PLUMBING PLAN - SECOND FLOOR
SCALE: v8' = V -0'
PLUMBING PLAN -FIRST FLOOR
SCALE: 1/8' - 1' -0'
G
Tc
- - -W,
PLUMBING NOTES
THIS DRAWING FM - ESENTS THE GENERAL SCOPE OF THE PROJECT INT TERMS OF THE
PLUMBING DESIGN CONCEPT. IT DOES NOT NECESSARILY INDICATE OR DESCRIBE ALL
WORK REQUIRED FOR THE FULL PERFORMANCE AND /OR COMPLETION OF THE CONTRACT.
THE TRADE CONTRACTORS SHALL PERFORM SUCH SERVICES AND FURNISH ALL ITEMS
RECUIRED FOR THE FULL AND PROPER EXECUTION OF THE PROJECT.
EXISTING SANITARY LINES LOCATIONS SHOWN ON THIS PLAN ARE ESTIMATED. ACTUAL
-LOCATIONS FOR ANY UTILITIES DUST BE VERIFIED IN THE HELD.
MATERIALS:
L PIPE AND DUCT HANGERS SHALL BE UNISTRUCT 2000 WITH 3/8' RODS AND LITCHFIELD CLIC
SYSTEMS 316 S.S. ACCESSORIES, CLIC PIPE SUPPORT CLAMPS OR UNI- CUSHION CLAMPS. SIZE
OF CLAMPS SHALL BE DETERMINED BY THE MANUFACTURER BASED ON THE TYPE AND LOAD
OF EACH SYSTEM.
2. ALL WATER PIPING- SHALL BE TYPE 'L' COPPER ASTM 8 -88 HARD WITH ANSI 81622 WROUGHT
COPPER FITTINGS AND NON -LEAD SOLDERED JOINTS. UNDERGROUND PIPING SHALL BE TYPE 'K'
SOFT ASTM 5-88 WITH NO JOINTS AND ROLLED RADIUS TURNS UN- KINKED.
3. ALL GAS SHALL BE SCHEDULE 40 ASTM A- 12063 WITH MALLEABLE IRON 125 IB. FITTINGS. ALL
JOINTS SHALL BE TEFLON TAPE AND PIPING CAULKED.
4. ALL SANITARY SEWER SHALL BE CAST IRON SCHEDULED 40 HOLES$ CISPI STANDARD 301 -18 OR
SCHEDULE 40 PVC ASTM 0-2665. ANY PIPING LOCATED EXPOSED OR IN A RETURN AIR PLENUM
SPACE SHALL BE CAST IRON. VENT PIPING SHALL BE THE SAME MATERIAL AS SANITARY SEWER
5. VALVES SHALL BE OF THE TYPE AND DESIGN FOR SERVICES BEING USED.
BALL - BRONZE BODY 125 LB, WOG NIBCO T OR 5 -580Y.
GATE - OR 5 -111.
GLOBE - OR 5 -211.
CHECK - OR 5- 413 -5.
GAS COCKS - OR NORDSTROM 142.
OTHER APPROVED MANUFACTURERS ARE APOLLO, STICKHAM, GRIMNELL, HAMMOND, WALWORTH,
LUNKENHEIMER, CRANE OR MILWAUKEE (OR APPROVED EQUAL).
6. INSULATION FOR PIPING SYSTEMS SHALL BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS
AND RECOMMENDED INSTALLATION PROCEDURES.
WATER LINES - 1/2' CLOSED CELLED FOAM BY HALSTEAD OR ARMAFLEX FM
STORM SEWER - SAME AS ABOVE.
CONDENSATE SHALL BE 3/4' FOERSLASS - SAME AS ABOVE.
A: INSULATE ALL WATER LINES COLD AND HOT, AND ALL HORIZONTAL STORM SEWER PIPING.
B: ALL INSULATION SHALL HAVE A GALVANIZED SLEEVE WHEN RESTING ON THE ANY OTHER
BUILDING MATERIAL.
1. ANY EXPOSED PIPING SHALL HAVE A CHROME ESCUTCHEON PLATE WHERE EXPOSED IN FINISH
ROOMS. ALL PIPES THAT PASS THROUGH A FIRE WALL SHALL BE CAULKED AROUND PENETRATION
WITH A FLAME RETARDANT UL SEALANT TO MAINTAIN RATING ON WALL. SILICONE CAULK ALL
FIXTURES AROUND PERIMETER AFTER FINAL PAINTING OF WALLS.
8. ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED FOR 24 HOURS BEFORE FINAL CONNECTION
TO EXISTING IN ACCORDANCE WITH CODES.
S. ALL FIXTURES SHALL BE AS SHOWN ON THE DRAWINGS AS TO TYPE AND MATERIALS BY ELJER,
KOHLER, CRANE, AMERICAN STANDARD, ZURN, WADE, JOSAM, DELANY, SLOAN, PRICE, MOEN, POWERS,
SPEAKMAN, CHICAGO FAUCET, BEMIS, OLSONITE, FIAT (OR APPROVED EQUAL).
10. COORDINATE W/EQUIPMENT SUPPLIER FOR REQUIRED V AIR GAPS FOR EQUIPMENT
W/ A CONDENSER UNIT.
r --- 5
3' W.
3' W.
3' VENT
THRU ROOF
PLUMBING RISER
NO SCALE
3' VENT
THRU ROOF
CONNECT TO
EXISTING WASTE
PIPING
wMATTINGLY
CORPORATION
10150 LANTERN ROAD, SUITE 100
FISHERS, INDIANA 46038
317 - 577 -9688
CONSTRUCTION DRAWINGS
OCTOBER 11, 2002
REVISION&
A REVISION
REVISION
2 DATE
QR ISSION
REVISION
4 DATE
5 QREVISION
DATE
PLOT DATE: NA
DRAWN BY-
CHECKED BY D PETERSON
PROJECT NUMBER: 02 -0086
PLUMBING
FLOOR PLAN
Plol
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
AND SHALL BE USED ONLY IN PURSUANT TO THE
AGREEMENT WITH
PETERSON ARCHITECTURE, P.C.
NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT THE PRIOR WRITTEN CONSENT OF
PETERSON ARCHITECTURE, P.C.
ALL OTHER COPYRIGHT AND COMMON LAW
RIGHTS ARE HEREBY SPECIFICALLY RESERVED.