Loading...
HomeMy WebLinkAbout04110041.13POWER PLAN - SECOND FLOOR � OTGIE ,, s �. RTU I I RTU SYMBOLS LEGEND � E EMERGENCY LIGHT WITH LIGHTED EXIT SIGN MOUNTED 18' BELOW FINISHED CEILING LEVEL, UNLESS OTHERWISE NOTED. EMERGENCY LIGHT WITH BATTERY BACK -UP. VERIFY FINAL LOCATION WITH OWNER (TYPICAL) EXIT LIGHT ®SUPPLY AIR DIFUSER. REFER TO MECHANICAL DRAWINGS FOR SIZE AND LOCATION. (TYPICAL) IRETURN AIR GRILL. REFER TO MECHANICAL DRAWINGS FOR SIZE AND LOCATION. (TYPICAL) a I CEILING MOUNTED EXHAUST FAN. I SINGLE POLE SWITCH 2OA -120V a 4' -0' AFF. (D I THERMOSTAT 0 60' AFF. Q TELEPHONE JACK s 14' AFF, UNLESS NOTED OTHERWISE. J -BOX 4 RACEWAY ABOVE CEILING IDATA DROP 5 14' AFF. UNLESS NOTED OTHERWISE. J -BOX 4 RACEWAY ABOVE CEILING. o I EXISTING ELECTRICAL PANEL E)-- i SINGLE OUTLET AND T.V. CABLE JACK s 2' BELOW CEILING. =0 I DUPLEX OUTLET 2VA -120V s 14' AFF. UNLESS NOTED OTHERWISE. =Owl I DUPLEX OUTLET W/ GROUND FAULT INTERRUPTER I COUNTER HEIGHT DUPLEX OUTLET 4)I13 I DUPLEX OUTLET W/ ISOLATED GROUND :0220V 1220V DUPLEX CC44VENIENCE OUTLET o 14' AFF. UNLESS NOTED OTHERWISE I ® DUPLEX OUTLET W/ WEATHERPROOF COVER AND GROUND FAULT INTERRUPTER s 14' AFF. 0 I QUADRAPLEX OUTLET - 14' AFF. UNLESS NOTED OTHERWISE Q) I JUNCTION BOX Q TIME CLOCK NOTES THIS DRAWING REPRESENTS THE GENERAL SCOPE OF THE PROJECT BUT DOES NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FJLL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. THE TRADE CONTRACTORS SHALL PERFORM SUCH SERVICES ABD FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION OF THE PROJECT. ANY DEVICES NOT SHODUN (I.E. FANS OR SPEAKERS) SHALL BE CENTERED IN CEILING TILES AND BETWEEN LIGHTS IN EACH DIRECTION. FOR SYMBOLS SHOWN IN THE LEGEND BUT DO NOT SHOW ON THE DRAWING MAY BE RELATED TO OTHER DISIPLINES AND MAY SHOW UP ON OTHER DRAWINGS. REFER TO THE MECHANICAL AND ELECTRICAL DRAWINGS. F— 7771 FMAITINGLY CORPORATION 10150 LANTERN ROAD, SUITE 100 FISHERS, INDIANA 46038 317 - 577 -9688 CONSTRUCTION DRAWINGS OCTOBER 11, 2002 REVISION& 1Q RRETSEI1N 2LREVISION DATE AREVISION A4 REVISION N A REVISION DA E N PLOT DATE: NA DRAWN BY- CHECKED BY D PETERSON PROJECT NUMBER 02 -0086 ELECTRICAL POWER PLAN E101 THESE DRAWINGS ARE GIVEN IN CONFIDENCE AND SHALL 5E USED ONLY IN PURSUANT TO THE AGREEMENT WITH PETERSON ARCHITECTURE, P.C. NO OTHER USE OR DUPLICATION MAY BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF PETERSON ARCHITECTURE, P.C. ALL OTHER COPYRIGHT AND COMMON LAW RIGHTS ARE HEREBY SPECIFICALLY RESERVED. 01 �2 3 -'4 CONDUITS W/ 1' CONDUIT 2 -112' CONDUIT 4 -500 MCM EA W/ 3 -% W/ 4 -3/0 2 -1/2' CONDUIT W/ 4 -3/0 A B UTILITY MDP 200 AMP 200 AMP EXISTING TRANSFORMER 12 3P4W 3P4W 8P CABINET O 3P� 120/208V 120/208V ,4,W 120/208V 120/208V UTILITY METERING T, 2 -04 CONDUITS W/ 4- 500MCM EA. T GROUNDING 3 -414 CONDUIT PER NEC BY UTILITY 2002 ELECTRICAL RISER DIAGRAM NO SCALE SYMBOLS LEGEND � E EMERGENCY LIGHT WITH LIGHTED EXIT SIGN MOUNTED 18' BELOW FINISHED CEILING LEVEL, UNLESS OTHERWISE NOTED. EMERGENCY LIGHT WITH BATTERY BACK -UP. VERIFY FINAL LOCATION WITH OWNER (TYPICAL) EXIT LIGHT ®SUPPLY AIR DIFUSER. REFER TO MECHANICAL DRAWINGS FOR SIZE AND LOCATION. (TYPICAL) IRETURN AIR GRILL. REFER TO MECHANICAL DRAWINGS FOR SIZE AND LOCATION. (TYPICAL) a I CEILING MOUNTED EXHAUST FAN. I SINGLE POLE SWITCH 2OA -120V a 4' -0' AFF. (D I THERMOSTAT 0 60' AFF. Q TELEPHONE JACK s 14' AFF, UNLESS NOTED OTHERWISE. J -BOX 4 RACEWAY ABOVE CEILING IDATA DROP 5 14' AFF. UNLESS NOTED OTHERWISE. J -BOX 4 RACEWAY ABOVE CEILING. o I EXISTING ELECTRICAL PANEL E)-- i SINGLE OUTLET AND T.V. CABLE JACK s 2' BELOW CEILING. =0 I DUPLEX OUTLET 2VA -120V s 14' AFF. UNLESS NOTED OTHERWISE. =Owl I DUPLEX OUTLET W/ GROUND FAULT INTERRUPTER I COUNTER HEIGHT DUPLEX OUTLET 4)I13 I DUPLEX OUTLET W/ ISOLATED GROUND :0220V 1220V DUPLEX CC44VENIENCE OUTLET o 14' AFF. UNLESS NOTED OTHERWISE I ® DUPLEX OUTLET W/ WEATHERPROOF COVER AND GROUND FAULT INTERRUPTER s 14' AFF. 0 I QUADRAPLEX OUTLET - 14' AFF. UNLESS NOTED OTHERWISE Q) I JUNCTION BOX Q TIME CLOCK NOTES THIS DRAWING REPRESENTS THE GENERAL SCOPE OF THE PROJECT BUT DOES NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FJLL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. THE TRADE CONTRACTORS SHALL PERFORM SUCH SERVICES ABD FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION OF THE PROJECT. ANY DEVICES NOT SHODUN (I.E. FANS OR SPEAKERS) SHALL BE CENTERED IN CEILING TILES AND BETWEEN LIGHTS IN EACH DIRECTION. FOR SYMBOLS SHOWN IN THE LEGEND BUT DO NOT SHOW ON THE DRAWING MAY BE RELATED TO OTHER DISIPLINES AND MAY SHOW UP ON OTHER DRAWINGS. REFER TO THE MECHANICAL AND ELECTRICAL DRAWINGS. F— 7771 FMAITINGLY CORPORATION 10150 LANTERN ROAD, SUITE 100 FISHERS, INDIANA 46038 317 - 577 -9688 CONSTRUCTION DRAWINGS OCTOBER 11, 2002 REVISION& 1Q RRETSEI1N 2LREVISION DATE AREVISION A4 REVISION N A REVISION DA E N PLOT DATE: NA DRAWN BY- CHECKED BY D PETERSON PROJECT NUMBER 02 -0086 ELECTRICAL POWER PLAN E101 THESE DRAWINGS ARE GIVEN IN CONFIDENCE AND SHALL 5E USED ONLY IN PURSUANT TO THE AGREEMENT WITH PETERSON ARCHITECTURE, P.C. NO OTHER USE OR DUPLICATION MAY BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF PETERSON ARCHITECTURE, P.C. ALL OTHER COPYRIGHT AND COMMON LAW RIGHTS ARE HEREBY SPECIFICALLY RESERVED.