WHERE ELEVATION IS DRAWN ROOM NAMEMUMBER SYMBOL ROUGH WOOD PARTICAL BOARD Checked •— NAR
Approved
N CLASSROOM_.., ROOM NAME
~---- DETAIL REFERENCE ON SHEET
A101 PLYWOOD oo Score
oo ROOM NUMBER AS NOTED
STRUCTURAL STEEL Sheet
® FINISHED WOOD 00 AOO
Date
06/13/01
Project number
PIC 0000325 -70000