HomeMy WebLinkAbout04110041.60
_
a~
_
-7,i
BULKHEAD HT.
+ 8' -4 I I I I I I I I
w
0
Q
>w
+
1 107 1
102
� BULKHEAD HT.
IF +11-01
+
oL BULKHEAD HT.
+1 -0
OL BULKHEAD HT.
+1 -0
101
�
ILI co
CEILING PLAN - FIRST FLOOR.
SCALE: 1/4' - 1' -0'
SYMBOLS LEGEND
O2'x4' RECESSED FLUORESCENT LIGHT FIXTURE WITH ENERGY
SAVING LAMPS (31 W) AND HIGH EFFICIENCY BALLAST.
0 I RECESSED INCANDESCENT EYEBALL LIGHT FIXTURE.
SURFACE MOUNTED FLUORESCENT EXPOSED BULB LIGHT
I
EMERGENCY LIGHT WITH LIGHTED EXIT SIGN MOUNTED IS' BELOW
FINISHED CEILING LEVEL, UNLESS NOTED OTHERWISE.
EMERGENCY LIGHT WITH BATTERY BACK -UP. VERIFY FINAL
LOCATION WITH OWNER (TYPICAL).
EXIT SIGN WITH BATTERY BACK-UP. VERIFY FINAL
LOCATION WITH OWNER
®SUPPLY AIR DIFFUSER REFER TO MECHANICAL DRAWINGS
FOR SIZE AND LOCATION. (TYPICAL).
IRETURN AIR GRILL. REFER TO MECHANICAL DRAWINGS FOR
SIZE AND LOCATION. (TYPICAL).
f I SINGLE POLE SWITCH 2OA -120V a 4' -0' AFF,
®TOILET AREA SUPPLY AIR DIFFUSER REFER TO MECHANICAL
DRAWINGS FOR SIZE AND LOCATION. (TYPICAL).
® I CEILING MOUNTED EXHAUST FAN
NOTES
THIS DRAWING REPRESENTS THE GENERAL SCOPE OF THE
PROJECT. IT DOES NOT NECESSARILY INDICATE OR DESCRIBE
ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND /OR
COMPLETION OF THE CONTRACT. THE TRADE CONTRACTORS
SHALL PERFORM SUCH SERVICES AND FURNISH ALL ITEMS
REQUIRED FOR THE FULL AND PROPER EXECUTION OF THE PROJECT.
ANY DEVICES NOT SHOWN (IF. - FANS OR SPEAKERS) SHALL
BE CENTERED IN CEILING TILES AND BETWEEN LIGHTS IN
EACH DIRECTION.
SYMBOLS SHOWN IN THE LEGEND BUT NOT SHOWN ON THIS
DRAWING MAY BE RELATED TO OTHER DISCIPLNES AND MAY
SHOW ON OTHER DRAWINGS. REFER TO THE MECHANICAL
AND ELECTRICAL DRAWINGS.
PET
%�� ���y1STfRf• F/P ��i
?o No. :y=
* AR19500143
VAIE W
P E T E R S 0 N
ARCHITECTURE
984 Logan Street Suite 10 Noblesville, IN 48080 USA
t e 1 31 7 7 7 0 9 71 4
f a x 3 1 7 7 7 0 9 7 1 8
email atadio4peteraonarchitectnre.com
wMATTINGLY
CORPORATION
10150 LANTERN ROAD, SUITE 100
FISHERS, INDIANA 46038
317 - 577 -9688
CONSTRUCTION DRAWINGS
FEBURARY 19, 2002
REVISION&
QRD TSION
REVISION
2 DATE
REVISION
3 DATE
REVISION
4 DATE
AREVISION
N
PLOT DATE: NA
DRAWN BY: W WILLIAMS
CHECKED BY- R MCGILL
PROJECT NUMBER: 02 -0086
REFLECTED
CEILING PLANS
A103
THE5E DRAWINGS ARE GIVEN IN CONFIDENCE
AND 5HALL BE USED ONLY IN PURSUANT TO THE
AGREEMENT WITH
PETERSON ARCHITECTURE, P.C.
NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT THE PRIOR WRITTEN CONSENT OF
PETERSON ARCHITECTURE, P.C.