HomeMy WebLinkAboutSS 51 Site Plan.pdf' Grou
La� n d S u rveyo rs
494 Gradle Drive Phone: 317.844.3333
Carmel, IN 46032 Fax: 317.844.3383
www.SEAGroupLLC.com
00.0 PROPOSED GRADE PER PLAN
� GROUND WATER FLOW
-�+ �+ - SANITARY SEWER LINE
-sn� sn� - STORM SEWER LINE
-� � - WATER LINE
---------------- EASEMENT LINE
- - - - BUILDING SETBACK LINE
�
THIS PLOT PLAN WAS
PREPARED BASED ON
INFORMATION TAKEN FROM
RECORD PLATS, SUBDIVISION
PLANS, RECORD DRAWINGS
AND PLANS PROVIDED BY
CLIENT. IT IS THE
RESPONSIBILITY OF THE
CONTRACTOR TO VERIFY SITE
CONDITIONS PRIOR TO
CONSTRUCTION AND NOTIFY
THE S E A GROUP OF ANY
DISCREPANCIES.
LOT# 51
15,00o S.F. MINIMUM SETBACKS
MIN. SIDE YARD = 5.0 Feet
MIN. REAR YARD = 30 Feet
Aaa. = 15 Feet between structures
SAN. STR. (816)
SAN. STR. (815) TC=906.35
TC=905.35 PER PLAN
O PER PLAN
sur sw su� �sw Tsa� su+ s�w sw su+ su+ -
I
� �
- - - - - - - - - - - - - - - - - - - - -
CURB
HOMESTRETCH DRIVE � �
50' R/W
CURB � � PRON
A
wm wrtt
904.9 ,
\� 90 ��42)
N
��
904.00
WALK
Z~ I
�J�'
�Z �
¢
25' D.dcU.E. � N I
3
----�-------- --� -T
POR. � � � � S%+
I 908.0 �„ ;�O•�„
19.0' � 12.33' 08.67'O- �y0 °
�• o "�
� N PROPOSED
� 5.0' O1 FRM & MSY
� � °o RESIDENCE
� � FFE=909.7f
I
O �
� � .00'°' e� Tass.�t
� .00 0
17.0' I O1 �2.46� � h�`
903.50 � �''-w 15.00�''•+1.87r'�rtS,�' �
� �
i 908.0 �' � 8.61'
I
I �
I
I
v
�
�
�
0
�
z
N N J
��a
� U W
rn t- a
� �
�
�
�
�
�
i 905.00
�ow uNe o�
wm �
� ��. ��' 905.30
�� SUMP 4.0'
CONNECTION
v �2.0'
10' MIN.
- WA------ --
30' B.S.L 906.50
908.0 8
21.66' 1.0'
� 2a.o'
GARAGE
� FFE=908.4t 25.0'
� �
I coNc
w DRIVE
L-__ 6 a4.0'
0 1.0'
�
21.67' o°�
906.00
PORCH
10' PATIO
0' �7
O
� O
�
oo.00� 15' D.E.
904.30
STORM STR. (744)
TC=903.00
PER PLAN
Property Description:
Lot Number 51 in Saddlebrook at Shelbourne,
Section Two, an Addition in Hamilton County,
Indiana, as per plat thereof recorded as
Instrument Number 2006074226 found in the
Office of the Recorder of Hamilton County,
Indiana.
PLOT PLAN
Scale: 1 "=30'
Date: Feb. 7, 2013
Drawn by: DJR
Revised:
N OTE:
BUILDER TO MAINTAIN A 10'
SEPARATION BETWEEN WATER
AND SANITARY LATERALS.
NOTE:
SUMP TO BE PLACED BY
BUILDER AS NEEDED.
LOCATION OF UTILITY
LATERALS ON PLOT PLAN
ARE GENERAL LOCATIONS
PER PLAN AND SHOULD BE
VERIFIED IN THE FIELD.
NOTE:
BUILDER TO ENSURE POSITIVE
FLOW AWAY FROM
STRUCTURE.
--- ��.�`���GRAIG��Rjsi,
�'
��
`� � ,��G1STEj�iFO�l���i
` :'P�� No. '�'
'� ��: : �i
�m : : ��
\= * � LS20200083 � * =
- : : -
_ . . -
. . . -
� ; STATE OF • �
�`q�� �NDIANP•�:0�``�
�����i�� �SURV` ���``��
���������
Prepared For:
Homes by Rex Brown
Residence
3219 Homestretch Drive