HomeMy WebLinkAbout04110005.34L
E
E
7
v
1-
G
a
00
N
O
N
M
N
7
O
J
Ql
3
.o
c
ro
CL
a�
0
O
O
N
00
1
cii
W
Z
J
N
N
X
Q
° LINE
w
0' -6"
io m MIN.
�B
S
a
w
0
0
l' -0 "(MIN.)
(CONFORM TO LOCAL REQUIREMENTS)
2' -0" DIA.X2' -0 "DEEP
DRAINAGE PIT
V
IN ACCORDANCE
WITH SPECIFICATIONS
GATE
VALVE WATER MAIN TEE OR
CONCRETE-,/ CONCRETE
CONCRETE BEARING PAD THRUST BLOCK
THRUST BLOCK OR ANCHOR
CAST -IN -PLACE AGAINST BLOCKING IF
UNDISTURBED GROUND REQUIRED
FIRE HYDRANT DETAIL
(NO SCALE)
ALL WATERMAIN SERVICE LINES TO
TERMINATE 8 FEET BEHIND SIDEWALK
AND MARKED WITH A 4" PVC PIPE
WITH A PAINTED BLUE TOP.
NOTE: POST -CAPS OR EQUIVALENT IS
REQUIRED ON ALL WATER
VALVE INSALLATION AND MEGA LUGS
MUST BE INSTALLED AT ALL
MECHANICAL JOINTS.
NO WATERMAIN VALVES ARE TO BE
PLACED WITHIN THE STREETS, CURBS,
OR SIDEWALKS.
INSTALL WATERMAIN TRACER WIRE
WITH ALL WATER MAINS LAID.
AND WARNING TAPE MUST BE INSTALLED
12" TO 18" ABOVE ALL WATERMAINS LAID
FULL DEPTH GRANULAR BACKFILL IS
NEEDED FOR ALL STREET CROSSINGS
ALL WATERMAINS SHALL BE
DUCTILE IRON AND INSTALLED PER
THE CITY OF CARMEL SPECIFICATIONS
CONTACT CARMEL UTILITIES FOR
WATER MAIN LOCATIONS.
O.D. + 1'
1 " CORP.
COCK
ujiJ
w
CL
0
CL
1 " COPPER SERVICE
15' -20'
ANGLE VALVE
PROTECTED °.
WITH PLASTIC
WRAP
PIPE TO BE SUPPORTED ALONG ENTIRE
LENGTH - EXCAVATE FOR EACH JOINT
WATER SERVICE INSTALLATION
(NO SCALE)
NOTE:
FIRE HYDRANT MARKERS TO BE INSTALLED
IN THE STREET PAVEMENT PERPENDICULAR
TO THE FIRE HYDRANT.
SCALE: 1 "= 50'
�.�`� p, R INC,
,%%
10200495
-o'•. STATE OF
S�ONAL E `��.��.
/ "Win 11'1110
PRESSURE PIPE JOINT RESTRAINT TABLE
LENGTH OF IPE TO BE RESTRAINED
Y
Q
IN
EACH
DIRECTION
FROM
1/4 OF 13END
BASED ON
150 psi TEST PRESSURE
DEGREE OF
6"
8"
10" 12"
14"
16" 18" 20"
24"
30"
BEND
N
90 °1 TEES
27'
35'
42
50'
58'
65'
73'
80
95'
115'
& PLUGS
¢
45°
7'
9'
11'
13'
15'
17'
19'
21'
24'
29'
22-1/2'
3'
4'
5'
6'
7'
8'
9'
10'
12'
14'
11 -1 /4°
2'
2'
3'
3'
4'
4'
4
5'
6'
7'
RESTRAINED JOINTS SHALL BE MECHANICAL JOINT MEGALUG WITH RETAINER GLANDS,
US PIPE TR FLEX JOINT SYSTEM, US PIPE FIELD LOK GASKET SYSTEM,
OR EQUAL.
NOTE: THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS
THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED.
LEGEND
r
Y m
(A 0
F- z
w O
V)
0 5; o w
r �
U
z
w
c�
a
W
a
0
W
s
w
0
0
w
o'
w
U
V) N
af �
O Ln
>- I
w m
> d-
D
V)
0 X
Z Q
J
V
w
Z_
0
C� 00
Z
W
Ln
0
Z �
L'
00
O
U
Q
z
Q
0
z
w
PROPOSED HYDRANT W /6" VALVE 0
Q
O
VAL VE Of
BLOW OFF ASSEMBL Y W
Z :711.J
b REDUCER Q 3:z 00
z
NOTE:
ALL HYDRANTS SHALL INCLUDE A 6" VALVE. cy— O
Q
�I
J
W
C701
JOB N0.48700S1
Q
z
Q
0
z
J
LLJ
Q
U
Y
Q
o
W
F-
�
Q
N
r
m U
m N
LL
L O
��
¢
0
0
w
o'
w
U
V) N
af �
O Ln
>- I
w m
> d-
D
V)
0 X
Z Q
J
V
w
Z_
0
C� 00
Z
W
Ln
0
Z �
L'
00
O
U
Q
z
Q
0
z
w
PROPOSED HYDRANT W /6" VALVE 0
Q
O
VAL VE Of
BLOW OFF ASSEMBL Y W
Z :711.J
b REDUCER Q 3:z 00
z
NOTE:
ALL HYDRANTS SHALL INCLUDE A 6" VALVE. cy— O
Q
�I
J
W
C701
JOB N0.48700S1
Q
z
Q
0
z
J
LLJ
Q
U