EDGE OF PAVEMENT, CURB, MIN. 6” TOPSOIL TO
GUTTER OR SIMILAR STRUCTURE ENSURE GRASS GROWTH
IN THE PUBLIC RIGHT -OF -WAY
T�
STANDARD HEX. HEAD
BRASS PLUG. TOP OF 5' _ 0" MAX. FINISH FLOOR
CASTING ELEV. AS
SHOWN IN PLANS. WITHIN 5' OF EDGE OF PAVEMENT
"B" BORROW OR EQUN, GRANULAR REGULAR NOTE.
MATERIAL COMPACTED TO 90% STANDARD BACKFILL WITHIN 5' OF EDGE OF PAVEMENT
GROUND LINE� PROCTOR DENSITY, ALL OTHER A = 1.25Bc + 12"
CONDITIONS REGULAR BACKFILL ALLOWABLE. OUTSIDE 5' OF EDGE OF PAVEMENT
9"
A 1.25Bc I I
_'
11-1TI ='' " DIA.
III_ B" BORROW OR EQUIV. i
III =� GRANULAR MATERIAL
12" X 12" X 4" COMPACTED TO 90% i �! 1/2 Be Bc Y 3 Z
CONC. COLLAR a STANDARD PROCTOR '� Bc ;_„ �, 4" 12" C TO C O
DENSITY � MAX. SPACING �
45' ELBOWS \��.i.. �\ii`i`�i��ii o `� W LL 1 1/2"R NEENAH ANCHOR BOLTS CASTING (SEE PLANS)
6 PIPE 1 Y
' SANITARY BUILDING DRAIN DEPTH OF BEDDING
„
MATERIAL BELOW PIPE
LEGEND � GROUT AND BOLT TO
D (d) MIN. NOTE: Bc = OUTSIDE DIAMETER
PLAN VIEW SECTION Y -Y PROVIDE WATERTIGHT SEAL CONCRFE.AMDJU ER RING
ALL BEDDING AND INITIAL BACKFILL (1
WYE INVERT ELEV. AS 27" & SMALLER 3" SHALL BE INSTALLED IN 6" D = INSIDE DIAMETER
SHOWN IN PLANS TO 12" BALANCED LIFTS GROOVED END ON OUTLET END 3,•� ° a
30" TO 60" 4" d MATERIAL OFB BEDDING
PIPE TONGUE END ON INLET END 4; FCC S FAG( S�OpF CONCRETE END W
"� A MINIMUM 9" CLEARANCE
CLEAN OUT 66" & LARGER 6" SHALL BE PROVIDED ON EACH D �OpF _ SECTION CL
SIDE OF THE INSTALLED PIPE a C B= D -C CULVERT I CONCRETE ADJUSTER RING �,
NO SCALE REINFORCED CONCRETE PIPE (RCP) 3
0
COMPUTED LENGTH OF CULVERT., I NO SCALE
TRENCH DETAIL
o A a PAY LENGTH OF CULVERT
9
NO SCALE z_END SECTION d
J O
LENGTH (D) Z
3 N SLOPE DETAIL
A o
GROOVE (OR TONGUE) TO 12 "C. TO C.
BE THE SAME AS ON MAX. SPACING 3/4 "x12" HOOK � 0
BOLTS GALV. Z
STANDARD REINFORCED M
CONCRETE PIPE ASTM HOOK
I n. o N Ln
DESIGNATION C 76 a
W
LONGITUDINAL SECTION o
t a . "a w
° N e e _ e a N iii lx Lu
e 5' OR LESS MIN. 6" TOPSOIL TO ` GLASS' ,CONGRE�E
IF NOTE UNDER PAVEMENT _ E + 2T _
I
5" N 24,. 5" OUTLET PIPE < .
_ _ SECTION A —A
Ili
IIII II MIN. 1.25 Be + 12" III
Lo
° EDGE OF PAVEMENT CURB �I r
DIA.
WALL
WT. SEC.
GUTTER OR SIMILAR STRUCTURE
-
C
D
SEE PLANS FOR
IN THE
PUBLIC RIGHT -OF -WAY
SKIRT
12
2
CASTING TYPE
4
24
48 7/8
72 7/8
24
5„ 5„
9
3 1/2
12" (MIN.)
2 1/4
740
24'
27
"B" BORROW OR EQUIV.
#8 CRUSHED STONE OR
30
12 1/2
11
3 1/2
GRANULAR MATERIAL
APPROVED EQUIV. CLASS I
990
9
a
46
COMPACTED TO 95%
_ BEDDING MATERIAL HAND
15 1/2
12
4
21
STANDARD PROCTOR
TAMPED AND WALKED INTO
9
35
38
73
DENSITY
111 PLACE
13
w
24
3
1520
9 1/2
43 1/2
30
d
48
16 11/16
14
4 1/2
>
3 1/4
1930
10 1/2
Tf�ll III- 4"
25 1/2
73 1/2
d °a a
I
17 3/4
14 1/2
i'r TV,'
30
3 1/2
e O
12
LEGEND
M ='
73 3/4
60
d
Be
= OUTSIDE DIAMETER
NOTE:
3 3/4
3150
,< °
58 1/2
39 1/4
ALL BEDDING AND INITIAL PACKFILL
66
23 3/4
17 1/2
D
= INSIDE DIAMETER
6
4100
15
63
d
= DEPTH OF BEDDING
T0�12 "BEBAIANCEDELFTS
24 1/16
20
5 1/2
42
MATERIAL BELOW PIPE
A MINIMUM 9" CLEARANCE
21
63
6" #8 STONE BEDDING
98
78
SHALL BE PROVIDED ON EACH
22
5 1/2
48
5
6550
SIDE OF THE INSTALLED PIPE
72
26
NOTE: 5" CONC. PRECAST OR
84
28 1/8
22
5 3/4
54
POURED IN PLACE
8040
27
65
DIA.
WALL
WT. SEC.
A
B
C
D
E
R -1
R -2
SKIRT
12
2
530
4
24
48 7/8
72 7/8
24
10 1/16
9
3 1/2
15
2 1/4
740
6
27
46
73
30
12 1/2
11
3 1/2
18
2 1/2
990
9
27
46
73 1
36
15 1/2
12
4
21
2 3/4
1280
9
35
38
73
42
16 1/8
13
4
24
3
1520
9 1/2
43 1/2
30
73 1/2
48
16 11/16
14
4 1/2
27
3 1/4
1930
10 1/2
48
25 1/2
73 1/2
54
17 3/4
14 1/2
4 1/2
30
3 1/2
2190
12
54
19 3/4
73 3/4
60
18 5/16
15
5
33
3 3/4
3150
13 1/2
58 1/2
39 1/4
97 3/4
66
23 3/4
17 1/2
5 1/2
36
4
4100
15
63
34 3/4
97 3/4
72
24 1/16
20
5 1/2
42
4 1/2
5380
21
63
35
98
78
27 1/4
22
5 1/2
48
5
6550
24
72
26
98
84
28 1/8
22
5 3/4
54
5 1/2
8040
27
65
35
100
90
32 7/8
24
6 1/4
60
6
8750
30
60
39
99
96
36 3/4
24
6 3/4
66
16 1/2
10630
24
78
21
99
102
35 11/16
24
7 1/4
72
7
12520
34
78
21
99
108
38 5/8
24
7 3/4
78
7 1/2
1 14430
24
78
21
99
114
41 15T1_6
24
8 1/2
84
8
16350
24
78
21
99
120
44 13/16
24
9
N
o v 00
Lo
v C
J E viO)OCn
00 �%K A A UJ v a 0 n
O c to N �'`
.
v
- - -- - p�vcNO�Q
I� � f) Li
i H
i
PLASTIC PIPE (PVC & HDPE) *TOLERANCE 1f
n INLET TYPE A TRENCH DETAIL
N NOTES:
(TYPICAL) (WITHIN 5' FROM EDGE OF PAVEMENT)
CONCRETE IN THESE SECTIONS SHALL BE THE SAME GRADE AND STRENGTH AS SPECIFIED FOR REINFORCED PLACE X�" DIAMETER EXTRUDABLE
NO SCALE CONCRETE PIPE, A.S.T.M. DESIGNATION C -76 CLASS II (AS SET OUT IN STANDARD SPECIFICATIONS).
,n (12" TO 18" PIPES) PREFORMED GASKET MATERIAL IN EACH
0 'r NO SCALE REINFORCEMENT IN THE "C" PORTION SHALL BE THE SAME AS SPECIFIED FOR THE REINFORCED CONCRETE, ( )'
KEYWAY SEE DETAIL NON ASPHALTIC
N A.S.T.M. DESIGNATION C -76 CLASS 11 FOR THE SIZE OF CONNECTING PIPE. MASTIC OR BUTYL RUBBER PLASTER
ACCEPTED ALTERNATIVE,
o REINFORCEMENT IN THE "B" PORTION SHALL HAVE A CROSS SECTIONAL AREA EQUAL TO THAT OF ONE LAYER
OF STEEL IN THE "C" PORTION, PLAN VIEW 63'
-°, THE END OF THE PIPE CULVERT SHALL BE PLACED IN THE CONCRETE END SECTION SO THAT THE FLOW LINES
ARE FLUSH. THE JOINT SHALL BE COMPLETELY FILLED WITH MORTAR. PRECAST CONCRETE
IN 3:1 OR 4:1 FILL SLOPE, CHANGE TO THE SLOPE OF THE END SECTION IN A SMOOTH, PLEASING TRANSITION ADJUSTING RING OR
0 APPROXIMATELY 10' -0 IN LENGTH. FLANGE OF CASTING a N
10' MIN, VARIATIONS IN DIMENSIONS - THE THICKNESS OF THE CONCRETE, THE POSITION OF STEEL, AND THE INTERNAL a a a ° 4 1
DIAMETER OF THE PIPE SHALL CONFORM WITH THE VARIATIONS IN DIMENSIONS AS PROVIDED IN THE N
SPECIFICATIONS FOR REINFORCED CONCRETE CULVERT, STORM DRAIN, AND SEWER PIPE, A.S.T.M. DESIGNATION
E WATER MAIN GREATER THAN 5' C -76.
y� E IN. 6" TOPSOIL TO a
- WATER MAIN ENSURE GRASS GROWTH W
� CONCRETE PIPE TOE ANCHORS SHALL BE REQUIRED ON ALL CONCRETE PIPE END SECTIONS. NOMINAL Yj BUTYL RUBBER I t'1
SANITARY OR STORM SEWER - "t=1�-
BASE EXTRUDABLE PREFORMED
m - - - - GASKET MATERIAL (TYP.) OR 24 "LD. C-4 //�
11=11 I II I - VICE.- ACCEPTED ALTERNATIVE. 34 "O.D, Z W �/�
=TICI
II�I MIN. 1.25 Be + 12 ' III Z
EDGE OF PAVEMENT, CURB,_II Ilm REGULAR PRECAST CONCRETE END SECTION GASKET DETAIL SECTION A —A W 3: 1 —
_T WATER MAIN WATER MAIN GUTTER OR SIMILAR STRUCTURE II BACKFILL
RATED PIPE WATER
IN THE PUBLIC RIGHT -OF -WAY NO SCALE Z
NOTE: WHEN LATERAL SEPARATION W
S 10' OR GREATER NO VERTICAL SANITARY OR
CLEARANCE IS NEEDED. STORM SEWER 12" (MIN.) PRECAST CONCRETE W W
_ I' ADJUSTING RING DETAIL p� —J 0
N 0 PROVED EQUIV. CLASS I NO SCALE CRUSHED STONE OR LU u
BEDDING MATERIAL HAND Ili
P TAMPED AND WALKED INTO LAC rl II
CD 1
mli
0 (MIN.) 10 (MIN.)
OR WATER MAIN SANITARY OR II Bc 4„
v SANITARY LESS THAN 18 OR IN C ASES STORM SEWER =
' STORM SEWER WHERE WATER IS BELOW II�II��_
-0 2 SANITARY SEWER � �� cl I �I I I I I I I I I
-- TI�Il_II rI�, un
0 MIN, (TYV 0 LEGEND
Be = OUTSIDE DIAMETER NOTE:
a) D = INSIDE DIAMETER ALL BEDDING AND INITIAL pACKFILL
•cm WATER MAIN RATED PIPE FLEXIBLE COUPLING OR ADAPTER SHALL BE INSTALLED IN 6
°' FLEXIBLE COUPLING OR ADAPTER d =DEPTH OF BEDDING TO 12" BALANCED LIFTS
CONCRETE COLLAR MATERIAL BELOW PIPE
A MINIMUM 9" CLEARANCE
c CONCRETE COLLAR SHALL BE PROVIDED ON EACH
W SIDE OF THE INSTALLED PIPE
W
MINIMUM CROSSOVER & SEPARATION PLASTIC PIPE (PVC & HDPE
REQUIREMENTS FOR WATER MAINS, TRENCH DETAIL
N SHEET NO.
(GREATER THAN 5' FROM EDGE OF PAVEMENT)
"' SANITARY SEWERS & STORM SEWERS
� NO SCALE
NO SCALE
C601